1088728 Phoenix Contact Terminal Blocks
Part#:1088728
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 50
Nov 21, 2024
Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, connection method: Push-in connection, number of connections: 2, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, height: 35.3 mm, color: gray, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1088728 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Color gray
- Number of connections 2
- Maximum load current 36 A (with 6 mm² conductor cross section, rigid)
- Back of the hand protection guaranteed
- Result of power-frequency withstand voltage test Test passed
- Potentials 1
- Overvoltage category III
- Insulating material group I
- Nominal voltage UN 1000 V
- Surge voltage test setpoint 9.8 kV
- Bending test conductor cross section/weight 0.2 mm² / 0.2 kg
- Conductor cross section tensile test 6 mm²
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Test spectrum Service life test category 2, bogie-mounted
- Test duration per axis 5 h
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Width 6.2 mm
- Height 35.3 mm
- Conductor cross section solid min. 0.75 mm²
- Conductor cross section flexible max. 6 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm²
- Connection cross sections directly pluggable 0.75 mm² 6 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 5.0 27141100
- ECLASS 5.1 27141100
- ETIM 7.0 EC000897
- UNSPSC 7.0901 39121410
- Number of levels 1
- Flammability rating according to UL 94 V0
- Nominal current IN 32 A
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of surge voltage test Test passed
- Result of flexion and pull-out test Test passed
- Result of voltage-drop test Test passed
- Conductor cross section short circuit testing 4 mm²
- Ageing test for screwless modular terminal block temperature cycles 192
- Shock test result Test passed
- Shock duration 18 ms
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 1.5 mm²
- Internal cylindrical gage A4
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 4.1 27141100
- ETIM 6.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 21.0 39121410
- Nominal cross section 4 mm²
- Area of application Railway industry
- Maximum power dissipation for nominal condition 1.02 W
- Open side panel Yes
- Power frequency withstand voltage setpoint 2.2 kV
- Tensile test result Test passed
- Result of temperature-rise test Test passed
- Short-time current 0.48 kA
- Oscillation, broadband noise test result Test passed
- ASD level 6.12 (m/s2)2/Hz
- Shock form Half-sine
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 50.8 mm
- Height NS 35/15 44.3 mm
- Stripping length 9 mm ... 11 mm
- Conductor cross section AWG min. 24
- Min. AWG conductor cross section, flexible 24
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 10.0.1 27141120
- ECLASS 9.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 19.0 39121410
- Insulating material PA
- Degree of pollution 3
- Rated surge voltage 8 kV
- Finger protection guaranteed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test turns 135
- Tractive force setpoint 80 N
- Result of thermal test Test passed
- Result of aging test Test passed
- Acceleration 30g
- Number of shocks per direction 3
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height NS 35/7,5 36.8 mm
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section AWG max. 10
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.0 27141100
- ECLASS 7.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 18.0 39121410
- Bending test rotation speed 10 rpm
- Result of tight fit on support Test passed
- Short circuit stability result Test passed
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- End cover width 2.2 mm
- Connection 1 level
- Conductor cross section solid max. 6 mm²
- Max. AWG conductor cross section, flexible 10
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 1.5 mm²
- ECLASS 11.0 27141120
- ECLASS 6.0 27141100
- ETIM 2.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 20.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$2.42
Stock:
50
Select Qty:
$2.42
$2.42 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨