M702-11403770E10101AB100
NIDEC M702-11403770E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor, dual Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports various communication protocols including Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT. It operates with a rated current of 437A under normal duty and 377A under heavy-duty conditions, and it is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The ambient air temperature for operation ranges from -20°C to +40°C, and it has a degree of protection rated at IP20 NEMA 1 UL open. The M702-11403770E10101AB100 is suitable for a 3-phase input network with a frequency of 45-66 Hz (supply input) and can output frequencies from 0-599 Hz. It includes 2 x digital inputs (0-24Vdc), with terminal 8 configurable as a motor protection thermistor, and 2 x digital outputs (100mA / 0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type). The rated active power is 225kW under normal duty and 185kW under heavy-duty, equivalent to 350HP and 300HP respectively.
Nidec
Quick Quote
M702-10601780E10101AN100
NIDEC M702-10601780E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with dual Safe Torque Off (STO) and requires an external choke and air cooling for operation. It features a frame size of 10E with dimensions of H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports various communication protocols including Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT. It operates with a rated current of 197A under normal duty and 178A under heavy-duty conditions, and it is designed for a supply voltage range of 500Vac-690Vac (600Vac). The ambient air temperature for operation ranges from -20°C to +40°C. It offers a degree of protection of IP20, NEMA 1, and UL open. The device is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor), 2 x digital outputs (100mA / 0-24Vdc; source), and 1 x digital output (2A / 240Vac; source; relay contact type). The rated active power is 185kW under normal duty and 160kW under heavy-duty, corresponding to 250HP and 200HP, respectively.
Nidec
Quick Quote
M702-10601500E10101AN100
NIDEC M702-10601500E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M702 series designed for variable speed control with a dual Safe Torque Off (STO) feature, requiring an external choke and air cooling. It has dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports multiple communication protocols including Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT. It operates with a rated current of 172A under normal duty and 150A under heavy-duty conditions, and can handle a supply voltage range of 500Vac-690Vac (600Vac). The ambient air temperature for operation is specified from -20°C to +40°C. It offers an IP20, NEMA 1, and UL open degree of protection. The device is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x digital inputs (0-24Vdc), with terminal 8 configurable as a motor protection thermistor, and 3 x digital outputs (2 x 100mA / 0-24Vdc; source and 1 x 2A / 240Vac; source; relay contact type). The rated active power is 160kW under normal duty and 132kW under heavy-duty, corresponding to 200HP and 175HP respectively.
Nidec
Quick Quote
SP5402
NIDEC SP5402 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with a single Safe Torque Off (STO) and air cooling. It features a frame size of 5, measuring H33.75" x W12.2" x D11.73" (H857mm x W310mm x D298mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The rated current is 168A under normal duty and 156A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and offers a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol and operates on a network frequency of 48-65 Hz (supply input) and 0-550 Hz (output). The SP5402 includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). Analog interface options include 1 x analog input (-9.8Vdc...9.8Vdc; differential) with 16-bit conversion resolution and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with 10-bit conversion resolution, along with 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) also with 10-bit conversion resolution. The rated active power is 90kW for normal duty and 75kW for heavy-duty, with a rated power of 125HP for both duty types.
Nidec
Quick Quote
SP3505-HF
NIDEC SP3505-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max. in an open-loop configuration with a single Safe Torque Off (STO) and air cooling. It features a frame size 3 with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 500Vac-575Vac. The rated current is 16A under normal duty and 12A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and offers a degree of protection rated at IP20 NEMA 1. Communication is facilitated via Modbus RTU RS-485, supporting a network frequency of 48-65 Hz on the supply input and 0-3000 Hz on the output. It includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and analog inputs/outputs with varying specifications. The rated active power is 11kW for normal duty and 7.5kW for heavy-duty, corresponding to 15HP and 10HP, respectively.
Nidec
Quick Quote
SP3501-HF
NIDEC SP3501-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max. in an open-loop configuration with a single Safe Torque Off (STO) and air cooling. It features a frame size 3 with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 500Vac-575Vac. The rated current is 5.4A under normal duty and 4.1A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol and operates on a network frequency of 48-65 Hz (supply input) with an output frequency range of 0-3000 Hz. The SP3501-HF includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). For analog interfacing, it offers 1 x analog input (-9.8Vdc...9.8Vdc; differential) and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution, alongside 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) also with a 10-bit conversion resolution. The rated active power is 3kW for normal duty and 2.2kW for heavy-duty, corresponding to a rated power of 3HP and 2HP respectively.
Nidec
Quick Quote
SP3403
NIDEC SP3403 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with a single Safe Torque Off (STO) and air cooling. It features a frame size 3 with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The rated current is 56A under normal duty and 46A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol and operates with a network frequency of 48-65 Hz (supply input) and 0-550 Hz (output). The SP3403 includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). It also features 1 x analog input (-9.8Vdc...9.8Vdc; differential) with a 16-bit conversion resolution, 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution, and 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) with a 10-bit conversion resolution. The rated active power is 30kW for normal duty and 22kW for heavy-duty, corresponding to 40HP and 30HP, respectively.
Nidec
Quick Quote
SP3402-HF
NIDEC SP3402-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in an open-loop configuration with a single Safe Torque Off (STO) and air cooling. It features a frame size 3 with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The rated current is 43A under normal duty and 40A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol and operates with a network frequency of 48-65 Hz on the supply input and can output 0-3000 Hz. The SP3402-HF includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). For analog interfacing, it offers 1 x analog input (-9.8Vdc...9.8Vdc; differential) and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 16-bit and 10-bit conversion resolution respectively, along with 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) with a 10-bit conversion resolution. The rated active power is 22kW for normal duty and 18.5kW for heavy-duty, with a rated power of 30HP for both operating modes.
Nidec
Quick Quote
SP3401-HF
NIDEC SP3401-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in open-loop configurations, featuring a single Safe Torque Off (STO) and air cooling. It has dimensions of frame size 3, measuring H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) with a rated current of 35A under normal duty and 32A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and offers a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol and operates on a network frequency of 48-65 Hz (supply input) with an output frequency range of 0-3000 Hz. The SP3401-HF includes 3 digital outputs (0-24Vdc; source), 1 digital output (2A / 240Vac; source; relay contact type), 3 digital inputs (0-24Vdc), and 3 additional digital inputs (0-24Vdc). It also features 1 analog input (-9.8Vdc...9.8Vdc; differential) and 2 analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 16-bit and 10-bit conversion resolution respectively, along with 2 analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) with a 10-bit conversion resolution. The rated active power is 18.5kW under normal duty and 15kW under heavy-duty, with a rated power of 25HP for both duty conditions.
Nidec
Quick Quote
SP3502-HF
NIDEC SP3502-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in open-loop configurations, featuring a single Safe Torque Off (STO) and air cooling. It has a frame size 3 with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 500Vac-575Vac. The rated current is 6.1A under normal duty and 5.4A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on supply input and an output frequency range of 0-3000 Hz. The SP3502-HF includes 3 digital outputs (0-24Vdc; source), 1 digital output (2A / 240Vac; source; relay contact type), 3 digital inputs (0-24Vdc), and analog inputs comprising 1 differential input (-9.8Vdc...9.8Vdc; 16-bit) and 2 single-ended inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; 10-bit conversion resolution). Additionally, it features 2 analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source; 10-bit conversion resolution). The rated active power is 4kW (5HP) under normal duty and 3kW (3HP) under heavy-duty, suitable for 3-phase input networks.
Nidec
Quick Quote
SP3202-EZ
NIDEC SP3202-EZ is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with an E.Z. Motion module and a single Safe Torque Off (STO) feature, utilizing air cooling. It has a frame size of 3, with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and supports a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The rated current is 54A under normal duty and 42A under heavy-duty conditions. This wall-mounted unit operates within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It uses the Modbus RTU RS-485 communication protocol and operates on a network frequency of 48-65 Hz (supply input) and 0-550 Hz (output). The SP3202-EZ features 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x digital inputs (0-24Vdc). It also includes 1 x analog input (-9.8Vdc...9.8Vdc; differential) with a 16-bit conversion resolution and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution, along with 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) also with a 10-bit conversion resolution. The rated active power is 15kW for normal duty and 11kW for heavy-duty, corresponding to 20HP and 15HP, respectively.
Nidec
Quick Quote
SP3201-HF
NIDEC SP3201-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in an open-loop configuration with a single Safe Torque Off (STO) and air cooling. It features a frame size 3 with dimensions of H15.32" x W9.84" x D10.23" (H389mm x W250mm x D260mm), and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The rated current is 42A under normal duty and 31A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on the supply input and 0-3000 Hz on the output. The SP3201-HF includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and analog inputs comprising 1 x (-9.8Vdc...9.8Vdc; differential) and 2 x (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution. Analog outputs include 2 x (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) with a 10-bit conversion resolution. The rated active power is 11kW for normal duty and 7.5kW for heavy-duty, corresponding to 15HP and 10HP, respectively.
Nidec
Quick Quote
M702-06400420A10101AB100
NIDEC M702-06400420A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor and dual Safe Torque Off (STO) for air cooling. It features dimensions of frame size 6, measuring H14.37" x W8.27" x D8.94" (H365mm x W210mm x D227mm). This model supports Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT communication protocols. It operates with a rated current of 48A under normal duty and 42A under heavy-duty conditions. The supply voltage required is 380Vac-480Vac (400Vac / 415Vac), and it is designed to function within an ambient air temperature range of -20°C to +40°C. The degree of protection provided is IP20, NEMA 1, UL open. It is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor) and 3 x digital outputs (2 x 100mA / 0-24Vdc source; 1 x 2A / 240Vac source; relay contact type). The rated active power is 22kW under normal duty and 18.5kW under heavy-duty, with a rated power of 30HP for both conditions.
Nidec
Quick Quote
M702-05400300A10101AB100
NIDEC M702-05400300A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor and dual Safe Torque Off (STO) for air cooling. It features dimensions of frame size 5, measuring H14.37" x W5.63" x D7.87" (H365mm x W143mm x D200mm). This model supports Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT communication protocols. It operates with a rated current of 31A under normal duty and 30A under heavy-duty conditions, and it is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac). The ambient air temperature for operation ranges from -20°C to +40°C. It has an IP20, NEMA 1, and UL open degree of protection. The device is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency of 0-599 Hz. It includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor) and 3 x digital outputs (2 x 100mA / 0-24Vdc source and 1 x 2A / 240Vac source, relay contact type). The rated active power is 15kW for both normal and heavy-duty operations, equivalent to 20HP.
Nidec
Quick Quote
M702-03400045A10101AB100
NIDEC M702-03400045A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor and dual Safe Torque Off (STO) featuring air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT communication protocols. It operates with a rated current of 6.2A under normal duty and 4.5A under heavy-duty conditions. The supply voltage required is 380Vac-480Vac (400Vac / 415Vac), and it is designed to function within an ambient air temperature range of -20°C to +40°C. The degree of protection offered is IP20, NEMA 1, UL open. It is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor) and 3 x digital outputs (2 x 100mA / 0-24Vdc source and 1 x 2A / 240Vac source, relay contact type). Its rated active power is 2.2kW under normal duty and 1.5kW under heavy-duty, corresponding to a rated power of 3HP and 2HP, respectively.
Nidec
Quick Quote
M702-03200106A10101AB100
NIDEC M702-03200106A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor and dual Safe Torque Off (STO) for air cooling. It features dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports multiple communication protocols including Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT. It operates with a rated current of 12.7A under normal duty and 10.6A under heavy-duty conditions. The supply voltage required is 200Vac-240Vac (220Vac / 230Vac), and it is designed to function within an ambient air temperature range of -20°C to +40°C. The degree of protection provided is IP20 NEMA 1 UL open. It is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor) and 3 x digital outputs (2 x 100mA / 0-24Vdc source and 1 x 2A / 240Vac source; relay contact type). The rated active power is 3kW under normal duty and 2.2kW under heavy-duty, with a rated power of 3HP for both conditions.
Nidec
Quick Quote
M702-03200050A10101AB100
NIDEC M702-03200050A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor and dual Safe Torque Off (STO) featuring air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports various communication protocols including Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT. It operates with a rated current of 6.6A under normal duty and 5A under heavy-duty conditions. The supply voltage required is AC 200Vac-240Vac (220Vac / 230Vac), and it is designed to function within an ambient air temperature range of -20°C to +40°C. The degree of protection provided is IP20, NEMA 1, UL open. It is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor), 2 x digital outputs (100mA / 0-24Vdc; source), and 1 x digital output (2A / 240Vac; source; relay contact type). The rated active power is 1.1kW under normal duty and 0.75kW under heavy-duty, with corresponding rated power of 1.5HP / 1-1/2HP (Normal duty) and 1HP (Heavy-duty).
Nidec
Quick Quote
M702-03200066A10101AB100
NIDEC M702-03200066A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M702 series designed with a built-in brake transistor and dual Safe Torque Off (STO) for air cooling. It features dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports multiple communication protocols, including Ethernet, Ethernet/IP, Modbus TCP, and PROFINET RT. It operates with a rated current of 8A under normal duty and 6.6A under heavy-duty conditions, with a supply voltage range of 200Vac-240Vac (220Vac / 230Vac). The ambient air temperature for operation ranges from -20°C to +40°C, and it has a degree of protection rated at IP20, NEMA 1, UL open. The device is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor), 2 x digital outputs (100mA / 0-24Vdc; source), and 1 x digital output (2A / 240Vac; source; relay contact type). The rated active power is 1.5kW under normal duty and 1.1kW under heavy-duty, with corresponding rated power of 2HP and 1.5HP / 1-1/2HP, respectively.
Nidec
Quick Quote
M701-11602380E10101AB100
NIDEC M701-11602380E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates with a communication protocol of RS-485 Modbus RTU. The rated current is 275A under normal duty and 238A under heavy-duty conditions, with a supply voltage range of 500Vac-690Vac (600Vac). It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This VSD/VFD supports a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 250kW under normal duty and 200kW under heavy-duty, with rated power of 300HP (Normal duty) and 250HP (Heavy-duty).
Nidec
Quick Quote
M701-11502850E10101AB100
NIDEC M701-11502850E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and utilizes the RS-485 Modbus RTU communication protocol. The rated current is 315A for Normal duty and 285A for Heavy-duty, with a supply voltage range of 500Vac-575Vac. It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This VSD/VFD is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs with varying specifications for signal types and conversion resolutions. The rated active power is 250kW for Normal duty and 225kW for Heavy-duty, corresponding to 350HP and 300HP, respectively.
Nidec
Quick Quote