Filters
Manufacturer
Number of Poles
Current Rating
Voltage
SCCR
UL Standard
UL CCN
UL File No.
Molded Case Circuit Breakers (MCCB)
part#
description
manufacturer
BDL16110LH
Square D by Schneider Electric BDL16110LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 125 TMD 1P-1t design. It has a rated current of 110A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type utilizes aluminium lugs on both load and line sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with a 1-pole (1P) configuration. It measures 137 mm in height, 80 mm in depth, and 27 mm in width. The BDL16110LH is categorized under utilisation category A and features over-current protection fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. It has a rated insulation voltage (Ui) of 800 V, a rated operating voltage (Ue) of 240 V, and offers thermal and magnetic protection functions. The trip current rating is 110 AT, with a frame current rating of 125 AF. It operates via a toggle (manual) mode and has a short circuit breaking rating that varies depending on the voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL16100LH
Square D by Schneider Electric BDL16100LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 100A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. This MCCB is equipped with aluminium lugs on both load and line sides for connections and offers a degree of protection of IP40. It is designed for fixed mounting on a DIN rail or as an individual unit mount on a plate, featuring a single pole (1P) configuration. The net dimensions are 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and provides over-current protection fixed at 100A, short-circuit hold current protection fixed at 1000A, and short-circuit trip current protection fixed at 1500A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 240 V, and it includes thermal and magnetic protection functions. The trip current rating is 100 AT, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of up to 25kA at 240Vac according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL16090LH
Square D by Schneider Electric BDL16090LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 90A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. This MCCB is equipped with aluminium lugs on both load and line sides for connections and offers a degree of protection of IP40. It is designed for fixed mounting on a DIN rail or as an individual unit mount on a plate, featuring a single pole (1P) configuration. The net dimensions are 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and provides over-current protection fixed at 90A, short-circuit hold current protection fixed at 1000A, and short-circuit trip current protection fixed at 1500A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 240 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 90 AT. The MCCB has a mechanical durability of 15,000 operations at no load and an electrical durability of 10,000 operations with load at 240Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, achieving 25kA at 240Vac, 18kA at both 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac under UL489 standards, and 10kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL16080LH
Square D by Schneider Electric BDL16080LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 80A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type utilizes aluminium lugs on both load and line sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, and it is a 1-pole (1P) device with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features over-current protection fixed at 80A, short-circuit hold current protection fixed at 800A, and short-circuit trip current protection fixed at 1200A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 240 V, and it includes thermal and magnetic protection functions for overload and short-circuit, respectively. The trip current rating is 80 AT, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL16070LH
Square D by Schneider Electric BDL16070LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 70A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. This MCCB is equipped with aluminium lugs on both load and line sides for connections and offers a degree of protection of IP40. It is designed for fixed mounting on DIN rail or as an individual unit mount on a plate. The breaker has a 1-pole (1P) configuration, with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features over-current protection fixed at 70A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 240 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 70 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In, and it has a mechanical durability of 15,000 operations at no load. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, offering 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL16060LH
Square D by Schneider Electric BDL16060LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 60A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type utilizes aluminium lugs on both load and line sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with a 1-pole (1P) configuration. It measures 137 mm in height, 80 mm in depth, and 27 mm in width. The BDL16060LH is categorized under utilisation category A and features over-current protection fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. It also provides thermal protection against overload and magnetic protection against short-circuit, with a trip current rating of 60 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In, and it has a mechanical durability of 15,000 operations at no load. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, offering 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all in accordance with UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL16050LH
Square D by Schneider Electric BDL16050LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 50A 600Y/347Vac 14kA design with aluminium lugs. It has a rated impulse voltage (Uimp) of 8 kV and offers a connection type with aluminium lugs on both load and line sides. The degree of protection is IP40, with a rated current of 50A and a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 15,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 1-pole (1P) device with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. The utilisation category is A, and it includes protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 50 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL16045LH
Square D by Schneider Electric BDL16045LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range. It features a PowerPact B-Frame 100 TMD 1P-1t design, with a rated current of 45A and a rated voltage of 600Vac 600Y/347Vac. This MCCB has an impulse voltage rating (Uimp) of 8 kV and offers a degree of protection of IP40. It is equipped with aluminium lugs for connection on both load and line sides. The BDL16045LH is designed for fixed mounting on a DIN rail or as an individual unit mount on a plate, and it has a 1-pole (1P) configuration. The net dimensions are 137 mm in height, 80 mm in depth, and 27 mm in width. It operates with a utilisation category of A and has mechanical durability of 15,000 operations at no load. The protection settings include over-current fixed at 45A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. It also features thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 45 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL16040LH
Square D by Schneider Electric BDL16040LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range. It features a PowerPact B-Frame 100 TMD 1P-1t 40A 600Y/347Vac 14kA design with aluminium lugs for connection on both load and line sides. This MCCB has a rated impulse voltage (Uimp) of 8 kV and offers a degree of protection of IP40. It is designed for a rated current of 40A and a rated voltage (AC) of 600Vac 600Y/347Vac. The mechanical durability of this unit is 15,000 operations at no load, with a fixed mounting mode on DIN rail or individual unit mount on plate. It is a 1-pole (1P) device with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. The utilisation category is A, and it includes protection settings for over-current fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 40 AT. The electrical durability with load is 10,000 operations at 240Vac; In. It has a frame current rating of 100 AF and operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDL16035LH
Square D by Schneider Electric BDL16035LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range. It features a PowerPact B-Frame 100 TMD 1P-1t design with a rated current of 35A and a rated voltage of 600Vac 600Y/347Vac. This MCCB has an impulse voltage rating of 8 kV and offers a degree of protection of IP40. It is equipped with aluminium lugs on both load and line sides for connections. The BDL16035LH is designed for fixed mounting on a DIN rail or as an individual unit mount on a plate, and it has a 1-pole (1P) configuration. The dimensions are 137 mm in height, 80 mm in depth, and 27 mm in width. It operates with a utilisation category of A and provides over-current protection fixed at 35A, short-circuit hold current protection fixed at 400A, and short-circuit trip current protection fixed at 600A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 240 V, and it also has a DC rated voltage of 125Vdc. The MCCB offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 35 AT. Its mechanical durability is rated at 15,000 operations at no load, and its electrical durability with load is 10,000 operations at 240Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking ratings are 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards, with a 10kA rating at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL16030LH
Square D by Schneider Electric BDL16030LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 30A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type includes aluminium lugs on both load and line sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on a DIN rail or as an individual unit mount on a plate, with a 1-pole (1P) configuration. It measures 137 mm in height, 80 mm in depth, and 27 mm in width. The BDL16030LH is categorized under utilisation category A and features over-current protection fixed at 30A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. It also provides thermal protection against overload and magnetic protection against short-circuits, with a trip current rating of 30 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In, and it has a mechanical durability of 15,000 operations at no load. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac according to UL489 standards, and 10kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL16025LH
Square D by Schneider Electric BDL16025LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 25A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. This MCCB is equipped with aluminium lugs on both load and line sides for connections and offers a degree of protection of IP40. It is designed for fixed mounting on DIN rail or individual unit mount on plate, with a 1-pole (1P) configuration. The MCCB has a net height of 137 mm, a net depth of 80 mm, and a net width of 27 mm. It falls under utilisation category A and features over-current protection fixed at 25A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 240 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 25 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In, and it has a mechanical durability of 15,000 operations at no load. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, up to 25kA at 240Vac according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric
Quick Quote
BDL16020LH
Square D by Schneider Electric BDL16020LH is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t design. It has a rated current of 20A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type utilizes aluminium lugs on both load and line sides, and it offers a degree of protection of IP40. This MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with a single pole (1P) configuration. It measures 137 mm in height, 80 mm in depth, and 27 mm in width. The BDL16020LH is categorized under utilisation category A and features over-current protection fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. It also provides thermal protection against overload and magnetic protection against short-circuits, with a trip current rating of 20 AT. The electrical durability with load is rated at 10,000 operations at 240Vac; In, and it has a mechanical durability of 15,000 operations at no load. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, achieving 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all in accordance with UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDF26090
Square D by Schneider Electric BDF26090 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design. It has a rated current of 90A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, offering a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. It has 2 poles (2P) and falls under the utilization category A. The dimensions are 137 mm in height, 80 mm in depth, and 54 mm in width. Its protection settings include over-current fixed at 90A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated insulation voltage (Ui) is 800 V, with a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 90 AT. The electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDA141251
Square D by Schneider Electric BDA141251 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 125 TMD 1P 125A 480Y/277Vac 18kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection (A phase) with a degree of protection rated at IP40. The rated current is 125A, with AC rated voltage at 480Vac 480Y/277Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It is a 1-pole (1P) device with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 125 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 25kA at 240Vac; UL489, 18kA at both 480Vac; UL489 and 480Y/277Vac; UL489, 14kA at 600Y/347Vac; UL489, and 10kA at 250Vdc; UL489. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
BDA141101
Square D by Schneider Electric BDA141101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 125 TMD 1P 110A design for 480Y/277Vac with an 18kA I-line and an 80% rating. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for the A phase. This MCCB offers a degree of protection of IP40 and supports a rated current of 110A with a rated voltage (AC) of 480Vac 480Y/277Vac. It is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. The device is a 1-pole (1P) unit with dimensions of 137 mm in height, 89 mm in depth, and 27 mm in width. It falls under utilisation category A and features over-current protection fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 110 AT. Its electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric
Quick Quote
S174A
Square D by Schneider Electric S174A is a Micrologic 6.0H trip unit designed for use within the Micrologic Trip Unit and Options sub-range. This part functions as a trip unit alone, without additional integrated features or accessories.
Schneider Electric
Quick Quote
S163A
Square D by Schneider Electric S163A is a trip unit categorized under the Micrologic Trip Unit and Options sub-range. This product functions as a trip unit alone, specifically designed as a Micrologic 5.0P model.
Schneider Electric
Quick Quote
ACW125W-FTU15-3
WEG ACW125W-FTU15-3 - CIRCUIT BREAKER ACW125W-FTU15-3, Circuit Breakers
WEG
Quick Quote
ACW125W-FTU20-3
WEG ACW125W-FTU20-3 - CIRCUIT BREAKER ACW125W-FTU20-3, Circuit Breakers
WEG
Quick Quote
Items per page:
Molded Case Circuit Breakers (MCCB)
General Guide & Overview
Understanding the dynamics of electrical safety necessitates a thorough knowledge of molded case circuit breakers, commonly known as MCCBs. They play a crucial role in the protection against electrical hazards, including fires and shocks. But, what is a molded case circuit breaker? This protective device is meticulously crafted to interrupt current flow in the event of excessive loads, ensuring the sanctity of the electrical systems it safeguards. The significance of MCCBs can't be understated, considering they follow stringent guidelines set by the National Electrical Code® (NEC®) and align with the requirements of UL 489 standards.
Diving into what is an MCCB reveals a versatile range of products. From ground fault to arc-fault circuit interrupters and from devices catered to photovoltaic systems to robust surge-protective devices, the MCCB's adaptability is as extensive as its utility. But how does a molded case circuit breaker work? Whether utilizing classic thermal magnetic trip mechanisms or sporting advanced electronic units, MCCBs are engineered to detect and respond to thermal overloads, short circuits, and ground faults with precision. Their distinct features, prescribed by UL standards, ensure that these indispensable components fulfill their protective role in diverse applications with efficacy and reliability.
Understanding Molded Case Circuit Breakers (MCCB)
Exploring the intricate realm of electrical safety, it's essential to address a common inquiry: what is the difference between MCB and MCCB circuit breakers? Minature Circuit Breakers (MCBs) are suitable for domestic applications, offering protection to individual circuits. In contrast, Molded Case Circuit Breakers (MCCBs) serve a more robust purpose in industrial environments. This distinction is pivotal in electrical engineering, impacting how we safeguard our systems from overloads and faults.
The function of an MCCB within electrical frameworks is profound. Its core responsibility lies in integrating a temperature-sensitive element with an electromagnetic component. Together, these create a robust defense mechanism against excessive current flows. Such integration is precisely executed to promptly interrupt the circuit when potential dangers like thermal overloads, short circuits, and ground faults emerge.
Evaluating MCCB vs MCB, one can recognize the vast capabilities of MCCBs to handle higher power systems and a broader range of current ratings. The MCCB's construction is a matrix of precision-engineered mechanisms designed to detect abnormal currents. A bimetallic strip within the breaker warms up under excessive current flow, bending to instigate a trip action - a fundamental aspect of what is the MCCB function.
Imagine a scenario where high currents surge through a system due to an insulation failure. Here, the MCCB's electromagnet responds instantaneously, actuating a trip and consequently mitigating the risk of damage. The difference between MCB and MCCB becomes apparent in their response to these events, emphasizing the latter's suitability for comprehensive protection in more demanding electrical infrastructures.
The evolution of MCCBs embraces the incorporation of ground fault protection directly into the trip unit, highlighting their advanced capabilities. Embracing such advancements ensures that MCCBs remain at the forefront of circuit protection technology. Fully grasping the mccb in electrical systems means recognizing its essential role in maintaining the integrity and safety of today's complex power networks.
Molded Case Circuit Breakers (MCCB) in Electrical Systems
The protection and management of electrical systems are pivotal, and when dissecting the intricacies of these systems, one frequently encounters the comparison of mcb vs mccb. The distinction between the two is substantial, with MCCBs bearing a design for higher capacity and adaptability, a clear choice for comprehensive system protection. A crucial feature, the mccb function, resides in its ability to safeguard against various fault conditions while supporting multiple applications, from residential complexes to grand scale industrial layouts. In essence, understanding what is molded case circuit breaker invites recognition of a device formed to interrupt excessive currents swiftly, thereby preserving the integrity of the electrical circuit it serves.
At the core of their operation, MCCBs are engineered to be resilient. They exhibit a multitude of trip characteristics suitable for unique environments and load profiles. Whether it be a surge within a domestic dwelling or an industrious leap in an assembly line, the MCCB interrupts these irregular currents promptly to avert probable mishaps. This dynamic performance, teamed with their adaptability, underscores the importance of mccb application in diverse electrical systems, affirming their role as indispensable components in modern power management and safety frameworks.
Advancements in technology have ensured that MCCBs are not left behind. Their proficiency now extends to safeguarding systems integrative of renewable energies, such as photovoltaic setups, and those reliant on novel power storage solutions. Given their inherent modular structure, these circuit breakers provide flexibility and reliability, reflecting their readiness to evolve in step with electrical advancements. The divergent milieu of electrical environments finds a common sentinel in MCCBs, echoing their universal presence and paramount significance in electrical safety.
FAQ
What is a Molded Case Circuit Breaker (MCCB)?
An MCCB is a type of electrical protection device that can automatically cut off electrical power when it detects an overload, short circuit, or ground fault. It's designed to protect an electrical circuit from damage caused by excess current resulting from an overload or a short circuit.
How does a Molded Case Circuit Breaker work?
An MCCB functions by combining thermal and magnetic trip elements. The thermal component, usually a bimetal strip, responds to prolonged overload conditions by bending and triggering the trip mechanism, while the magnetic element activates almost instantly in severe short-circuit conditions to protect the circuitry.
What is the difference between MCB and MCCB?
The key difference lies in their capacity and applications. MCBs, or Miniature Circuit Breakers, are designed for lower power applications and typically offer lower interrupting current ratings. MCCBs, on the other hand, are suitable for higher power applications and can handle higher current ratings, making them ideal for industrial or commercial installations.
What does MCCB stand for?
MCCB stands for Molded Case Circuit Breaker, which refers to the type of casing that encapsulates the internal components, providing a robust barrier against mechanical and environmental factors.
What is the function of an MCCB?
The primary function of an MCCB is to provide protection by interrupting the flow of electricity in the event of an overload or a fault condition, such as a short circuit or a ground fault. It safeguards electrical circuits by preventing damage to equipment and reducing the risk of electrical fires or shocks.
What are the applications of MCCBs in electrical systems?
MCCBs are versatile and are used in a variety of electrical systems ranging from residential to industrial settings. They are essential in environments where high-rated currents are used and are ideal for circuit protection in power distribution networks, such as transformer protection, backup protection, and capacitor bank protection.