KFD2-UT2-EX2 Pepperl + Fuchs Electronic Components
Part#:KFD2-UT2-EX2
Manufacturer:Pepperl + Fuchs
Product Lifecycle:Active
Get a quick Quote!
Universal Temperature Converter, 2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configura
Check out the KFD2-UT2-EX2 Pepperl + Fuchs price in the box on the right side or send a quick quote.
Product Details
- Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
- IECEx marking [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I, Ex nA IIC T4 Gc
- Control drawing 116-0410
- Input/Other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
- Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000
- IECEx certificate IECEx TUN 07.0003, IECEx CML 16.0126X
- Power Po 50 mW
- Certificate TÜV 02 ATEX 1797 X
- Maximum safe voltage 250 V (Attention! This is not the rated voltage.)
- Voltage Uo 9 V
- Inputs terminals 1, 2, 3, 4, 5, 6 (for passive equipment)
- Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
- EU-type examination certificate CESI 04 ATEX 143
- Current Io 22 mA
- Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
- Marking II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
- Input Ex ia
- Protection against electrical shock UL 61010-1:2004
- Mass approx. 130 g
- Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
- Degree of protection IEC 60529:2001
- Electromagnetic compatibility NE 21:2006
- Influence of supply voltage < 0.01 % of span
- Output/supply, programming input functional insulation, rated insulation voltage 50 V AC, There is no electrical isolation between the programming input and the supply., The programming cable provides galvanic isolation so that ground loops are avoided.
- Configuration via PACTware
- Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
- Labeling space for labeling at the front
- Reaction time worst case value (sensor breakage and/or sensor short circuit detection enabled), mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-w
- Influence of ambient temperature Pt100:± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*), thermocouple:± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compe
- Display elements LEDs
- Influence of load ≤ 0.001 % of output value per 100 Ω
- After calibration Pt100:± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)), thermocouple:± (0.05 % of measurement value in °C + 0.1 % of span + 1 K (1.2 K for types R and S)) , includes ± 0.8 K fault of the cold junction compensa
- Output I, II Analog current output
- Cold junction compensation external and internal
- Source load 0 ... 550 Ω, open-circuit voltage ≤ 18 V
- Sink Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,, series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage., The maximum value of the resistance is (V - 5)/0.0215 Ω.
- Fault signal downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
- Current range 0 ... 20 mA or 4 ... 20 mA
- Input resistance ≥ 1 MΩ (-100 ... 100 mV)
- Voltage selectable within the range -100 ... 100 mV
- Potentiometer 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
- Thermocouples type B, E, J, K, N, R, S, T (IEC 584-1: 1995), type L (DIN 43710: 1985), type TXK, TXKH, TXA (P8.585-2001)
- Measurement loop monitoring sensor breakage, sensor short-circuit
- Programming interface programming socket
- Measuring current approx. 200 µA with RTD
- RTD type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995), type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94), type Cu10, Cu50, Cu100 (P50353-92), type Ni100 (DIN 43760)
- Ripple within the supply tolerance
- Connection side field side
- Power consumption max. 1.53 W
- Types of measuring 2-, 3-wire connection
- Lead resistance max. 50 Ω per line
- Power dissipation ≤ 1.53 W
- Rated voltage 20 ... 30 V DC
- Safety Integrity Level (SIL) SIL 2
- Connection terminals 14+, 15- or power feed module/Power Rail
- Signal type Analog input
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents KFD2-UT2-EX2 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Pepperl + Fuchs
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Pepperl + Fuchs Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Pepperl + Fuchs Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Pepperl + Fuchs, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.