controller CPX-E-CEC-C1-PN Dimensions W x L x H: 75,9 mm x 124,3 mm x 82,5 mm, Grid dimension: 18,9 mm, CPU data: (* 512 MB RAM, * Dual Core 766 MHz), Diagnostics via LED: (* Force mode, * Network errors, * Network status engineering port 1, * Network sta
About the manufacturer: Festo is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.
Check out the 4252741 Festo price in the box on the right side or send a quick quote.
Product Details
- Fieldbus interface, connection type 2x socket
- Fieldbus interface 2, connection type Socket
- Fieldbus interface 2, connection pattern 00995789
- Ethernet interface, transmission rate 10 Mbit/s 100 Mbit/s
- Fieldbus interface 2, transmission rate 100 Mbit/s
- Width dimension 18.9 mm
- Power supply, type of connection Terminal strip
- Ethernet interface, connection technology RJ45
- Power supply, connection pattern 00995847
- Permissible voltage fluctuations for electronics/sensors ± 25 %
- Fieldbus interface, protocol PROFINET IO
- Ethernet interface, connection type 2x socket
- KC characters KC EMC
- Nominal operating voltage DC for electronics/sensors 24 V
- Dimensions W x L x H 75.9 mm x 124.3 mm x 82.5 mm
- Fieldbus interface 2, protocol EtherCAT Master
- Fieldbus interface 2, connection technology RJ45
- Power supply, function Electronics and sensors
- Ethernet interface, function Diagnostics Switch
- Fieldbus interface 2, function Bus connection, forwarding
- Power supply, connection technology Spring-loaded terminal
- Fieldbus interface 2, number of poles/wires 8
- Ethernet interface, number of poles/wires 8
- Power supply, conductor diameter 0.2 mm² ... 1.5 mm²
- Configuration support Operator unit CDSB GSDML file
- Function blocks and others Copying of CPX-E diagnostic trace
- Programming software CODESYS provided by Festo
- Certificate issuing authority UL E239998
- CE marking (see declaration of conformity) As per EU EMC directive
- Certification RCM compliance mark c UL us - Listed (OL)
- Fieldbus interface, transmission rate 100 Mbit/s
- Type of mounting With H-rail
- Vibration resistance Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6
- Storage medium Micro SD <= 32 GB USB memory stick <= 32 GB
- Note on ambient temperature -5 - 60 °C for vertical installation
- Fieldbus interface, function Bus connection, incoming/forwarding
- USB interface USB 2.0
- System parameter Diagnostic memory System start
- Ethernet interface, connection pattern 00995789
- Shock resistance Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27
- Power supply, number of pins/wires 4
- Fieldbus interface, max. address volume for inputs 512 byte
- Type code CPX-E
- Processing time Approx. 200 µs/1 k instruction
- Max. power supply 8 A
- Relative air humidity 95 % Non-condensing
- Max. address capacity outputs 64 byte
- Housing material PA
- Ethernet interface, protocol EasyIP TCP/IP
- Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 150 mA
- Fieldbus interface, connection pattern 00995789
- Fieldbus interface 2, galvanic isolation yes
- Fieldbus interface, connection technology RJ45
- Module parameters Channel alarm bundling Analog module process value representation
- Fieldbus interface, number of poles/wires 8
- Max. number of modules 10
- Additional functions CODESYS V3
- IP address setting DHCP Optional: via CDSB operating unit
- Power failure buffering 20 ms
- Corrosion resistance class (CRC) 0 - No corrosion stress
- Protection against direct and indirect contact PELV
- Product weight 288 g
- Fieldbus interface, type Ethernet
- Power supply, information on conductor diameter 0.2 - 2.5 mm² for flexible conductors without cable end sleeves
- Fieldbus interface 2, type Ethernet
- Diagnostics via LED Force mode Maintenance required
- Fieldbus interface, max. address volume for outputs 512 byte
- Buffer time real-time clock 3 Weeks
- Degree of protection IP20
- Max. address capacity inputs 64 byte
- Note on materials Contains paint-wetting impairment substances RoHS-compliant
- CPU data 512 MB RAM Dual core 766 MHz
- Control elements DIL switch for RUN/STOP Optional: CDSB operating unit
- Flag 120 kB remanent data CODESYS variable concept
- Program memory 12 MB user program
- Storage temperature -20 °C ... 70 °C
- Ambient temperature -5 °C ... 50 °C
- Fieldbus interface, galvanic isolation yes
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 4252741 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Festo
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Festo Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨