Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

2856032 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2856032 PT protective connector with protective circuit for a 2-wire floating signal circuit. HART-compatible.
Phoenix Contact

Part#:2856032

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 47

Apr 26, 2024

About the product: PT protective connector with protective circuit for a 2-wire floating signal circuit. HART-compatible.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2856032 Phoenix Contact price in the box on the right side or send a quick quote.

2856032 Product Details

  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 40 V
  • Voltage protection level Up (line-line)
    ≤ 70 V (C1 - 1 kV/500 A)
  • Input attenuation aE, sym.
    typ. 0.5 dB (≤ 1 MHz / 50 Ω)
  • Response time tA (line-line)
    ≤ 1 ns
  • Resistance per path
    2.2 Ω ±10 %
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Horizontal pitch
    1 Div.
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Overvoltage category
    II
  • Rated current
    450 mA (45 °C)
  • Residual current IPE
    ≤ 1 µA (with PT 1X2+F-BE)
  • Screw thread
    M3
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 9.0
    27130807
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620
  • Nominal discharge current In (8/20) µs (line-line)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 45 V
  • Residual voltage at In (line-line)
    ≤ 40 V
  • Voltage protection level Up static (line-line)
    ≤ 40 V (C2 - 10 kV / 5 kA)
  • Cut-off frequency fg (3 dB), sym. in 600 Ω system
    typ. 600 kHz
  • Surge protection fault message
    none
  • Connection method
    Screw connection (in connection with the base element)
  • Depth
    52 mm
  • Complete module depth
    65.5 mm
  • Housing material
    PA 6.6
  • Degree of pollution
    3
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Nominal voltage UN
    24 V DC
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27130800
  • ECLASS 6.0
    27130800
  • UNSPSC 6.01
    30212010
  • UNSPSC 19.0
    39121620
  • Operating effective current IC at UC
    ≤ 5 µA
  • Max. discharge current Imax (8/20) µs maximum (line-line)
    10 kA
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    10 kA
  • Width
    17.7 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 25 V (with PT 1X2-BE)
  • Response time tA (line-earth)
    ≤ 100 ns
  • ETIM 6.0
    EC000943
  • ETIM 4.0
    EC000943
  • UNSPSC 18.0
    39121620
  • Flammability rating according to UL 94
    V-0
  • Type
    Male
  • IEC test classification
    C1
  • Height
    45 mm
  • Complete module width
    17.7 mm
  • Pulse discharge current Iimp (10/350) µs
    2.5 kA
  • Nominal pulse current Ian (10/1000) µs (line-line)
    30 A
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 50 V
  • Voltage protection level Up static (line-earth)
    ≤ 50 V (C2 - 10 kV / 5 kA with PT 1X2-BE)
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 1.5 MHz
  • Capacity (line-earth)
    typ. 4 pF (with PT 1X2-BE)
  • Max. required back-up fuse
    500 mA (T)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Tightening torque
    0.5 Nm
  • ECLASS 10.0.1
    27130807
  • ECLASS 7.0
    27130807
  • ETIM 2.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 20.0
    39121620
  • Note
    Technical data is valid in association with the following specified base elements:
  • ECLASS 4.1
    27130800
  • Complete module height
    90 mm
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 450 V (with PT 1X2-BE)
  • Voltage protection level Up (line-earth)
    ≤ 450 V (C1 - 1 kV / 500 A with PT 1X2-BE)
  • Cut-off frequency fg (3 dB), sym. in 50 Ω system
    typ. 4.5 MHz
  • Capacity (line-line)
    typ. 1.4 nF
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Stripping length
    8 mm
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27130800
  • ECLASS 5.0
    27130800
  • ETIM 3.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 21.0
    39121620
  • Degree of protection
    IP20
  • Color
    jet black RAL 9005
  • UNSPSC 11
    39121610
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Maximum continuous voltage UC
    28 V DC
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Mounting type
    on base element
  • Arrester can be tested with CHECKMASTER from software version:
    From SW rev. 1.00

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$211.00

2856032

Stock:

47

Select Qty:

$211.00

$211.00 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo