2882585 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2882585
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Surge protection in the IP67 screw-on module for measuring sensors in intrinsically safe circuits, direct mounting with 3/4" NPT outer thread, cable gland for the signal cable, two-stage protective circuit. HART-compatible.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2882585 Phoenix Contact price in the box on the right side or send a quick quote.
2882585 Product Details
- Degree of protection IP67
- max. input power Pi 3 W
- IEC test classification C1
- Nominal discharge current In (8/20) µs (shield-earth) 10 kA (optional)
- Output voltage limitation at 1 kV/µs (line-line) spike ≤ 50 V
- Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 1.4 kV (Direct grounding)
- Residual voltage at In (line-line) ≤ 50 V
- Input attenuation aE, sym. typ. 0.5 dB (≤ 1 MHz / 50 Ω)
- Resistance per path 2.2 Ω ±10 %
- Impulse durability (line-earth) C1 - 1 kV / 500 A
- Conductor cross section solid 0.14 mm² ... 1.5 mm²
- REACh SVHC Lead 7439-92-1
- IECEx Ex ia IIC T4...T6 Ga
- ECLASS 4.0 27130800
- Height 33.5 mm
- Maximum inner capacitance Ci 2 nF
- Max. input current Ii 350 mA (T4 / ≤ 50 °C)
- Rated current 350 mA (50 °C)
- Ambient temperature (operation) -40 °C ... 50 °C
- Max. internal inductance Li 1 µH
- Maximum continuous voltage UC 30 V DC
- Nominal discharge current In (8/20) µs (line-earth) 10 kA (per path)
- Depth 148 mm
- Max. input voltage Ui 30 V
- Residual current IPE ≤ 2 µA
- Nominal pulse current Ian (10/1000) µs (line-line) 30 A
- Output voltage limitation at 1 kV/µs (line-line) static ≤ 50 V
- Voltage protection level Up (line-line) ≤ 50 V (C1 - 0.5 kV / 250 A)
- Response time tA (line-line) ≤ 1 ns
- Impulse durability (line-line) C1 - 1 kV / 500 A
- Connection technology Screw connection
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27130800
- ETIM 6.0 EC000943
- UNSPSC 11 39121610
- UNSPSC 20.0 39121620
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal voltage UN 24 V DC
- Nominal discharge current In (8/20) µs (line-line) 10 kA
- Max. discharge current Imax (8/20) µs maximum (shield-earth) 10 kA
- Pulse discharge current Iimp (10/350) µs 1 kA
- Voltage protection level Up (shield-earth) ≤ 600 V (C1 - 0.5 kV / 250 A)
- Response time tA (line-earth) ≤ 100 ns
- Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 2.5 MHz
- Alternating current carrying capacity (shield-earth) 10 A - 1 s
- Conductor cross section flexible 0.14 mm² ... 1.5 mm²
- ATEX II 1G Ex ia IIC T4...T6 Ga
- ECLASS 7.0 27130807
- ETIM 3.0 EC000943
- UNSPSC 18.0 39121620
- Output voltage limitation at 1 kV/µs (shield-earth) spike ≤ 600 V (optional)
- Response time tA (shield-earth) ≤ 100 ns
- Connection method IN Screw terminal blocks
- Connection method OUT Connection line
- Screw thread M3
- Conductor cross section AWG 26 ... 16
- ECLASS 10.0.1 27130807
- ECLASS 4.1 27130800
- ETIM 4.0 EC000943
- ETIM 7.0 EC000943
- UNSPSC 7.0901 39121610
- UNSPSC 21.0 39121620
- Width 33.5 mm
- Altitude ≤ 2000 m (amsl (above mean sea level))
- Max. discharge current Imax (8/20) µs maximum (line-line) 10 kA
- Nominal pulse current Ian (10/1000) µs (line-earth) 100 A (per path)
- Output voltage limitation at 1 kV/µs (line-earth) static ≤ 1.4 kV (Direct grounding)
- Residual voltage with Ian (10/1000) µs (line-line) ≤ 50 V
- Surge protection fault message none
- Connection method Screw connection
- Stripping length 6 mm
- ECLASS 11.0 27130807
- ECLASS 9.0 27130807
- UNSPSC 12.01 39121610
- UNSPSC 19.0 39121620
- Insulation voltage to ground 500 V AC
- Operating effective current IC at UC ≤ 10 µA
- Max. discharge current Imax (8/20) µs maximum (line-earth) 10 kA (per path)
- Nominal pulse current Ian (10/1000) µs (shield-earth) 100 A
- Voltage protection level Up (line-earth) ≤ 1.4 kV (C1 - 1 kV/500 A)
- Cut-off frequency fg (3 dB), sym. in 50 Ω system typ. 6 MHz
- Alternating current carrying capacity (line-earth) 10 A - 1 s
- Impulse durability (shield-earth) C1 - 1 kV/500 A
- Tightening torque 0.6 Nm
- Standards/specifications EN 61643-21 A2:2013
- ECLASS 5.0 27130800
- ECLASS 5.1 27130800
- ETIM 2.0 EC000943
- UNSPSC 6.01 30212010
- UNSPSC 13.2 39121620
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2882585
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?