1050252 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:1050252
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, standard configurati
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1050252 Phoenix Contact price in the box on the right side or send a quick quote.
1050252 Product Details
- Width 12.5 mm
- Degree of protection IP20
- Sensor types (RTD) that can be used Sensors (2-, 3-, 4-conductor)
- Configurable/programmable Yes
- Output ripple (current) < 15 µAPP
- Power dissipation ≤ 0.76 W
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Step response (0–99%) typ. 1 s
- Conductor cross section AWG 24 ... 16
- Alignment span ± 5 %
- Designation EAC Ex
- Max. output current Io 400 mA
- Input current Ii 100 mA
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Ambient temperature (operation) 49 °C
- Rated insulation voltage 300 Vrms
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Signal output Current output
- Current output signal 0 mA ... 20 mA
- Power consumption ≤ 1 W
- Noise emission EN 61000-6-4
- Additional text and EN 61326
- Sensor input current 10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
- Behavior in the event of a sensor error As per NE 43 or can be freely defined
- Connection method Push-in connection
- No. of channels 1
- Height 116 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Temperature measuring range -200 °C ... 850 °C (Range depending on the sensor type)
- Alignment zero ± 5 %
- Color gray
- Degree of pollution 2
- Group IIC/IIB/IIA
- Typical deviation from the measuring range final value 1 %
- Input power Pi 550 mW
- DNV GL-Temperature B
- Input voltage Ui 7 V
- Depth 114.5 mm
- Input signal range 0 Ω ... 50 kΩ
- Load/output load current output ≤ 600 Ω
- Nominal supply voltage 24 V DC
- Stripping length 8 mm
- Temperature coefficient, typical 0.01 %/K
- Interference emission EN 61000-6-4
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. output voltage Uo 3.5 V
- Max. external capacitance Co 2 µF
- IECEx [Ex ia Ma] I
- DNV GL-EMC B
- Temperature B
- ECLASS 11.0 27210129
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27210120
- ETIM 3.0 EC001446
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Altitude ≤ 5000 m
- Max. permissible overall conductor resistance 50 Ω (Per cable)
- Measuring range span ≥ 50 K
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Transmission error, typical 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Electromagnetic compatibility Conformance with EMC directive
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Max. output power Po 350 mW
- Conformance CE-compliant, additionally EN 61326
- DNV GL-Vibration A
- Vibration A
- ECLASS 10.0.1 27210129
- ETIM 2.0 EC001446
- UNSPSC 6.01 30211506
- Status display Green LED (supply voltage, PWR)
- Housing material PA 6.6-FR
- Overvoltage category II
- Max. internal capacitance Ci 47 µF
- Max. external inductivity Lo 20 µH
- Safety-related maximum voltage Um 253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC)
- Standards/regulations GB 3626.20
- ATEX I (M1) [Ex ia Ma] I
- DNV GL-Humidity B
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Certificate RU C-DE.AB72.B.00093/19
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.0 27210120
- ECLASS 9.0 27210129
- ETIM 4.0 EC001446
- UNSPSC 12.01 39121008
- UNSPSC 19.0 41112105
- UNSPSC 7.0901 39121008
- UNSPSC 11 39121008
- ECLASS 5.0 27210120
- ETIM 7.0 EC002919
- UNSPSC 20.0 41112105
- EMC B
- ECLASS 6.0 27210120
- UNSPSC 21.0 41112105
- Humidity B
- Identification [Ex ia Ga] IIC
- UNSPSC 18.0 41112105
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27210120
- UNSPSC 13.2 41112105
- ECLASS 4.1 27210120
- ETIM 6.0 EC002919
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
1050252
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨