Filters
Manufacturer
Voltage Relays
part#
description
manufacturer
PILZ-890170
Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure.
Pilz
Quick Quote
PILZ-760100
Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement.
Pilz
Quick Quote
PILZ-890150
Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.
Pilz
Quick Quote
PILZ-890120
Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.
Pilz
Quick Quote
PILZ-890050
Pilz PILZ-890050 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, adjustable switching thresholds for underload and overload conditions, and customizable monitoring reaction and start-up suppression times. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering a wide range of nominal voltages. The S1WP sub-range unit has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency range of 0-1kHz. Constructed with a PPO housing, it is designed for both single-phase and 3-phase input networks, with a rated voltage measuring capacity of 0-415Vac/dc. The net width is 22.5 mm, and it consumes 5 VA of power. It has a net depth of 121 mm and can be stored in temperatures ranging from -40 to +85°C. The unit includes one auxiliary output (SPDT-NO/NC contacts) for resistive loads and two analog inputs for current and voltage measurement, alongside one analog output for voltage and current signaling. It is equipped with underpower and overpower protection functions.
Pilz
Quick Quote
PILZ-839770
Pilz PILZ-839770 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and supports a supply voltage range of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), belonging to the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is housed in a PPO material casing. The PILZ-839770 has a net width of 22.5 mm, a depth of 121 mm, and consumes 2 W of power. It features an operating mode that allows for automatic reset or manual reset in a normally energized mode. The unit is designed to withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and offers protection functions against overheating with its thermistor. Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10 million operations at no load.
Pilz
Quick Quote
PILZ-838000
Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load.
Pilz
Quick Quote
PILZ-837370
Pilz PILZ-837370 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range, and the device dimensions are 22.5mm in width. It offers an IP40 degree of protection and operates across a frequency range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 415/460Vac for measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W. The operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs.
Pilz
Quick Quote
PILZ-837360
Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Pilz
Quick Quote
PILZ-837305
Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Pilz
Quick Quote
PILZ-827260
Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3).
Pilz
Quick Quote
PILZ-827240
Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s.
Pilz
Quick Quote
PILZ-890165
Pilz PILZ-890165 is a protection unit designed for phase sequence monitoring relay applications. It features DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and utilizes fixed screw terminal connections for secure installation. It is designed to work with a supply voltage range of 400Vac-500Vac, specifically accommodating 415Vac, 440Vac, and 480Vac nominal values, within the S1PN sub-range. The dimensions include a width of 22.5mm and a depth of 121 mm, offering a compact form factor with an IP40 degree of protection. The housing is made from PPO material, ensuring durability. This model is suitable for 3-phase (3AC) input networks with a rated voltage of 400-500Vac. It has a power consumption of 8 VA and operates in a normally energized mode. For connectivity, it features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 1 x analog input for L1-L3 voltage measurement. The protection functions include phase sequence and phase failure, ensuring the safety and proper operation of connected systems.
Pilz
Quick Quote
PILZ-890100
Pilz PILZ-890100 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, adjustable switching for underload and overload thresholds, and customizable monitoring reaction and start-up suppression times. This unit is suitable for DIN rail mounting and has a net height of 87 mm. It supports a rated current of 18A for measuring and safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). The connection is established via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and operates on a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz, and it is housed in a PPO material. It accommodates both single-phase (1AC) and three-phase (3AC) input types, with a rated voltage for AC measuring up to 240Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It is designed to operate within an ambient air temperature range for storage of -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, and it also features 1 x analog output for voltage (U) and current (I) monitoring.
Pilz
Quick Quote
PILZ-890070
Pilz PILZ-890070 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching thresholds for underload and overload conditions, along with customizable monitoring reaction times and start-up suppression times. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is designed to measure from 0 percent, with a rated current of 9A for measuring current. The safety output contacts ratings are specified as 0.1A-5A for both 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and 0.1A-1.5A for 24Vdc (DC-13) as well as 0.1A-1.8A for 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage ranges from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, with nominal values including 110Vac/120Vac/220Vac/230Vac for AC and 110Vdc/120Vdc/220Vdc/250Vdc for DC. The S1WP sub-range model has dimensions of W22.5mm and offers IP40 degree of protection. It operates within a frequency range of 0-1kHz for measuring, encased in a PPO housing. This unit is compatible with both single-phase (1AC) and 3-phase (3AC) input types of network, with a rated voltage of 0-415Vac/dc for measuring voltage. The net width is 22.5 mm, and it consumes 5 VA of power, with a net depth of 121 mm. It can be stored in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Its protection functions include underpower and overpower, with 1 x analog output for voltage-U and current-I measurements.
Pilz
Quick Quote
PILZ-890060
Pilz PILZ-890060 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is capable of handling a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for various nominal voltages, as well as a DC supply voltage range of 93.5-287.5Vdc. The unit operates within a frequency range of 0-1kHz for measuring, is housed in PPO material, and can be used with both single-phase and 3-phase input networks. The rated voltage for measuring is up to 550Vac/dc, with a net width of 22.5 mm and a depth of 121 mm. It has a power consumption of 5 VA, an IP40 degree of protection, and is designed for storage in temperatures ranging from -40 to +85°C. The unit includes 1 x auxiliary output (SPDT-NO/NC contacts) for resistive loads, 1 x analog input for current measurement, 1 x analog input for voltage measurement, and 1 x analog output for voltage and current signaling, with underpower and overpower protection functions.
Pilz
Quick Quote
PILZ-890000
Pilz PILZ-890000 is an insulation monitor designed for DIN rail mounting, featuring insulation monitoring relay, insulation monitoring, earth fault monitoring, and a test mode. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The device supports rated current safety output contacts ratings from 0.1A to 5A for both 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), along with 1.5A for 24Vdc (DC-13) and 2A for 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage ranges from 24Vac to 240Vac (with nominal voltages of 110Vac, 220Vac, 230Vac) and from 24Vdc to 240Vdc (with nominal voltages of 110Vdc, 120Vdc, 220Vdc). It belongs to the S1EN sub-range, measures 22.5mm in width, and offers a degree of protection of IP40. The housing is made of PPO material, and it can handle rated voltages up to 400Vac. The net width is 22.5 mm, and it consumes 1 W of power, with a net depth of 121 mm. Operating modes include automatic reset/manual reset and normally energized mode. It can be stored in temperatures ranging from -40 to +85°C. The device includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), protection functions against overcurrent, and digital inputs for main voltage (42-240Vac and 24Vdc) and a reset input.
Pilz
Quick Quote
PILZ-840765
Pilz PILZ-840765 is a protection unit designed for thermistor monitoring relay thermistor monitoring with a DIN rail mounting mode. It operates within an ambient air temperature range of -10 to +55°C and features a net height of 87 mm. This unit is equipped with an automatic reset design and fixed screw terminal connections. It supports a supply voltage of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), falling under the S1MS sub-range. The dimensions include a width of 22.5mm and a degree of protection rated at IP40, with a PPO housing material. The net width is 22.5 mm, and it has a power consumption of 2 W, with a net depth of 121 mm. Its operating mode is an automatic reset in a normally energized mode. The digital outputs consist of 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) (12-14-11; 22-24-21), and it also features 2 x analog inputs (T1-T2 measuring circuits). The protection functions include overheating protection (Thermistor).
Pilz
Quick Quote
PILZ-840420
Pilz PILZ-840420 is a protection unit designed for thermistor monitoring relay thermistor monitoring with a manual reset design. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. The unit has a net height of 87 mm and is equipped with fixed screw terminal connections. It supports a supply voltage of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), falling under the S1MO sub-range. The dimensions include a width of 22.5 mm and a depth of 121 mm, with a degree of protection rated at IP40. Constructed with a PPO housing, it has a net width of 22.5 mm and consumes 2 W of power. The operating mode is manual reset in a normally energized mode. It can be stored in temperatures ranging from -40 to +85 °C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and 2 x reset circuit inputs (X2-X1) for digital inputs. Its protection functions include overheating protection through thermistor monitoring.
Pilz
Quick Quote
PILZ-840630
Pilz PILZ-840630 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit has a net height of 87 mm and incorporates a manual reset design with fixed screw terminal connections. It requires a supply voltage of 204-264Vac (240Vac nominal) and falls under the S1MO sub-range. The dimensions include a width of 22.5mm and a depth of 121 mm, offering a degree of protection of IP40. The housing is made of PPO material, ensuring durability. With a power consumption of 3.5 VA, this unit operates in a normally energized mode with manual reset functionality. It can withstand an ambient air temperature for storage between -40 and +85 °C. The PILZ-840630 features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and is equipped with 2 x reset circuit inputs (X2-X1) for digital inputs. Its protection functions are specifically designed for overheating protection, utilizing thermistors to safeguard against temperature-related issues.
Pilz
Quick Quote
Items per page: