Filters
Manufacturer
Variable Frequency Drives (VFD)
part#
description
manufacturer
M701-10601780E10101AN100
NIDEC M701-10601780E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and supports RS-485 Modbus RTU communication protocol. The drive operates with a rated current of 197A under normal duty and 178A under heavy-duty conditions, and it is designed for a supply voltage of 500Vac-690Vac (600Vac). It can function within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This model is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 differential and 2 single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 185kW for normal duty and 160kW for heavy-duty, equivalent to 250HP and 200HP, respectively.
Nidec
Quick Quote
M701-10601500E10101AN100
NIDEC M701-10601500E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features a frame size of 10E with dimensions of H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 172A under normal duty and 150A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it has 3 analog inputs with an 11-bit conversion resolution. The rated active power is 160kW for normal duty and 132kW for heavy-duty, corresponding to a rated power of 200HP and 175HP, respectively.
Nidec
Quick Quote
M701-10501900E10101AB100
NIDEC M701-10501900E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 200A under normal duty and 190A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-575Vac, can function within an ambient air temperature range of -20°C to +40°C, and offers a degree of protection rated at IP20 NEMA 1 UL open. The device accommodates a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 150kW for normal duty and 132kW for heavy-duty, with a rated power of 200HP for both operating conditions.
Nidec
Quick Quote
M701-10501900E10101AN100
NIDEC M701-10501900E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke and air cooling. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and operates with a communication protocol of RS-485 Modbus RTU. The rated current is 200A under normal duty and 190A under heavy-duty conditions, with a supply voltage range of 500Vac-575Vac. It is designed to operate in ambient air temperatures ranging from -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This inverter supports a 3-phase input network with a frequency range of 45-66 Hz for supply input and 0-599 Hz for output. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs with varying conversion resolutions. The rated active power is 150kW for normal duty and 132kW for heavy-duty, with a rated power of 200HP for both conditions.
Nidec
Quick Quote
M701-10402700E10101AN100
NIDEC M701-10402700E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke and air cooling. It has dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 320A under normal duty and 270A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection offered is IP20 NEMA 1 UL open, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 160kW for normal duty and 132kW for heavy-duty, with a rated power of 250HP under normal duty and 200HP under heavy-duty conditions.
Nidec
Quick Quote
M701-10203000E10101AB100
NIDEC M701-10203000E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 360A under normal duty and 300A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 110kW for normal duty and 90kW for heavy-duty, with rated power of 150HP and 125HP, respectively.
Nidec
Quick Quote
M701-09501310A10101AB100
NIDEC M701-09501310A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and air cooling. It features dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 150A under normal duty and 131A under heavy-duty conditions. It requires a supply voltage of 500Vac-575Vac and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs, with various specifications detailed for each. The rated active power is 110kW for normal duty and 90kW for heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M701-09402000A10101AB100
NIDEC M701-09402000A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series, designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 221A under normal duty and 200A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it includes 3 analog inputs (1 differential and 2 single-ended; both with 11-bit conversion resolution). The rated active power is 110kW under normal duty and 90kW under heavy-duty, with a rated power of 150HP for both conditions.
Nidec
Quick Quote
M701-09201760E10101AN100
NIDEC M701-09201760E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a single Safe Torque Off (STO) and requires an external choke and air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 216A under normal duty and 176A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection offered is IP20 NEMA 1 UL open, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x additional digital inputs (0-24Vdc), and 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog input configuration consists of 1 x analog input (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x analog inputs (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). It has a rated active power of 55kW under normal duty and 45kW under heavy-duty, corresponding to 75HP and 60HP, respectively.
Nidec
Quick Quote
M701-08500860A10101AB100
NIDEC M701-08500860A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 8, measuring H29.65" x W12.21" x D11.42" (H753mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 108A under normal duty and 86A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x additional digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 1 x analog input (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution), and 2 x analog inputs (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 90kW under normal duty and 55kW under heavy-duty, with a rated power of 100HP (normal duty) and 75HP (heavy-duty).
Nidec
Quick Quote
M701-08401570A10101AB100
NIDEC M701-08401570A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 8, measuring H29.65" x W12.21" x D11.42" (H753mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 184A under normal duty and 157A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a network frequency of 45-66 Hz (supply input) and output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 x digital inputs (0-24Vdc), 4 x digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 x analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 90kW for normal duty and 75kW for heavy-duty, with a rated power of 125HP for both conditions.
Nidec
Quick Quote
M701-08201320A10101AB100
NIDEC M701-08201320A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and air cooling. It features dimensions of frame size 8, measuring H29.65" x W12.21" x D11.42" (H753mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 180A under normal duty and 132A under heavy-duty conditions. It requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 1 x digital output 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 45kW under normal duty and 37kW under heavy-duty, with a rated power of 60HP and 50HP, respectively.
Nidec
Quick Quote
M701-07600290A10101AB100
NIDEC M701-07600290A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 7, measuring H20" x W10.63" x D11.02" (H508mm x W270mm x D280mm), and supports RS-485 Modbus RTU communication protocol. The drive operates with a rated current of 36A under normal duty and 29A under heavy-duty conditions, and it is designed for a supply voltage of 500Vac-690Vac (600Vac). It can function in ambient air temperatures ranging from -20°C to +40°C and has a degree of protection of IP20 NEMA 1 UL open. This model is suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs including 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 30kW for normal duty and 22kW for heavy-duty, corresponding to a rated power of 40HP and 30HP, respectively.
Nidec
Quick Quote
M701-07500550A10101AB100
NIDEC M701-07500550A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling for temperature management. It has dimensions of frame size 7, measuring H20" x W10.63" x D11.02" (H508mm x W270mm x D280mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 73A under normal duty and 55A under heavy-duty conditions. It requires a supply voltage of 500Vac-575Vac and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it includes 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 55kW for normal duty and 37kW for heavy-duty, corresponding to a rated power of 60HP and 50HP, respectively.
Nidec
Quick Quote
SP6401-HF
NIDEC SP6401-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in open-loop configurations, featuring a single Safe Torque Off (STO) and air cooling. It has dimensions of frame size 6, measuring H46.02" x W12.2" x D11.73" (H1169mm x W310mm x D298mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) with a rated current of 205A for Normal duty and 180A for Heavy-duty. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and offers a degree of protection of IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on the supply input and 0-3000 Hz on the output. The SP6401-HF includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc), alongside 1 x analog input (-9.8Vdc...9.8Vdc; differential) and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution. It also features 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) with a 10-bit conversion resolution. The rated active power is 110kW for Normal duty and 90kW for Heavy-duty, with a rated power of 150HP for both Normal and Heavy-duty applications.
Nidec
Quick Quote
SP6401
NIDEC SP6401 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with a single Safe Torque Off (STO) and air cooling. It features a frame size of 6, measuring H46.02" x W12.2" x D11.73" (H1169mm x W310mm x D298mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The rated current is 205A under normal duty and 180A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol and operates on a network frequency of 48-65 Hz (supply input) and 0-550 Hz (output). The SP6401 includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). Analog interface comprises 1 x analog input (-9.8Vdc...9.8Vdc; differential) with a 16-bit conversion resolution and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution, along with 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) also with a 10-bit conversion resolution. It is designed for a 3-phase input network and delivers a rated active power of 110kW under normal duty and 90kW under heavy-duty, equivalent to 150HP for both duty types.
Nidec
Quick Quote
SP5402-HF
NIDEC SP5402-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in open-loop configurations, featuring a single Safe Torque Off (STO) and air cooling. It has a frame size of 5, measuring H33.75" x W12.2" x D11.73" (H857mm x W310mm x D298mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The rated current is 168A under normal duty and 156A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on the supply input and an output frequency range of 0-3000 Hz. The device includes 3 digital outputs (0-24Vdc; source), 1 digital output (2A / 240Vac; source; relay contact type), 3-phase input, 6 digital inputs (0-24Vdc), and 3 analog inputs with varying specifications. Additionally, it features 2 analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source; 10-bit conversion resolution). The rated active power is 90kW for normal duty and 75kW for heavy-duty, with a rated power of 125HP for both duty types.
Nidec
Quick Quote
SP4401-HF
NIDEC SP4401-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in open-loop configurations, including a single Safe Torque Off (STO) and air cooling. It features a frame size of 4, with dimensions H21.53" x W12.2" x D11.73" (H547mm x W310mm x D298mm), and operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac). The rated current is 68A under normal duty and 60A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on the supply input and 0-3000 Hz on the output. The SP4401-HF includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). Analog interface options include 1 x analog input (-9.8Vdc...9.8Vdc; differential) with 16-bit conversion resolution and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with 10-bit conversion resolution, alongside 2 x analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) also with 10-bit conversion resolution. The rated active power is 37kW under normal duty and 30kW under heavy-duty, with a rated power of 50HP for both conditions.
Nidec
Quick Quote
SP4201
NIDEC SP4201 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed with a single Safe Torque Off (STO) and air cooling. It features a frame size of 4, with dimensions H21.53" x W12.2" x D11.73" (H547mm x W310mm x D298mm), and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The SP4201 is rated for a current of 68A under normal duty and 56A under heavy-duty conditions. It is designed for wall-mounted installation and can operate within an ambient air temperature range of 0°C to +40°C. This model offers an IP20 NEMA 1 degree of protection and supports Modbus RTU RS-485 communication protocol. The network frequency ranges from 48-65 Hz for supply input and 0-550 Hz for output. It includes 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), 3 x digital inputs (0-24Vdc), and 3 x additional digital inputs (0-24Vdc). The analog interface comprises 1 x analog input (-9.8Vdc to 9.8Vdc; differential) with 16-bit conversion resolution and 2 x analog inputs (0-20mA / 4-20mA / -9.8Vdc to 9.8Vdc; single-ended) with 10-bit conversion resolution, along with 2 x analog outputs (0-20mA / 4-20mA / -10Vdc to 10Vdc; single-ended; source) also with 10-bit conversion resolution. It is rated for an active power of 18.5kW under normal duty and 15kW under heavy-duty, equivalent to 25HP and 20HP respectively.
Nidec
Quick Quote
SP4201-HF
NIDEC SP4201-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in open-loop configurations, featuring a single Safe Torque Off (STO) and air cooling. This unit, with dimensions of frame size 4 H21.53" x W12.2" x D11.73" (H547mm x W310mm x D298mm), operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and offers a rated current of 68A under normal duty and 56A under heavy-duty conditions. It is designed for wall-mounted installations and can operate in ambient air temperatures ranging from 0°C to +40°C. The SP4201-HF is protected by an IP20 NEMA 1 enclosure and utilizes Modbus RTU RS-485 for communication. It supports a network frequency from 48-65 Hz on the supply input and can output frequencies from 0 to 3000 Hz. The drive includes 3 digital outputs (0-24Vdc; source), 1 digital output (2A / 240Vac; source; relay contact type), 3 digital inputs (0-24Vdc), and 3 additional digital inputs (0-24Vdc). Analog interface options include 1 analog input (-9.8Vdc...9.8Vdc; differential) with a 16-bit conversion resolution and 2 analog inputs (0-20mA / 4-20mA / -9.8Vdc...9.8Vdc; single-ended) with a 10-bit conversion resolution, alongside 2 analog outputs (0-20mA / 4-20mA / -10Vdc...10Vdc; single-ended; source) also with a 10-bit conversion resolution. It is designed for a 3-phase input network and delivers a rated active power of 18.5kW under normal duty and 15kW under heavy-duty, equivalent to 25HP and 20HP respectively.
Nidec
Quick Quote
Items per page: