Molded Case Circuit Breakers (MCCB)
part#
description
manufacturer
LV429032
Schneider Electric LV429032 is a trip unit designed for thermal and magnetic protection. It belongs to the TMD sub-range and functions as a trip unit alone. This model is equipped with 3 poles and offers thermal protection against overload and magnetic protection against short-circuits. It has a rated current of 63A and features protection settings that are adjustable for over-current from 0.7 to 1.0 times the rated current (In), with a short-circuit pickup current fixed at 500A. The trip current rating is 63 AT, and it protects all 3 poles. The LV429032 is characterized by its TMD interchangeable thermal-magnetic adjustable type.
Schneider Electric
Quick Quote
LV429031
Schneider Electric LV429031 is a trip unit designed for thermal and magnetic protection. It belongs to the TMD sub-range and functions as a trip unit alone. This part is compatible with 3 poles and offers both thermal protection for overload scenarios and magnetic protection for short-circuit conditions. The rated current for this unit is 80A, with over-current protection settings adjustable from 0.7 to 1.0 times the nominal current (In) and a fixed short-circuit pickup current of 640A. The trip current rating stands at 80 AT, ensuring all three poles are protected. The LV429031 features an interchangeable Thermal-Magnetic (adjustable) trip unit type, catering to a variety of circuit protection needs.
Schneider Electric
Quick Quote
LV429030
Schneider Electric LV429030 is a trip unit designed for use in electrical circuit protection. It belongs to the TMD sub-range and functions solely as a trip unit. This model is equipped with three poles and offers both thermal protection for overload scenarios and magnetic protection for short-circuit conditions. It has a rated current of 100A and features protection settings that include over-current adjustability ranging from 0.7 to 1.0 times the nominal current (In) and a fixed short-circuit pickup current set at 800A. The trip current rating stands at 100 AT, with all three poles being protected. The LV429030 utilizes an interchangeable Thermal-Magnetic (TMD) trip unit type, which is adjustable to meet specific circuit protection requirements.
Schneider Electric
Quick Quote
LV429019
Schneider Electric LV429019 is a frame designed for use with NSX100S range, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and supports 4 poles. The rated current for this part is 100A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame current rating stands at 100 AF. It boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). The rated voltage (AC) phase-to-phase is 690V, and it protects 4 poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429018
Schneider Electric LV429018 is a frame designed for use with NSX100S systems, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for three poles. The rated current for this part is 100A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame current rating stands at 100 AF. It boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it is designed to protect three poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429014
Schneider Electric LV429014 is a circuit breaker frame designed for use within the NSX100B range. This frame is specifically crafted to accommodate a 3-pole configuration without a trip unit, supporting a rated current of 100A. It is engineered to withstand a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame's current rating stands at 100 AF, with a rated voltage (AC) for phase-to-phase connections up to 690V. All three poles are protected, and the trip unit type is interchangeable, classified under utilisation category A.
Schneider Electric
Quick Quote
LV429011
Schneider Electric LV429011 is a frame designed for use with NSX100N sub-range, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and supports 4 poles. The rated current for this part is 100A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame current rating stands at 100 AF. It boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and all four poles are protected. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429005
Schneider Electric LV429005 is a frame designed for use within the NSX100L sub-range, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for 3 poles with a rated current of 100A. The frame is specified with a rated insulation voltage (Ui) of 800 V and a rated impulse voltage (Uimp) of 8 kV. Its frame current rating stands at 100 AF. The LV429005 boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). It supports a rated voltage (AC) for phase-to-phase connections up to 690 V and ensures all 3 poles are protected. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV429004
Schneider Electric LV429004 is a frame designed for use within the NSX100H sub-range, functioning as a circuit breaker frame without a trip unit. It features a lug connection type and is built for 3 poles. The rated current for this part is 100A, with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The frame current rating stands at 100 AF. It boasts a mechanical durability of 50,000 operations at no load and an electrical durability of 50,000 operations at 440Vac with half the rated current (In/2), and 30,000 operations at 440Vac with the rated current (In). The rated voltage for phase-to-phase connections is 690V, and it protects 3 poles. The trip unit type is interchangeable, and it falls under utilisation category A.
Schneider Electric
Quick Quote
YA1200R3
Square D by Schneider Electric YA1200R3 is a connector within the connections sub-range, designed as an aluminum compression lugs kit suitable for 2/0AWG to 300kcmil Al wire. It has a rated current of 1200A.
Schneider Electric
Quick Quote
TRV00210
Schneider Electric TRV00210 is a communications unit categorized under the sub-range of communication accessories, designed specifically as a Modbus SL communication interface module. It utilizes the Modbus communication protocol to facilitate interactions and data exchange within automation systems.
Schneider Electric
Quick Quote
SRCTV12
Square D by Schneider Electric SRCTV12 is a connector designed for use as part of the plugin / drawout accessories sub-range. It functions as a cradle connector, specifically for Rear Connected T Horizontal/Vertical (RCTH/RCTV) applications.
Schneider Electric
Quick Quote
S64204
Square D by Schneider Electric S64204 is an auxiliary contact module designed to provide 6 programmable contacts (M6C). This component is specifically engineered to enhance the functionality of automation systems by offering additional contact options for various applications.
Schneider Electric
Quick Quote
RLTB4
Square D by Schneider Electric RLTB4 is a connector within the connections sub-range, designed as a terminal pads kit. It features 4 poles and is rated for a current of 2500A and a voltage of 250Vac. This part is compatible with the PROFIBUS PA communication protocol.
Schneider Electric
Quick Quote
LV434195
Schneider Electric LV434195 is a ULP cord designed for automation applications, featuring a length of 0.35 meters. This cable is specifically engineered to facilitate connections within Schneider Electric's range of automation products, ensuring compatibility and streamlined integration.
Schneider Electric
Quick Quote
LV433683
Schneider Electric LV433683 is a cover designed for use with electrical components, featuring short terminal shields for applications greater than 500V. It is compatible with systems requiring 3 poles.
Schneider Electric
Quick Quote
LV432475
Schneider Electric LV432475 is a connector designed for rear connections, specifically categorized under the sub-range name of rear connections. This part facilitates a short rear connection setup, aligning with its main function as a connector within automation systems.
Schneider Electric
Quick Quote
LV432455
Schneider Electric LV432455 is an earth leakage module within the Vigi MB sub-range, designed for 200-440V applications. This module features a 3-pole configuration and offers earth leakage protection with a rated insulation voltage (Ui) of 800 V and a rated impulse voltage (Uimp) of 8 kV. The residual current sensitivity is adjustable, with settings of 300; 1000; 3000; 10000; 30000mA or 0.3; 1; 3; 10; 30A, accommodating a wide range of protection requirements. It supports a rated voltage (AC) for phase-to-phase connections of 440 V. The protected poles number 3, and the module provides adjustable time delay (Tripping) options of 0; 0.06; 0.15; 0.31 seconds, allowing for tailored protection settings.
Schneider Electric
Quick Quote
LV432454
Schneider Electric LV432454 is an earth leakage module designed for use within the Vigi MB sub-range. This module is capable of handling earth leakage protection with adjustable residual current sensitivity settings of 300, 1000, 3000, 10000, and 30000mA or equivalently 0.3, 1, 3, 10, and 30A. It operates on a 440-550V AC phase-to-phase rated voltage and is equipped with 4 poles for both the main function and protection functions. The LV432454 features a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. Additionally, it offers adjustable time delay tripping settings of 0, 0.06, 0.15, and 0.31 seconds, ensuring tailored protection for various applications.
Schneider Electric
Quick Quote
LV431536
Schneider Electric LV431536 is an earth leakage module designed for use within the Vigi MH sub-range. This module supports a 4 Pole configuration and offers earth leakage protection with adjustable residual current sensitivity ranging from 30mA to 10A (0.03A to 10A). It is suitable for systems with a rated insulation voltage (Ui) of 800V and a rated impulse voltage (Uimp) of 8kV. The LV431536 operates at a phase-to-phase rated voltage (AC) of 440V and provides protection across all 4 poles. The module features an adjustable time delay for tripping, with settings of 0, 0.06, 0.15, and 0.31 seconds, accommodating various application requirements.
Schneider Electric
Quick Quote
Items per page:
Molded Case Circuit Breakers (MCCB)
General Guide & Overview
Understanding the dynamics of electrical safety necessitates a thorough knowledge of molded case circuit breakers, commonly known as MCCBs. They play a crucial role in the protection against electrical hazards, including fires and shocks. But, what is a molded case circuit breaker? This protective device is meticulously crafted to interrupt current flow in the event of excessive loads, ensuring the sanctity of the electrical systems it safeguards. The significance of MCCBs can't be understated, considering they follow stringent guidelines set by the National Electrical Code® (NEC®) and align with the requirements of UL 489 standards.
Diving into what is an MCCB reveals a versatile range of products. From ground fault to arc-fault circuit interrupters and from devices catered to photovoltaic systems to robust surge-protective devices, the MCCB's adaptability is as extensive as its utility. But how does a molded case circuit breaker work? Whether utilizing classic thermal magnetic trip mechanisms or sporting advanced electronic units, MCCBs are engineered to detect and respond to thermal overloads, short circuits, and ground faults with precision. Their distinct features, prescribed by UL standards, ensure that these indispensable components fulfill their protective role in diverse applications with efficacy and reliability.
Understanding Molded Case Circuit Breakers (MCCB)
Exploring the intricate realm of electrical safety, it's essential to address a common inquiry: what is the difference between MCB and MCCB circuit breakers? Minature Circuit Breakers (MCBs) are suitable for domestic applications, offering protection to individual circuits. In contrast, Molded Case Circuit Breakers (MCCBs) serve a more robust purpose in industrial environments. This distinction is pivotal in electrical engineering, impacting how we safeguard our systems from overloads and faults.
The function of an MCCB within electrical frameworks is profound. Its core responsibility lies in integrating a temperature-sensitive element with an electromagnetic component. Together, these create a robust defense mechanism against excessive current flows. Such integration is precisely executed to promptly interrupt the circuit when potential dangers like thermal overloads, short circuits, and ground faults emerge.
Evaluating MCCB vs MCB, one can recognize the vast capabilities of MCCBs to handle higher power systems and a broader range of current ratings. The MCCB's construction is a matrix of precision-engineered mechanisms designed to detect abnormal currents. A bimetallic strip within the breaker warms up under excessive current flow, bending to instigate a trip action - a fundamental aspect of what is the MCCB function.
Imagine a scenario where high currents surge through a system due to an insulation failure. Here, the MCCB's electromagnet responds instantaneously, actuating a trip and consequently mitigating the risk of damage. The difference between MCB and MCCB becomes apparent in their response to these events, emphasizing the latter's suitability for comprehensive protection in more demanding electrical infrastructures.
The evolution of MCCBs embraces the incorporation of ground fault protection directly into the trip unit, highlighting their advanced capabilities. Embracing such advancements ensures that MCCBs remain at the forefront of circuit protection technology. Fully grasping the mccb in electrical systems means recognizing its essential role in maintaining the integrity and safety of today's complex power networks.
Molded Case Circuit Breakers (MCCB) in Electrical Systems
The protection and management of electrical systems are pivotal, and when dissecting the intricacies of these systems, one frequently encounters the comparison of mcb vs mccb. The distinction between the two is substantial, with MCCBs bearing a design for higher capacity and adaptability, a clear choice for comprehensive system protection. A crucial feature, the mccb function, resides in its ability to safeguard against various fault conditions while supporting multiple applications, from residential complexes to grand scale industrial layouts. In essence, understanding what is molded case circuit breaker invites recognition of a device formed to interrupt excessive currents swiftly, thereby preserving the integrity of the electrical circuit it serves.
At the core of their operation, MCCBs are engineered to be resilient. They exhibit a multitude of trip characteristics suitable for unique environments and load profiles. Whether it be a surge within a domestic dwelling or an industrious leap in an assembly line, the MCCB interrupts these irregular currents promptly to avert probable mishaps. This dynamic performance, teamed with their adaptability, underscores the importance of mccb application in diverse electrical systems, affirming their role as indispensable components in modern power management and safety frameworks.
Advancements in technology have ensured that MCCBs are not left behind. Their proficiency now extends to safeguarding systems integrative of renewable energies, such as photovoltaic setups, and those reliant on novel power storage solutions. Given their inherent modular structure, these circuit breakers provide flexibility and reliability, reflecting their readiness to evolve in step with electrical advancements. The divergent milieu of electrical environments finds a common sentinel in MCCBs, echoing their universal presence and paramount significance in electrical safety.
FAQ
What is a Molded Case Circuit Breaker (MCCB)?
An MCCB is a type of electrical protection device that can automatically cut off electrical power when it detects an overload, short circuit, or ground fault. It's designed to protect an electrical circuit from damage caused by excess current resulting from an overload or a short circuit.
How does a Molded Case Circuit Breaker work?
An MCCB functions by combining thermal and magnetic trip elements. The thermal component, usually a bimetal strip, responds to prolonged overload conditions by bending and triggering the trip mechanism, while the magnetic element activates almost instantly in severe short-circuit conditions to protect the circuitry.
What is the difference between MCB and MCCB?
The key difference lies in their capacity and applications. MCBs, or Miniature Circuit Breakers, are designed for lower power applications and typically offer lower interrupting current ratings. MCCBs, on the other hand, are suitable for higher power applications and can handle higher current ratings, making them ideal for industrial or commercial installations.
What does MCCB stand for?
MCCB stands for Molded Case Circuit Breaker, which refers to the type of casing that encapsulates the internal components, providing a robust barrier against mechanical and environmental factors.
What is the function of an MCCB?
The primary function of an MCCB is to provide protection by interrupting the flow of electricity in the event of an overload or a fault condition, such as a short circuit or a ground fault. It safeguards electrical circuits by preventing damage to equipment and reducing the risk of electrical fires or shocks.
What are the applications of MCCBs in electrical systems?
MCCBs are versatile and are used in a variety of electrical systems ranging from residential to industrial settings. They are essential in environments where high-rated currents are used and are ideal for circuit protection in power distribution networks, such as transformer protection, backup protection, and capacitor bank protection.