About the product: Axioline Smart Elements, IO-Link master, 4 IO-Link ports, degree of protection: IP20
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 1088132 Phoenix Contact price in the box on the right side or send a quick quote.
1088132 Product Details
- Height 62.2 mm
- Conductor cross section AWG max. 16
- Caption Dimensions
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection IP20
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 62 mm
- Designation IO-Link
- Conductor cross section flexible min. 0.25 mm²
- Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
- Start time until ready to operate < 500 ms (after switching on the supply voltage (object 003Dhex: WakeUpTime))
- Nominal input voltage UIN 24 V DC
- Ambient temperature (operation) -25 °C ... 60 °C
- Connection method Push-in connection
- Conductor cross section solid min. 0.25 mm²
- Conductor cross section AWG min. 24
- Transmission speed See system in which you use the Smart Element.
- Port type Class A
- Test section Communications supply / 24 V supply (I/O) 500 V AC 50 Hz 1 min.
- Number of inputs max. 4 (EN 61131-2 type 1)
- Nominal input current typ. 2.5 mA
- Number of ports 4
- Nominal current per channel 200 mA
- Mounting type Smart Element slot
- Mounting position See the system in which the Smart Element is used.
- Width 14.9 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Number 1
- Connection technology 2-, 3-conductor
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Input filter time 1 µs
- Supply voltage range 18 V DC ... 30 V DC (including all tolerances, including ripple)
- Net weight 35 g
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section solid max. 1.5 mm²
- Description of the input IO-Link ports in digital input (DI) mode
- Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
- Input voltage range "0" signal -0.3 V DC ... 5 V DC
- Nominal voltage for I/O supply 24 V DC
- Number of outputs max. 4
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Overvoltage category II (IEC 60664-1)
- ECLASS 10.0.1 27242608
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline Smart Elements” user manual.
- Conductor cross section flexible max. 1.5 mm²
- Degree of pollution 2 (EN 60664-1)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- China RoHS Environmentally Friendly Use Period = 50 years
- Nominal current for every IO-Link port 500 mA (at L+/L-)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Stripping length 8 mm
- Output description IO-Link ports in digital output (DO) mode
- Color traffic grey A RAL 7042
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- ECLASS 11.0 27242608
- Sensor current per channel max. 500 mA (from L+/L-)
- Nominal output voltage 24 V DC
- Type of protection Overload protection for L+
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- REACh SVHC Lead 7439-92-1
- ECLASS 9.0 27242608
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨