Pepperl + Fuchs KFD2-UT2-EX2 Universal Temperature Converter, 2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configura
Pepperl + Fuchs

Part#:KFD2-UT2-EX2

Manufacturer:Pepperl + Fuchs

Product Lifecycle:Active

Get a quick Quote!

Universal Temperature Converter, 2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configura

Check out the KFD2-UT2-EX2 Pepperl + Fuchs price in the box on the right side or send a quick quote.

Product Details

  • Supplementary information
    Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
  • IECEx marking
    [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I, Ex nA IIC T4 Gc
  • Control drawing
    116-0410
  • Input/Other circuits
    safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
  • Directive 2014/34/EU
    EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000
  • IECEx certificate
    IECEx TUN 07.0003, IECEx CML 16.0126X
  • Power Po
    50 mW
  • Certificate
    TÜV 02 ATEX 1797 X
  • Maximum safe voltage
    250 V (Attention! This is not the rated voltage.)
  • Voltage Uo
    9 V
  • Inputs
    terminals 1, 2, 3, 4, 5, 6 (for passive equipment)
  • Dimensions
    20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
  • EU-type examination certificate
    CESI 04 ATEX 143
  • Current Io
    22 mA
  • Mounting
    on 35 mm DIN mounting rail acc. to EN 60715:2001
  • Marking
    Ex-HexagonII (1)G [Ex ia Ga] IIC, Ex-HexagonII (1)D [Ex ia Da] IIIC, Ex-HexagonI (M1) [Ex ia Ma] I
  • Input
    Ex ia
  • Protection against electrical shock
    UL 61010-1:2004
  • Mass
    approx. 130 g
  • Ambient temperature
    -20 ... 60 °C (-4 ... 140 °F)
  • Degree of protection
    IEC 60529:2001
  • Electromagnetic compatibility
    NE 21:2006
  • Influence of supply voltage
    < 0.01 % of span
  • Output/supply, programming input
    functional insulation, rated insulation voltage 50 V AC, There is no electrical isolation between the programming input and the supply., The programming cable provides galvanic isolation so that ground loops are avoided.
  • Configuration
    via PACTware
  • Directive 2014/30/EU
    EN 61326-1:2013 (industrial locations)
  • Labeling
    space for labeling at the front
  • Reaction time
    worst case value (sensor breakage and/or sensor short circuit detection enabled), mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-w
  • Influence of ambient temperature
    Pt100:± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*), thermocouple:± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compe
  • Display elements
    LEDs
  • Influence of load
    ≤ 0.001 % of output value per 100 Ω
  • After calibration
    Pt100:± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)), thermocouple:± (0.05 % of measurement value in °C + 0.1 % of span + 1 K (1.2 K for types R and S)) , includes ± 0.8 K fault of the cold junction compensa
  • Output I, II
    Analog current output
  • Cold junction compensation
    external and internal
  • Source
    load 0 ... 550 Ω, open-circuit voltage ≤ 18 V
  • Sink
    Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,, series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage., The maximum value of the resistance is (V - 5)/0.0215 Ω.
  • Fault signal
    downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
  • Current range
    0 ... 20 mA or 4 ... 20 mA
  • Input resistance
    ≥ 1 MΩ (-100 ... 100 mV)
  • Voltage
    selectable within the range -100 ... 100 mV
  • Potentiometer
    0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
  • Thermocouples
    type B, E, J, K, N, R, S, T (IEC 584-1: 1995), type L (DIN 43710: 1985), type TXK, TXKH, TXA (P8.585-2001)
  • Measurement loop monitoring
    sensor breakage, sensor short-circuit
  • Programming interface
    programming socket
  • Measuring current
    approx. 200 µA with RTD
  • RTD
    type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995), type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94), type Cu10, Cu50, Cu100 (P50353-92), type Ni100 (DIN 43760)
  • Ripple
    within the supply tolerance
  • Connection side
    field side
  • Power consumption
    max. 1.53 W
  • Types of measuring
    2-, 3-wire connection
  • Lead resistance
    max. 50 Ω per line
  • Power dissipation
    ≤ 1.53 W
  • Rated voltage
    20 ... 30 V DC
  • Safety Integrity Level (SIL)
    SIL 2
  • Connection
    terminals 14+, 15- or power feed module/Power Rail
  • Signal type
    Analog input

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents KFD2-UT2-EX2 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Pepperl + Fuchs

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Pepperl + Fuchs Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Pepperl + Fuchs Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Pepperl + Fuchs, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo