ACOPOSmulti SafeMOTION SinCos inverter module, 88 A, AS, cold plate or pass-through mounting
Check out the 8BVI0880HCSA.008-1 B&R price in the box on the right side or send a quick quote.
Product Details
- Weight7.65 kg
- Dimensions Depth Pass-through mounting 209 mm
- Dimensions Depth Cold plate 212 mm
- Temperature Operation Nominal 5 to 40°C
- Temperature Operation Maximum 55°C
- Encoder power supply Protective measures Overload-proof Yes
- Sine/Cosine inputs Differential voltage In motion 0.5 to 1.35 V
- Sine/Cosine inputs Differential voltage At standstill 0.8 to 1.35 V
- Encoder power supply Protective measures Short-circuit proof Yes
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Pass-through mounting 0.54 A/K (starting at -106°C)
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Pass-through mounting 0.88 A/K (starting at -12°C)
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Cold plate mounting 0.75 A/K (starting at -37°C)
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Pass-through mounting 1.82 A/K (starting at 40°C)
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Cold plate mounting 1.9 A/K (starting at 58°C)
- Relative humidity Transport Max. 95% at 40°C
- Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Cold plate mounting 1.36 A/K (starting at 27°C)
- Dimensions Height 317 mm
- Dimensions Width 213.5 mm
- Relative humidity Storage 5 to 95%
- Temperature Transport -25 to 70°C
- Relative humidity Operation 5 to 85%
- Installation elevation above sea level Maximum 4000 m
- Installation elevation above sea level Nominal 0 to 500 m
- Permissible mounting orientations Horizontal, face up Yes
- Temperature Storage -25 to 55°C
- Permissible mounting orientations Standing horizontally No
- Switching delay Rising edge 52 µs ±0.5 µs (digitally filtered)
- Permissible mounting orientations Hanging vertically Yes
- Switching delay Falling edge 53 µs ±0.5 µs (digitally filtered)
- Electrical isolation Input - Input Yes
- Switching threshold Low <5 V
- Switching threshold High >15 V
- Input voltage Nominal 24 VDC
- Input voltage Maximum 30 VDC
- Sine/Cosine inputs Signal frequency (-3 dB) DC up to 200 kHz
- Position Noise ---
- Position Resolution @ 1 VSS Number of encoder lines * 5700
- Reference input Terminating resistor 120 Ω
- Electrical isolation Input - Inverter module Yes
- Sine/Cosine inputs Max. input frequency 200 kHz
- Position Accuracy ---
- Sine/Cosine inputs ADC resolution 12-bit
- Reference input Signal transmission Differential signal, symmetrical
- Sine/Cosine inputs Differential voltage deviation per signal period ±10%
- Reference input Common-mode voltage Max. -5 V to +9 V
- Sine/Cosine inputs Common-mode voltage Max. ±7 V
- Sine/Cosine inputs Signal frequency (-5 dB) <300 kHz
- Reference input Differential voltage for low ≤-0.2 V
- Sine/Cosine inputs Terminating resistor 120 Ω
- Reference input Differential voltage for high ≥0.2 V
- Sine/Cosine inputs Signal transmission Differential signals, symmetrical
- Encoder power supply Sense lines 2, compensation of max. 2 x 0.7 V
- Synchronous serial interface Data transfer rate 781.25 kbit/s
- Synchronous serial interface Signal transmission RS485
- Encoder power supply Load capacity 300 mA
- Protective measures Open-circuit monitoring Yes
- Protective measures Overload and short-circuit protection Yes
- Electrical isolation Encoder - ACOPOSmulti No
- Max. motor line length depending on switching frequency Switching frequency 10 kHz 25 m
- Encoder power supply Output voltage 5 V ±5%
- Protective measures Undervoltage monitoring Yes
- Connection cross section range Flexible and fine-stranded wires ---
- Max. motor line length depending on switching frequency Switching frequency 20 kHz 25 m
- Max. motor line length depending on switching frequency Switching frequency 5 kHz 25 m
- Protective measures Short-circuit and ground fault protection Yes
- Variant U, V, W, PE M8 threaded bolts
- Variant Shield connection Yes
- Protective measures Overload protection Yes
- Output voltage DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
- Reduction of continuous current depending on installation elevation Starting at 500 m above sea level 8.8 Aeff per 1000 m
- Voltage Nominal 750 VDC
- Power dissipation depending on switching frequency Switching frequency 10 kHz In preparation
- Power dissipation depending on switching frequency Switching frequency 20 kHz In preparation
- Power dissipation depending on switching frequency Switching frequency 5 kHz In preparation
- Output voltage DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315)
- Certifications Functional safety Yes (openSAFETY)
- Certifications UL cULus E225616; Power conversion equipment
- Input capacitance 32.9 µF
- Certifications CE Yes
- Module width 4
- Max. power consumption 25 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake
- Overvoltage category per EN 61800-5-1 III
- Degree of protection per EN 60529 IP20
- Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
- DC bus capacitance 1980 µF
- Discharge capacitance 0.44 µF
- Input current at nominal voltage Approx. 10 mA
- Modulation compared to ground potential Max. ±38 V
- Circuit Sink
- Max. encoder cable length 50 m
- Max. power consumption per encoder interface PSMC[W] = 25 V * (0.376 A + 0.35 * IEncoder[A])
- Encoder monitoring Yes
- Input voltage 25 VDC ±1.6%
- Status indicators UP/DN LEDs
- Response threshold for undervoltage monitoring 24 VDC -2% / -4%
- Connections 15-pin female DSUB connector
- Response threshold for open-circuit monitoring Approx. 0.5 A
- Max. switching frequency 0.5 Hz
- Continuous power consumption 65 kW
- Variant ACOPOSmulti backplane
- Slots for plug-in modules 2
- Type SinCos
- Max. internal resistance 0.15 Ω
- B&R ID code 0x2C28
- Cooling and mounting type Cold plate or pass-through mounting
- Extinction potential Approx. 30 V
- Max. extinction energy per switching operation 3 Ws
- Continuous current 4.2 A
- Output voltage 24 VDC +5.8% / -0.5%
- Terminal cable cross section dimension of shield connection 12 to 50 mm
- Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
- Max. output frequency 598 Hz
- Possible switching frequencies 5 / 10 / 20 kHz
- Nominal switching frequency 5 kHz
- Fuse protection 250 mA (slow-blow) electronic, automatic reset
- Peak current 176 Aeff
- Continuous current per motor connection 88 Aeff
- Continuous power per motor connection 64 kW
- Quantity 2
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents 8BVI0880HCSA.008-1 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of B&R
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
B&R Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨