CFW500B10P0T4DB20Y2
WEG CFW500B10P0T4DB20Y2 - DRIVE CFW500B10P0T4DB20Y2, CFW500/700 Drives
WEG
Quick Quote
CFW500B16P0T2DB20Y2
WEG CFW500B16P0T2DB20Y2 - DRIVE CFW500B16P0T2DB20Y2, CFW500/700 Drives
WEG
Quick Quote
CFW500C01P7T5DBN1
WEG CFW500C01P7T5DBN1 - DRIVE CFW500C01P7T5DBN1, CFW500/700 Drives
WEG
Quick Quote
3G3AX-RX2-PG01
Omron 3G3AX-RX2-PG01 - RX2 Encoder Card
Omron
Quick Quote
M701-10202830E10101AN100
NIDEC M701-10202830E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) feature, requiring an external choke and air cooling for operation. It has dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 325A under normal duty and 283A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 90kW under normal duty and 75kW under heavy-duty, with a rated power of 125HP and 100HP, respectively.
Nidec
Quick Quote
M701-09601040E10101AN100
NIDEC M701-09601040E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke and air cooling for operation. It features a frame size of 9E with dimensions of H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can operate in ambient air temperatures ranging from -20°C to +40°C. The drive offers an IP20 NEMA 1 UL open degree of protection and is suitable for 3-phase input networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (including one 2A / 240Vac; source; relay contact type), and 3 analog inputs with varying conversion resolutions and signal types. The rated active power is 110kW for normal duty and 90kW for heavy-duty applications, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M701-09601310E10101AB100
NIDEC M701-09601310E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 155A under normal duty and 131A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input (3P) network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; with different conversion resolutions and input types). The rated active power is 132kW under normal duty and 110kW under heavy-duty, with corresponding rated powers of 175HP and 150HP, respectively.
Nidec
Quick Quote
M701-09601040A10101AB100
NIDEC M701-09601040A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection is IP20 NEMA 1 UL open, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 110kW under normal duty and 90kW under heavy-duty, with a rated power of 150HP (normal duty) and 125HP (heavy-duty).
Nidec
Quick Quote
M701-09501040A10101AB100
NIDEC M701-09501040A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and air cooling. It features dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It requires a supply voltage of 500Vac-575Vac and is designed to function within an ambient air temperature range of -20°C to +40°C. The degree of protection is IP20 NEMA 1 UL open, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 1 x analog input (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution), and 2 x analog inputs (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 110kW for normal duty and 75kW for heavy-duty, with rated power of 125HP under normal duty and 100HP under heavy-duty conditions.
Nidec
Quick Quote
M701-09501040E10101AB100
NIDEC M701-09501040E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-575Vac and can function within an ambient air temperature range of -20°C to +40°C. The device offers a degree of protection rated at IP20 NEMA 1 UL open and is compatible with a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 110kW for normal duty and 75kW for heavy-duty, with rated power of 125HP under normal duty and 100HP under heavy-duty conditions.
Nidec
Quick Quote
M701-09402240A10101AB100
NIDEC M701-09402240A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 266A under normal duty and 224A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection is IP20 NEMA 1 UL open, and it is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs including 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). It has a rated active power of 132kW under normal duty and 110kW under heavy-duty, equivalent to 200HP and 150HP respectively.
Nidec
Quick Quote
M701-09202190E10101AB100
NIDEC M701-09202190E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 266A under normal duty and 219A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 75kW under normal duty and 55kW under heavy-duty, with a rated power of 100HP (normal duty) and 75HP (heavy-duty).
Nidec
Quick Quote
M701-08500630A10101AB100
NIDEC M701-08500630A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 8, measuring H29.65" x W12.21" x D11.42" (H753mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 86A under normal duty and 63A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it includes 1 analog input (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 75kW under normal duty and 45kW under heavy-duty, with a rated power of 75HP (normal duty) and 60HP (heavy-duty).
Nidec
Quick Quote
M701-08401340A10101AB100
NIDEC M701-08401340A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 8, measuring H29.65" x W12.21" x D11.42" (H753mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 155A under normal duty and 134A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection offered is IP20 NEMA 1 UL open. It is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 x digital inputs (0-24Vdc), 4 x digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 x analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). It has a rated active power of 75kW under normal duty and 55kW under heavy-duty, with a rated power of 100HP for both conditions.
Nidec
Quick Quote
M701-07600540A10101AB100
NIDEC M701-07600540A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 7, measuring H20" x W10.63" x D11.02" (H508mm x W270mm x D280mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 73A under normal duty and 54A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a network frequency of 45-66 Hz (supply input) and output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs including 1 x (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 55kW for normal duty and 45kW for heavy-duty, with corresponding rated power of 75HP and 60HP, respectively.
Nidec
Quick Quote
M701-07400660A10101AB100
NIDEC M701-07400660A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 7, measuring H20" x W10.63" x D11.02" (H508mm x W270mm x D280mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 79A under normal duty and 66A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection is IP20 NEMA 1 UL open, and it is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. The device features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). It also includes 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 37kW for normal duty and 30kW for heavy-duty, with a rated power of 50HP for both conditions.
Nidec
Quick Quote
M701-07200750A10101AB100
NIDEC M701-07200750A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and air cooling. It features dimensions of frame size 7, measuring H20" x W10.63" x D11.02" (H508mm x W270mm x D280mm), and utilizes the RS-485 Modbus RTU communication protocol. The rated current is 94A under normal duty and 75A under heavy-duty conditions, with a supply voltage range of 200Vac-240Vac (220Vac / 230Vac). It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This VSD/VFD is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it features 3 analog inputs with varying conversion resolutions and configurations. The rated active power is 22kW under normal duty and 18.5kW under heavy-duty, corresponding to 30HP and 25HP, respectively.
Nidec
Quick Quote
M701-06500150A10101AB100
NIDEC M701-06500150A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 6, measuring H14.37" x W8.27" x D8.94" (H365mm x W210mm x D227mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 17A under normal duty and 15A under heavy-duty conditions. It requires a supply voltage of 500Vac-575Vac and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs including 1 x (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 11kW for normal duty and 7.5kW for heavy-duty, with corresponding rated power of 15HP and 10HP, respectively.
Nidec
Quick Quote
M701-06500100A10101AB100
NIDEC M701-06500100A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series, designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 6, measuring H14.37" x W8.27" x D8.94" (H365mm x W210mm x D227mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 12A under normal duty and 10A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x additional digital inputs (0-24Vdc), and 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog input configuration includes 1 x analog input (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x analog inputs (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). It has a rated active power of 7.5kW under normal duty and 5.5kW under heavy-duty, with corresponding rated power of 10HP and 7.5HP / 7-1/2HP, respectively.
Nidec
Quick Quote
M701-05500069A10101AB100
NIDEC M701-05500069A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling for temperature management. It has dimensions of frame size 5, measuring H14.37" x W5.63" x D7.87" (H365mm x W143mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 10A under normal duty and 6.9A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can function within an ambient air temperature range of -20°C to +40°C. The device offers a degree of protection rated at IP20 NEMA 1 UL open and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it includes 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 5.5kW for normal duty and 4kW for heavy-duty, with a rated power of 7.5HP / 7-1/2HP for normal duty and 5HP for heavy-duty applications.
Nidec
Quick Quote
Items per page: