8BVI0880HCSA.008-1 B&R Electronic Components

B&R 8BVI0880HCSA.008-1 ACOPOSmulti SafeMOTION SinCos inverter module, 88 A, AS, cold plate or pass-through mounting
B&R

Part#:8BVI0880HCSA.008-1

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

ACOPOSmulti SafeMOTION SinCos inverter module, 88 A, AS, cold plate or pass-through mounting

Check out the 8BVI0880HCSA.008-1 B&R price in the box on the right side or send a quick quote.

Product Details

  • Weight7.65 kg
  • Dimensions Depth Pass-through mounting
    209 mm
  • Dimensions Depth Cold plate
    212 mm
  • Temperature Operation Nominal
    5 to 40°C
  • Temperature Operation Maximum
    55°C
  • Encoder power supply Protective measures Overload-proof
    Yes
  • Sine/Cosine inputs Differential voltage In motion
    0.5 to 1.35 V
  • Sine/Cosine inputs Differential voltage At standstill
    0.8 to 1.35 V
  • Encoder power supply Protective measures Short-circuit proof
    Yes
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Pass-through mounting
    0.54 A/K (starting at -106°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Pass-through mounting
    0.88 A/K (starting at -12°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Cold plate mounting
    0.75 A/K (starting at -37°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Pass-through mounting
    1.82 A/K (starting at 40°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Cold plate mounting
    1.9 A/K (starting at 58°C)
  • Relative humidity Transport
    Max. 95% at 40°C
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Cold plate mounting
    1.36 A/K (starting at 27°C)
  • Dimensions Height
    317 mm
  • Dimensions Width
    213.5 mm
  • Relative humidity Storage
    5 to 95%
  • Temperature Transport
    -25 to 70°C
  • Relative humidity Operation
    5 to 85%
  • Installation elevation above sea level Maximum
    4000 m
  • Installation elevation above sea level Nominal
    0 to 500 m
  • Permissible mounting orientations Horizontal, face up
    Yes
  • Temperature Storage
    -25 to 55°C
  • Permissible mounting orientations Standing horizontally
    No
  • Switching delay Rising edge
    52 µs ±0.5 µs (digitally filtered)
  • Permissible mounting orientations Hanging vertically
    Yes
  • Switching delay Falling edge
    53 µs ±0.5 µs (digitally filtered)
  • Electrical isolation Input - Input
    Yes
  • Switching threshold Low
    <5 V
  • Switching threshold High
    >15 V
  • Input voltage Nominal
    24 VDC
  • Input voltage Maximum
    30 VDC
  • Sine/Cosine inputs Signal frequency (-3 dB)
    DC up to 200 kHz
  • Position Noise
    ---
  • Position Resolution @ 1 VSS
    Number of encoder lines * 5700
  • Reference input Terminating resistor
    120 Ω
  • Electrical isolation Input - Inverter module
    Yes
  • Sine/Cosine inputs Max. input frequency
    200 kHz
  • Position Accuracy
    ---
  • Sine/Cosine inputs ADC resolution
    12-bit
  • Reference input Signal transmission
    Differential signal, symmetrical
  • Sine/Cosine inputs Differential voltage deviation per signal period
    ±10%
  • Reference input Common-mode voltage
    Max. -5 V to +9 V
  • Sine/Cosine inputs Common-mode voltage
    Max. ±7 V
  • Sine/Cosine inputs Signal frequency (-5 dB)
    <300 kHz
  • Reference input Differential voltage for low
    ≤-0.2 V
  • Sine/Cosine inputs Terminating resistor
    120 Ω
  • Reference input Differential voltage for high
    ≥0.2 V
  • Sine/Cosine inputs Signal transmission
    Differential signals, symmetrical
  • Encoder power supply Sense lines
    2, compensation of max. 2 x 0.7 V
  • Synchronous serial interface Data transfer rate
    781.25 kbit/s
  • Synchronous serial interface Signal transmission
    RS485
  • Encoder power supply Load capacity
    300 mA
  • Protective measures Open-circuit monitoring
    Yes
  • Protective measures Overload and short-circuit protection
    Yes
  • Electrical isolation Encoder - ACOPOSmulti
    No
  • Max. motor line length depending on switching frequency Switching frequency 10 kHz
    25 m
  • Encoder power supply Output voltage
    5 V ±5%
  • Protective measures Undervoltage monitoring
    Yes
  • Connection cross section range Flexible and fine-stranded wires
    ---
  • Max. motor line length depending on switching frequency Switching frequency 20 kHz
    25 m
  • Max. motor line length depending on switching frequency Switching frequency 5 kHz
    25 m
  • Protective measures Short-circuit and ground fault protection
    Yes
  • Variant U, V, W, PE
    M8 threaded bolts
  • Variant Shield connection
    Yes
  • Protective measures Overload protection
    Yes
  • Output voltage DC bus voltage (UDC): 315 to 800 VDC
    24 VDC ±6%
  • Reduction of continuous current depending on installation elevation Starting at 500 m above sea level
    8.8 Aeff per 1000 m
  • Voltage Nominal
    750 VDC
  • Power dissipation depending on switching frequency Switching frequency 10 kHz
    In preparation
  • Power dissipation depending on switching frequency Switching frequency 20 kHz
    In preparation
  • Power dissipation depending on switching frequency Switching frequency 5 kHz
    In preparation
  • Output voltage DC bus voltage (UDC): 260 to 315 VDC
    25 VDC * (UDC/315)
  • Certifications Functional safety
    Yes (openSAFETY)
  • Certifications UL
    cULus E225616; Power conversion equipment
  • Input capacitance
    32.9 µF
  • Certifications CE
    Yes
  • Module width
    4
  • Max. power consumption
    25 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake
  • Overvoltage category per EN 61800-5-1
    III
  • Degree of protection per EN 60529
    IP20
  • Pollution degree per EN 61800-5-1
    2 (non-conductive pollution)
  • DC bus capacitance
    1980 µF
  • Discharge capacitance
    0.44 µF
  • Input current at nominal voltage
    Approx. 10 mA
  • Modulation compared to ground potential
    Max. ±38 V
  • Circuit
    Sink
  • Max. encoder cable length
    50 m
  • Max. power consumption per encoder interface
    PSMC[W] = 25 V * (0.376 A + 0.35 * IEncoder[A])
  • Encoder monitoring
    Yes
  • Input voltage
    25 VDC ±1.6%
  • Status indicators
    UP/DN LEDs
  • Response threshold for undervoltage monitoring
    24 VDC -2% / -4%
  • Connections
    15-pin female DSUB connector
  • Response threshold for open-circuit monitoring
    Approx. 0.5 A
  • Max. switching frequency
    0.5 Hz
  • Continuous power consumption
    65 kW
  • Variant
    ACOPOSmulti backplane
  • Slots for plug-in modules
    2
  • Type
    SinCos
  • Max. internal resistance
    0.15 Ω
  • B&R ID code
    0x2C28
  • Cooling and mounting type
    Cold plate or pass-through mounting
  • Extinction potential
    Approx. 30 V
  • Max. extinction energy per switching operation
    3 Ws
  • Continuous current
    4.2 A
  • Output voltage
    24 VDC +5.8% / -0.5%
  • Terminal cable cross section dimension of shield connection
    12 to 50 mm
  • Insulation stress of the connected motor per IEC TS 60034-25:2004
    Limit value curve A
  • Max. output frequency
    598 Hz
  • Possible switching frequencies
    5 / 10 / 20 kHz
  • Nominal switching frequency
    5 kHz
  • Fuse protection
    250 mA (slow-blow) electronic, automatic reset
  • Peak current
    176 Aeff
  • Continuous current per motor connection
    88 Aeff
  • Continuous power per motor connection
    64 kW
  • Quantity
    2

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo