1088130 Phoenix Contact Programmable Logic Controllers
Part#:1088130
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 130
Nov 21, 2024
Axioline Smart Elements, Position detection module, Incremental encoder input: 1, symmetrical encoders, in accordance with EIA-422, Digital inputs: 2, 24 V DC, degree of protection: IP20
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1088130 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 11.0 27242605
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 62 mm
- Color traffic grey A RAL 7042
- Transmission speed See system in which you use the Smart Element.
- Power consumption min. 264 mW
- Nominal output voltage 24 V DC
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Common mode voltage range signal - ground -20 V DC ... 20 V DC
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Net weight 35 g
- Number 1
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Protection See the system in which the Smart Element is used.
- Encoder signals symmetrical encoders, in accordance with EIA-422
- Type of protection Short-circuit protection
- Voltage range 19.2 V DC ... 30 V DC
- Nominal input voltage UIN 24 V DC
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- China RoHS Environmentally Friendly Use Period = 50 years
- Width 14.9 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Mounting type Smart Element slot
- Designation Symmetrical incremental encoders
- Start time until ready to operate < 500 ms (after switching on the supply voltage (object 003Dhex: WakeUpTime))
- Current consumption min. 11 mA (without connected peripherals)
- Number of inputs 2 (DI Ref, DI L)
- Number of 5 V encoder supplies 1 (+5 V)
- Cable length < 30 m (Shielded cable)
- Signal voltage level Differential signal (signal – inverted signal), in accordance with EIA-422
- Input frequency max. 1 MHz
- Nominal input current at UIN 3 mA
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- REACh SVHC Lead 7439-92-1
- Supply voltage 24 V DC (using card edge connectors)
- Protective circuit Transient protection Suppressor diode
- Current carrying capacity max. 500 mA
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242605
- Height 62.2 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Degree of pollution 2 (EN 60664-1)
- Connection method Push-in connection
- Description of the input EN 61131-2, type 3
- Encoder types that can be connected 1 (A, /A, B, /B, Z, /Z)
- Test section Communications supply / 24 V supply (I/O) 500 V AC 50 Hz 1 min.
- Degree of protection IP20
- Mounting position See the system in which the Smart Element is used.
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, shielded I/O cables: ±1 kV asymmetrical
- Overvoltage category II (IEC 60664-1)
- ECLASS 9.0 27242605
- Caption Dimensions
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Additional text using card edge connectors
- Input name Digital inputs
- Number of 24 V encoder supplies 1 (+24 V)
- Connection technology 1-conductor
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$263.59
Stock:
130
Select Qty:
$263.59
$263.59 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.