Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

X20CP3686X B&R Electronic Components

B&R X20CP3686X X20 PLC, Atom 1.3 GHz, 1 GB DDR4 RAM, 1 MB SRAM, 2 GB onboard flash drive, removable application memory: CompactFlash, 3 insert slots for X20 interface modules, 2 USB interfaces, 1 RS232 interface, 1 Ethernet interface (TSN) 10/100/1000BASE-T, 1 POWERLINK
B&R

Part#:X20CP3686X

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X20 PLC, Atom 1.3 GHz, 1 GB DDR4 RAM, 1 MB SRAM, 2 GB onboard flash drive, removable application memory: CompactFlash, 3 insert slots for X20 interface modules, 2 USB interfaces, 1 RS232 interface, 1 Ethernet interface (TSN) 10/100/1000BASE-T, 1 POWERLINK

Check out the X20CP3686X B&R price in the box on the right side or send a quick quote.

Product Details

  • Weight530 g
  • Temperature Operation Horizontal mounting orientation
    -25 to 60°C
  • Interface IF3 Transfer Auto-MDI/MDIX
    Yes
  • Temperature Operation Vertical mounting orientation
    -25 to 50°C
  • Interface IF3 Transfer Autonegotiation
    Yes
  • Interface IF3 Transfer Full-duplex
    POWERLINK mode: No / Ethernet mode: Yes
  • Interface IF2 Transfer Full-duplex
    Yes
  • Interface IF2 Transfer Auto-MDI/MDIX
    Yes
  • Interface IF2 Transfer Autonegotiation
    Yes
  • Interface IF3 Transfer Physical layer
    100BASE-TX
  • Interface IF3 Transfer Half-duplex
    Yes
  • Interface IF2 Transfer Half-duplex
    Yes
  • Application memory Writable data amount Guaranteed
    40 TB
  • Interface IF2 Transfer Physical layer
    10BASE-T/100BASE-TX/1000BASE-T
  • Processor L1 cache Program code
    32 kB
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Application memory Writable data amount Results for 5 years
    21.9 GB/day
  • Dimensions Width
    200 mm
  • Dimensions Depth
    85 mm
  • Dimensions Height
    99 mm
  • Processor L1 cache Data code
    24 kB
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Storage
    -40 to 70°C
  • Temperature Transport
    -40 to 70°C
  • Temperature Derating
    See section "Derating".
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Interface IF6 Fieldbus
    X2X Link / X2X+ master
  • Mounting orientation Horizontal
    Yes
  • Mounting orientation Vertical
    Yes
  • Interface IF5 Max. output current
    0.5 A
  • Interface IF4 Max. output current
    0.5 A
  • Interface IF5 Variant
    Type A
  • Interface IF5 Type
    USB 1.1/2.0
  • Interface IF4 Variant
    Type A
  • Interface IF4 Type
    USB 1.1/2.0
  • Interface IF3 Line length
    Max. 100 m between 2 stations (segment length)
  • Interface IF3 Transfer rate
    100 Mbit/s
  • Interface IF3 Type
    Type 4
  • Interface IF2 Transfer rate
    10/100/1000 Mbit/s
  • Interface IF3 Variant
    1x RJ45 shielded
  • Interface IF2 Variant
    1x RJ45 shielded
  • Interface IF2 Signal
    Ethernet
  • Interface IF3 Fieldbus
    POWERLINK (V2) managing or controlled node
  • Interface IF2 Line length
    Max. 100 m between 2 stations (segment length)
  • Interface IF1 Max. distance
    900 m
  • Interface IF1 Transfer rate
    Max. 115.2 kbit/s
  • Interface IF1 Signal
    RS232
  • Interface IF1 Variant
    Connection made using 12-pin terminal block X20TB12
  • Application memory Error-correcting code (ECC)
    Yes
  • Application memory Data retention
    10 years
  • Standard memory User RAM
    1 MB SRAM
  • Application memory Guaranteed erase/write cycles
    20,000
  • Application memory Type
    2 GB eMMC flash memory
  • Standard memory RAM
    1 GB LPDDR4 SDRAM
  • Data buffering Battery monitoring
    Yes
  • Data buffering Lithium battery
    During operation: 4 years; PLC switched off: Min. 2 years at 23°C ambient temperature
  • Processor Type
    Atom E3930
  • Processor Clock frequency
    1.3 GHz
  • Processor L2 cache
    1 MB
  • Electrical isolation I/O supply - I/O power supply
    No
  • Electrical isolation CPU/X2X Link supply - CPU/X2X Link power supply
    Yes
  • Diagnostics Overload
    Yes, using LED status indicator and software
  • Diagnostics RS232 data transfer
    Yes, using LED status indicator
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • Certifications UKCA
    Yes
  • Certifications CE
    Yes
  • Power consumption Internal I/O
    0.6 W
  • Support Visual Components support
    Yes
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Support Storage health data support
    Yes
  • Support ACOPOS support
    Yes
  • Support Controller redundancy
    Yes
  • Diagnostics Temperature
    Yes, using software register
  • Diagnostics Ethernet
    Yes, using LED status indicator
  • Diagnostics POWERLINK
    Yes, using LED status indicator
  • Diagnostics CompactFlash
    Yes, using LED status indicator
  • Diagnostics Battery
    Yes, using LED status indicator and software
  • Electrical isolation
    Ethernet (IF2), POWERLINK (IF3) and X2X (IF6) isolated from each other, from other interfaces and from PLC
  • Diagnostics CPU function
    Yes, using LED status indicator
  • Note
    Order application memory (CompactFlash) separately ; Backup battery included in delivery ; X20 end cover plate (right) included in delivery ; 12-pin X20 terminal block included in delivery ; Interface module slot covers included in delivery
  • Typical instruction cycle time
    0.0015 µs
  • Shortest task class cycle time
    100 µs
  • Degree of protection per EN 60529
    IP20
  • Remanent variables
    Max. 1 MB
  • Real-time clock
    Nonvolatile, resolution 1 s, -20 to 20 ppm accuracy at 25°C
  • Modular interface slots
    3
  • Integrated I/O processor
    Processes I/O data points in the background
  • Nominal output voltage
    24 VDC
  • CompactFlash slot
    1
  • Nominal output power
    7 W
  • Fuse
    Integrated, cannot be replaced
  • FPU
    Yes
  • Reverse polarity protection
    Yes
  • Permissible contact load
    10 A
  • Parallel connection
    Yes
  • Input current
    Max. 1.5 A
  • Input voltage
    24 VDC -15% / +20%
  • B&R ID code
    0xF9F9
  • Redundant operation
    Yes
  • Power consumption without interface module and USB
    7.5 W
  • Status indicators
    CPU function, Ethernet, POWERLINK, CompactFlash, battery
  • Power consumption for X2X Link power supply
    1.42 W
  • Cooling
    Fanless
  • System module
    Controller
  • Interfaces
    1x RS232, 1x Ethernet, 1x POWERLINK (V2), 2x USB, 1x X2X Link/X2X+

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo