3270361 Phoenix Contact Terminal Blocks
Part#:3270361
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Marshalling patchboard, without actuation lever, nom. voltage: 500 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 48, number of connections: 288, width: 66 mm, lengt
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3270361 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Result of power-frequency withstand voltage test Test passed
- Conductor cross section flexible max. 1.5 mm²
- Result of thermal test Test passed
- Setpoint 1 N
- Shock test result Test passed
- Number of connections 288
- Degree of pollution 3
- Nominal current IN 17.5 A
- ECLASS 10.0.1 27141120
- ECLASS 4.0 27141100
- ETIM 7.0 EC000897
- ECLASS 9.0 27141120
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 5.1 27141100
- UNSPSC 13.2 39121410
- UNSPSC 19.0 39121410
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Surface flammability NFPA 130 (ASTM E 162) passed
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 11.0 27141120
- ECLASS 7.0 27141120
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 6.0 27141100
- ECLASS 5.0 27141100
- UNSPSC 18.0 39121410
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.1 27141100
- ETIM 6.0 EC000897
- UNSPSC 20.0 39121410
- UNSPSC 21.0 39121410
- Rated surge voltage 6 kV
- Finger protection guaranteed
- Bending test rotation speed 10 rpm
- Result of temperature-rise test Test passed
- Result of aging test Test passed
- Conductor cross section short circuit testing 2.5 mm²
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 30 ms
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 111 mm
- Conductor cross section AWG min. 26
- Nominal cross section 1.5 mm²
- Insulating material PA
- Overvoltage category III
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of surge voltage test Test passed
- Bending test turns 135
- Result of flexion and pull-out test Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Short-time current 0.3 kA
- Oscillation, broadband noise test result Test passed
- Acceleration 5g
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Number of shocks per direction 3
- Height 30 mm
- Connection in acc. with standard IEC 60947-7-1
- Min. AWG conductor cross section, flexible 26
- Connection cross sections directly pluggable 0.34 mm² 2.5 mm² 20 14
- Note The max. load current must not be exceeded by the total current of all connected conductors.
- Color of connection elements blue
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 1.89 kV
- Result of tight fit on support Test passed
- Tight fit on carrier NS 35
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Width 66 mm
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section solid min. 0.34 mm²
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm²
- Number of levels 1
- Flammability rating according to UL 94 V0
- Nominal voltage UN 500 V
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Tensile test result Test passed
- Short circuit stability result Test passed
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- ASD level 0.964 (m/s2)2/Hz
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Stripping length 8 mm ... 10 mm
- Conductor cross section solid max. 2.5 mm²
- Max. AWG conductor cross section, flexible 14
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Number of positions 48
- Color gray
- Insulating material group I
- Maximum power dissipation for nominal condition 0.56 W
- Maximum load current 24 A (in case of a 2.5 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
- Open side panel No
- Result of voltage-drop test Test passed
- Ageing test for screwless modular terminal block temperature cycles 192
- Test spectrum Service life test category 1, class B, body mounted
- Shock form Half-sine
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section AWG max. 14
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Internal cylindrical gage A1
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.