Filters
Manufacturer
Variable Frequency Drives (VFD)
part#
description
manufacturer
F600-06500120A10101AB653
NIDEC F600-06500120A10101AB653 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for 3-phase input with a supply voltage range of 500Vac-575Vac and a network frequency of 60 Hz. It features a built-in brake transistor, an internal line choke, and air cooling for its operation. The device operates within an ambient air temperature range of -20°C to +40°C and offers a degree of protection rated at IP65. It has dimensions of frame size 6, measuring H15.4" x W8.3" x D8.9" (H391mm x W210mm x D227mm). For connectivity, it includes 1 x analog input (4-20mA / 0-10Vdc; single-ended), 1 x analog output (0-10Vdc), 3 x digital inputs (24Vdc), 3 x digital inputs (0-24Vdc; configurable), and 2 x digital outputs (240Vac; relay contact type). The F600 series drive supports Modbus RTU communication protocol, has a rated current of 12A (Normal duty), a rated active power of 7.5kW (Normal duty), and a rated power of 10HP (Normal duty).
Nidec
Quick Quote
C300-02100042A10101AB100
NIDEC C300-02100042A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C300 series designed with dual Safe Torque Off (STO) and air cooling. It operates on a supply voltage of 100Vac-120Vac and has dimensions of frame size 2 H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 4.2A for both Normal and Heavy-duty operations. It supports Modbus RTU communication protocol over a single-phase input (2P) network with a frequency range of 45-66 Hz for supply input and 0-550 Hz for output. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it has 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 0.75kW and the rated power is 1HP for both Normal and Heavy-duty applications.
Nidec
Quick Quote
C300-01200024A10101AB100
NIDEC C300-01200024A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C300 series designed with dual Safe Torque Off (STO) and air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and is housed within a frame size 1, measuring H6.3" x W2.95" x D5.1" (H160mm x W75mm x D130mm), with a degree of protection rated at IP20 NEMA 1. The rated current for both normal and heavy-duty operations is 2.4A, supporting a rated active power of 0.37kW and a rated power of 1/2HP for both duty types. It features a single-phase input (2P) network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. For connectivity, it includes Modbus RTU communication protocol, 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN), 1 x digital input (0-24Vdc), 1 x digital output (50mA / 0-24Vdc; source; PWM), 1 x digital output (2A / 240Vac; source; relay contact type), and 2 x analog inputs with one supporting 0-20mA / 4-20mA / 0-10Vdc (single-ended; 11-bit conversion resolution) and the other 0-10Vdc (single-ended; 11-bit conversion resolution).
Nidec
Quick Quote
C300-01200042A10101AB100
NIDEC C300-01200042A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C300 series designed with dual Safe Torque Off (STO) and air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) with dimensions of frame size 1 H6.3" x W2.95" x D5.1" (H160mm x W75mm x D130mm) and offers a degree of protection of IP20 NEMA 1. The rated current is 4.2A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol over a single-phase input (2P) network with a frequency range of 45-66 Hz (supply input) and 0-550 Hz (output). The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it has 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 0.75kW and the rated power is 1HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C300-01200017A10101AB100
NIDEC C300-01200017A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C300 series designed with dual Safe Torque Off (STO) and air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and is housed within a frame size 1, measuring H6.3" x W2.95" x D5.1" (H160mm x W75mm x D130mm), with a degree of protection rated at IP20 NEMA 1. The rated current for both normal and heavy-duty operations is 1.7A, supporting a rated active power of 0.25kW and a rated power of 1/3HP for both duty types. It features Modbus RTU communication protocol over a single-phase input (2P) network with a frequency range of 45-66 Hz (supply input) and 0-550 Hz (output). The ambient air temperature for operation spans from -20°C to +60°C. Connectivity includes 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), 1 x digital output (50mA / 0-24Vdc; source; PWM), and 1 x digital output (2A / 240Vac; source; relay contact type). Analog inputs comprise 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution).
Nidec
Quick Quote
C200-09601310A10101AB100
NIDEC C200-09601310A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-690Vac (600Vac) and has dimensions of frame size 9A H43.62" x W12.21" x D11.42" (H1108mm x W310mm x D290mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 150A for Normal duty and 131A for Heavy-duty. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and another 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and another 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 132kW for Normal duty and 110kW for Heavy-duty, with a rated power of 175HP for Normal duty and 150HP for Heavy-duty.
Nidec
Quick Quote
C200-09402240E10101AB100
NIDEC C200-09402240E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with an external line reactor air cooling system. It operates on a supply voltage of 380Vac-480Vac, including 400Vac and 415Vac, within a frame size of 9E measuring H42.09" x W12.21" x D11.42" (H1069mm x W310mm x D290mm). This model offers a degree of protection rated at IP20 NEMA 1 and supports a rated current of 266A for Normal duty and 224A for Heavy-duty applications. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 digital output (50mA / 0-24Vdc; source; PWM) along with 1 digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 input for 0-20mA / 4-20mA / 0-10Vdc (single-ended; 11-bit conversion resolution) and another for 0-10Vdc (single-ended; 11-bit conversion resolution). This device is rated for an active power of 132kW under Normal duty and 110kW under Heavy-duty, equivalent to 200HP and 150HP respectively.
Nidec
Quick Quote
C200-09201760E10101AB100
NIDEC C200-09201760E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with an external line reactor air cooling system. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and features a frame size of 9E with dimensions H42.09" x W12.21" x D11.42" (H1069mm x W310mm x D290mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 216A for Normal duty and 176A for Heavy-duty applications. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It includes 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). The device also features 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 55kW (Normal duty) and 45kW (Heavy-duty), equivalent to 75HP (Normal duty) and 60HP (Heavy-duty).
Nidec
Quick Quote
C200-07600380A10101AB100
NIDEC C200-07600380A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-690Vac (600Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 46A under normal duty and 38A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. For connectivity, it includes 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). It also features 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 37kW under normal duty and 30kW under heavy-duty, with a rated power of 50HP (normal duty) and 40HP (heavy-duty).
Nidec
Quick Quote
C200-07600240A10101AB100
NIDEC C200-07600240A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-690Vac (600Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 30A under normal duty and 24A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 22kW under normal duty and 18.5kW under heavy-duty, with a rated power of 30HP (normal duty) and 25HP (heavy-duty).
Nidec
Quick Quote
C200-06500150A10101AB100
NIDEC C200-06500150A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), and offers a degree of protection rated at IP20 NEMA 1. The rated current is 17A under normal duty and 15A under heavy-duty conditions. It supports Modbus RTU communication protocol over a 3-phase input network, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 11kW under normal duty and 7.5kW under heavy-duty, with a rated power of 15HP (normal duty) and 10HP (heavy-duty).
Nidec
Quick Quote
C200-06400420A10101AB100
NIDEC C200-06400420A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 48A for Normal duty and 42A for Heavy-duty. It supports Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 22kW for Normal duty and 18.5kW for Heavy-duty, with a rated power of 30HP for both Normal and Heavy-duty applications.
Nidec
Quick Quote
C200-05500069A10101AB100
NIDEC C200-05500069A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-575Vac and has dimensions of frame size 5 H15.39" x W5.63" x D7.87" (H391mm x W143mm x D200mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 10A for Normal duty and 6.9A for Heavy-duty. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation is between -20°C and +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 5.5kW for Normal duty and 4kW for Heavy-duty, with a rated power of 7.5HP / 7-1/2HP for Normal duty and 5HP for Heavy-duty.
Nidec
Quick Quote
C200-03400056A10101AB100
NIDEC C200-03400056A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 3 H8.9" x W3.54" x D6.3" (H226mm x W90mm x D160mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 5.6A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol over a 3-phase input network, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 2.2kW and the rated power is 3HP for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-02400023A10101AB100
NIDEC C200-02400023A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 2 H8.07" x W2.95" x D5.9" (H205mm x W75mm x D150mm). This model offers a degree of protection of IP20 NEMA 1 and is rated for a current of 2.3A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated at 0.75kW (1HP) for both normal and heavy-duty applications.
Nidec
Quick Quote
C200-01100024A10101AB100
NIDEC C200-01100024A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 100Vac-120Vac and has dimensions of frame size 1 H6.3" x W2.95" x D5.1" (H160mm x W75mm x D130mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 2.4A for both normal and heavy-duty operations. It supports Modbus RTU communication protocol over a single-phase input (2P) network with a frequency range of 45-66 Hz for supply input and 0-550 Hz for output. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it has 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 0.25kW and the rated power is 1/2HP for both normal and heavy-duty applications.
Nidec
Quick Quote
S100-03113-0B0000
Nidec S100-03113-0B0000
Nidec
Quick Quote
S100-02S71-0B0000
Nidec S100-02S71-0B0000
Nidec
Quick Quote
S100-02S31-0B0000
Nidec S100-02S31-0B0000
Nidec
Quick Quote
F600-06400480A10101AB653
NIDEC F600-06400480A10101AB653 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for 3-phase input with a supply voltage range of 380Vac-480Vac, specifically 400Vac / 415Vac, and operates on a 60 Hz network frequency. It features a built-in brake transistor, an internal line choke, and air cooling design, ensuring operation within ambient air temperatures of -20°C to +40°C. This model, part of the F600 series, offers a degree of protection of IP65 and has dimensions of frame size 6, measuring H15.4" x W8.3" x D8.9" (H391mm x W210mm x D227mm). It is equipped with 1 analog input (4-20mA / 0-10Vdc; single-ended), 1 analog output (0-10Vdc), 3 digital inputs (24Vdc), 3 additional digital inputs (0-24Vdc; configurable), and 2 digital outputs (240Vac; relay contact type). The drive supports Modbus RTU communication protocol, has a rated current of 48A (Normal duty), rated active power of 22kW (Normal duty), and rated power of 30HP (Normal duty).
Nidec
Quick Quote
Items per page: