Filters
Manufacturer
Variable Frequency Drives (VFD)
part#
description
manufacturer
C200-07200610A10101AB100
NIDEC C200-07200610A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 75A for Normal duty and 61A for Heavy-duty. It supports Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 18.5kW for Normal duty and 15kW for Heavy-duty, with a rated power of 25HP for Normal duty and 20HP for Heavy-duty.
Nidec
Quick Quote
C200-03200100A10101AB100
NIDEC C200-03200100A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 3 H8.9" x W3.54" x D6.3" (H226mm x W90mm x D160mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 10A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol and can be used with either single-phase input (2P) or 3-phase input (3P) networks, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 2.2kW, and the rated power is 3HP for both normal and heavy-duty applications.
Nidec
Quick Quote
VFD022C53A-21
Variable Frequency Drive, 3 phase, 575 VAC Input, 2 HP, frame A, wall mount, IP20, NEMA 1
Delta
Quick Quote
VFD055C23B-21
Variable Frequency Drive, 3 phase, 230 VAC Input, 7.5 HP, frame B, wall mount, IP20, NEMA 1
Delta
Quick Quote
VFD110C4EB-21
Variable Frequency Drive, 3 phase, 460 VAC build-in EMI Input, 15 HP, frame B, wall mount, IP20, NEMA 1
Delta
Quick Quote
VFD220C23C-21
Variable Frequency Drive, 3 phase, 230 VAC Input, 30 HP, frame C, IP20, NEMA 1
Delta
Quick Quote
VFD185C23C-21
Variable Frequency Drive, 3 phase, 230 VAC Input, 25 HP, frame C, IP20, NEMA 1
Delta
Quick Quote
VFD150C4EC-21
Variable Frequency Drive, 3 phase, 460 VAC build-in EMI Input, 25 HP, frame C, IP20, NEMA 1
Delta
Quick Quote
VFD185C63C-21
Variable Frequency Drive, 3 phase, 690 VAC Input, 15 HP, frame C, IP20, NEMA 1
Delta
Quick Quote
VFD370C63C-21
Variable Frequency Drive, 3 phase, 690 VAC Input, 30 HP, frame C, IP20, NEMA 1
Delta
Quick Quote
ESV152N04TXC-CC
Lenze Drive
Lenze
Quick Quote
ESV371N04TLC
Lenze ESV371N04TLC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. The digital inputs consist of 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP functions, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions include earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Its design incorporates a built-in EMC filter, a built-in disconnect switch, and utilizes natural convection cooling (fan-less) suitable for indoor use only. The supply voltage is rated at 400Vac / 480Vac with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not have a communication interface. The rated current is 1.3A at 400Vac and 1.1A at 480Vac, for a 3-phase network. The rated active power is 0.37kW, and the rated power is 1/2HP for both 400-480Vac.
Lenze
Quick Quote
ESV751N01SXC
Lenze ESV751N01SXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H203mm x W160mm x D114mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size R1 with natural convection cooling (fan-less). The supply voltage is 120Vac / 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 4.2A for both 120Vac and 240Vac, supporting a single-phase / 1P network. The rated active power is 0.75kW, and the rated power is 1HP for both 120Vac-240Vac.
Lenze
Quick Quote
CFW700E0107T5NB20C3
DRIVE CFW700E0107T5NB20C3
WEG
Quick Quote
CFW500A02P6S2NB20
DRIVE CFW500A02P6S2NB20
WEG
Quick Quote
CFW500A01P6S2NB20G2
DRIVE CFW500A01P6S2NB20G2
WEG
Quick Quote
CFW300A04P2S2NB20
DRIVE CFW300A04P2S2NB20
WEG
Quick Quote
CFW110312T4SZ
DRIVE CFW110312T4SZ
WEG
Quick Quote
CFW110125T6ON1NBYZ
DRIVE CFW110125T6ON1NBYZ
WEG
Quick Quote
CFW110007T4ON1Z-PGM
DRIVE CFW110007T4ON1Z-PGM
WEG
Quick Quote
Items per page: