  • Weight4.3 kg
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Pass-through mounting
    1.26 A/K (starting at 40°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Pass-through mounting
    0.37 A/K (starting at -36°C)
  • Dimensions Height
    317 mm
  • Relative humidity Storage
    5 to 95%
  • Relative humidity Transport
    Max. 95% at 40°C
  • Temperature Storage
    -25 to 55°C
  • Relative humidity Operation
    5 to 85%
  • Permissible mounting orientations Hanging vertically
    Yes
  • Synchronous serial interface Signal transmission
    RS485
  • Electrical isolation Input - Inverter module
    Yes
  • Temperature Transport
    -25 to 70°C
  • Permissible mounting orientations Standing horizontally
    No
  • Switching threshold Low
    <5 V
  • Input voltage Maximum
    30 VDC
  • Switching delay Falling edge
    53 µs ±0.5 µs (digitally filtered)
  • Switching delay Rising edge
    52 µs ±0.5 µs (digitally filtered)
  • Switching threshold High
    >15 V
  • Input voltage Nominal
    24 VDC
  • Encoder power supply Output voltage
    Typ. 12.5 V
  • Electrical isolation Encoder - ACOPOSmulti
    No
  • Protective measures Open-circuit monitoring
    Yes
  • Protective measures Overload and short-circuit protection
    Yes
  • Max. motor line length depending on switching frequency Switching frequency 20 kHz
    25 m
  • Protective measures Short-circuit and ground fault protection
    Yes
  • Max. motor line length depending on switching frequency Switching frequency 10 kHz
    25 m
  • Variant U, V, W, PE
    Connector
  • Variant Shield connection
    Yes
  • Certifications UL
    cULus E225616; Power conversion equipment
  • Certifications KC
    Yes
  • Protective measures Overload protection
    Yes
  • Voltage Nominal
    750 VDC
  • Reduction of continuous current depending on installation elevation Starting at 500 m above sea level
    4.4 Aeff per 1000 m
  • Output voltage DC bus voltage (UDC): 315 to 800 VDC
    24 VDC ±6%
  • Power dissipation depending on switching frequency Switching frequency 5 kHz
    [0.07 * IM² + 7.3 * IM + 40] W
  • Certifications CE
    Yes
  • Certifications EAC
    Yes
  • Degree of protection per EN 60529
    IP20
  • Module width
    2
  • Pollution degree per EN 61800-5-1
    2 (non-conductive pollution)
  • Input current at nominal voltage
    Approx. 10 mA
  • Circuit
    Sink
  • Discharge capacitance
    0.22 µF
  • Max. encoder cable length
    100 m ; Depends on the cross section of the power supply wires in the encoder cable
  • Status indicators
    UP/DN LEDs
  • Max. power consumption per encoder interface
    PSMC[W] = 19 V * IEncoder[A]
  • Response threshold for open-circuit monitoring
    Approx. 0.5 A
  • Response threshold for undervoltage monitoring
    24 VDC -2% / -4%
  • Terminal cable cross section dimension of shield connection
    23 to 35 mm
  • Max. internal resistance
    0.15 Ω
  • Continuous current
    4.2 A
  • Extinction potential
    Approx. 30 V
  • Max. switching frequency
    0.5 Hz
  • Insulation stress of the connected motor per IEC TS 60034-25:2004
    Limit value curve A
  • Nominal switching frequency
    5 kHz
  • Continuous power per motor connection
    32 kW
  • Possible switching frequencies
    5 / 10 / 20 kHz
  • Continuous current per motor connection
    44 Aeff
  • Input capacitance
    32.9 µF
  • Continuous power consumption
    32.5 kW
  • Fuse protection
    250 mA (slow-blow) electronic, automatic reset
  • Variant
    ACOPOSmulti backplane
  • B&R ID code
    0xAA1F
  • Max. power consumption
    31 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake
  • Input voltage
    25 VDC ±1.6%
  • Slots for plug-in modules
    2
  • Temperature Operation Nominal
    5 to 40°C
  • Encoder power supply Protective measures Overload-proof
    Yes
  • Dimensions Depth Cold plate
    212 mm
  • Encoder power supply Protective measures Short-circuit proof
    Yes
  • Terminal connection cross section Approbation data CSA
    20 to 6
  • Terminal connection cross section Approbation data UL/C-UL-US
    20 to 6
  • Terminal connection cross section Flexible and fine-stranded wires With wire end sleeves
    0.5 to 16 mm²
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Pass-through mounting
    0.24 A/K (starting at -137°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 20 kHz Cold plate mounting
    0.32 A/K (starting at -82°C)
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 10 kHz Cold plate mounting
    0.62 A/K (starting at 6°C)
  • Dimensions Width
    106.5 mm
  • Reduction of continuous current depending on switching frequency and mounting type Switching frequency 5 kHz Cold plate mounting
    0.8 A/K (starting at 45°C)
  • Installation elevation above sea level Maximum
    4000 m
  • Installation elevation above sea level Nominal
    0 to 500 m
  • Permissible mounting orientations Horizontal, face up
    Yes
  • Electrical isolation Input - Input
    Yes
  • Synchronous serial interface Data transfer rate
    6.25 Mbit/s
  • Encoder power supply Load capacity
    350 mA
  • Protective measures Undervoltage monitoring
    Yes
  • Max. motor line length depending on switching frequency Switching frequency 5 kHz
    25 m
  • Output voltage DC bus voltage (UDC): 260 to 315 VDC
    25 VDC * (UDC/315)
  • Power dissipation depending on switching frequency Switching frequency 10 kHz
    [0.2 * IM² + 11.1 * IM + 130] W
  • Power dissipation depending on switching frequency Switching frequency 20 kHz
    [1.85 * IM² + 3.8 * IM + 300] W
  • Certifications Functional safety
    Yes (openSAFETY)
  • Temperature Operation Maximum
    55°C
  • Dimensions Depth Pass-through mounting
    209 mm
  • Cooling and mounting type
    Cold plate or pass-through mounting
  • Overvoltage category per EN 61800-5-1
    III
  • DC bus capacitance
    990 µF
  • Modulation compared to ground potential
    Max. ±38 V
  • Encoder monitoring
    Yes
  • Type
    EnDat 2.2
  • Connections
    9-pin female DSUB connector
  • Max. extinction energy per switching operation
    3 Ws
  • Output voltage
    24 VDC +5.8% / -0.5%
  • Max. output frequency
    598 Hz
  • Peak current
    88 Aeff
  • Quantity
    2

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo