controller CPX-E-CEC-M1-PN Dimensions W x L x H: 75,9 mm x 124,3 mm x 82,5 mm, Grid dimension: 18,9 mm, CPU data: (* 512 MB RAM, * Dual Core 766 MHz), Diagnostics via LED: (* Force mode, * Network errors, * Network status engineering port 1, * Network sta
About the manufacturer: Festo is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.
Check out the 4252743 Festo price in the box on the right side or send a quick quote.
Product Details
- Housing material PA
- Vibration resistance Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6
- Fieldbus interface 2, connection type Socket
- Fieldbus interface, function Bus connection, incoming/forwarding
- Fieldbus interface 2, transmission rate 100 Mbit/s
- Ethernet interface, connection pattern 00995789
- Power supply, connection technology Spring-loaded terminal
- Fieldbus interface 2, number of poles/wires 8
- Power supply, conductor diameter 0.2 mm² ... 1.5 mm²
- Control elements DIL switch for RUN/STOP Optional: CDSB operating unit
- Function blocks and others Copying of CPX-E diagnostic trace
- Programming software CODESYS provided by Festo
- Ambient temperature -5 °C ... 50 °C
- Max. address capacity outputs 64 byte
- Type of mounting With H-rail
- Dimensions W x L x H 75.9 mm x 124.3 mm x 82.5 mm
- Fieldbus interface, connection type 2x socket
- Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 150 mA
- Fieldbus interface, connection pattern 00995789
- Power supply, function Electronics and sensors
- Power supply, information on conductor diameter 0.2 - 2.5 mm² for flexible conductors without cable end sleeves
- Ethernet interface, function Diagnostics Switch
- Shock resistance Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27
- Ethernet interface, connection type 2x socket
- Nominal operating voltage DC for electronics/sensors 24 V
- Max. number of modules 10
- Buffer time real-time clock 3 Weeks
- Additional functions CODESYS V3 with SoftMotion
- IP address setting DHCP Optional: via CDSB operating unit
- Program memory 12 MB user program
- Protection against direct and indirect contact PELV
- Certification RCM compliance mark c UL us - Listed (OL)
- Fieldbus interface, transmission rate 100 Mbit/s
- Power supply, type of connection Terminal strip
- Note on ambient temperature -5 - 60 °C for vertical installation
- Fieldbus interface 2, connection technology RJ45
- Power supply, connection pattern 00995847
- Fieldbus interface 2, function Bus connection, forwarding
- Fieldbus interface, protocol PROFINET IO
- KC characters KC EMC
- Fieldbus interface, max. address volume for inputs 512 byte
- Configuration support Operator unit CDSB GSDML file
- Processing time Approx. 200 µs/1 k instruction
- Power failure buffering 20 ms
- Certificate issuing authority UL E239998
- Storage temperature -20 °C ... 70 °C
- Note on materials Contains paint-wetting impairment substances RoHS-compliant
- Ethernet interface, protocol EasyIP TCP/IP
- Fieldbus interface 2, protocol EtherCAT Master
- Fieldbus interface 2, connection pattern 00995789
- USB interface USB 2.0
- System parameter Diagnostic memory System start
- Permissible voltage fluctuations for electronics/sensors ± 25 %
- Fieldbus interface 2, type Ethernet
- Diagnostics via LED Force mode Maintenance required
- Power supply, number of pins/wires 4
- Fieldbus interface, max. address volume for outputs 512 byte
- Width dimension 18.9 mm
- CPU data 512 MB RAM Dual core 766 MHz
- Flag 120 kB remanent data CODESYS variable concept
- CE marking (see declaration of conformity) As per EU EMC directive
- Relative air humidity 95 % Non-condensing
- Max. address capacity inputs 64 byte
- Fieldbus interface, galvanic isolation yes
- Storage medium Micro SD <= 32 GB USB memory stick <= 32 GB
- Ethernet interface, connection technology RJ45
- Ethernet interface, transmission rate 10 Mbit/s 100 Mbit/s
- Fieldbus interface 2, galvanic isolation yes
- Fieldbus interface, connection technology RJ45
- Module parameters Channel alarm bundling Analog module process value representation
- Ethernet interface, number of poles/wires 8
- Fieldbus interface, number of poles/wires 8
- Type code CPX-E
- Max. power supply 8 A
- Corrosion resistance class (CRC) 0 - No corrosion stress
- Degree of protection IP20
- Product weight 288 g
- Fieldbus interface, type Ethernet
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 4252743 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Festo
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Festo Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Festo Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Festo, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨