Filters
Manufacturer
Number of Poles
Current Rating
Voltage
SCCR
UL Standard
UL CCN
UL File No.
Molded Case Circuit Breakers (MCCB)
part#
description
manufacturer
LV433331
Schneider Electric LV433331 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB2 sub-range, designed for lug connection and featuring 4 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 600A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 40 AT and a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV433317
Schneider Electric LV433317 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, designed for lug connection and equipped with three poles. It features a comprehensive suite of protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), phase unbalance or phase loss, locked rotor, under-load (under-current), long start, and ground fault protection (G). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable, with L ranging from 0.5 to 1 x In, S0 from 5 to 13 x Ir, I fixed at 1500A, and G from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The device also features a trip current rating of 100 AT, a frame current rating of 100 AF, and a rated impulse voltage (Uimp) of 8 kV. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and it protects three poles. The trip unit type is Micrologic 6.2E-M (LSIG) with an interchangeable electronic mechanism. Measurement functions include current and voltage across phases, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy consumption (kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion (THDu, THDv, THDi). It is categorized under utilisation category A.
Schneider Electric
Quick Quote
LV433316
Schneider Electric LV433316 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range. It features a lug connection type and is designed with 3 poles. The LV433316 offers a variety of protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), phase unbalance or phase loss, locked rotor, under-load (under-current), long start, and ground fault protection (G). It has a rated current of 50A and a rated insulation voltage (Ui) of 800V. The protection settings are adjustable, with long-time protection ranging from 0.5 to 1 x In, short-time protection from 5 to 13 x Ir, and ground fault protection from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The instantaneous protection is fixed at 750A. The LV433316 has a rated impulse voltage (Uimp) of 8 kV and a frame current rating of 100 AF. Its mechanical durability is rated at 20,000 operations at no load, and its electrical durability is rated at 10,000 operations at 690Vac with half the rated current and 5,000 operations at 690Vac with the rated current. The rated voltage for phase-to-phase is 690V. The trip unit type is Micrologic 6.2E-M (LSIG) which is an interchangeable electronic unit. It also includes measurement functions for current, voltage, power, energy, demand current/power with an adjustable time window, and total harmonic distortion among others. The utilisation category for this MCCB is A.
Schneider Electric
Quick Quote
LV433315
Schneider Electric LV433315 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range. It features a lug connection type and is designed with 3 poles. The LV433315 offers a variety of protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), phase unbalance or phase loss, locked rotor, under-load (under-current), long start, and ground fault protection (G). It has a rated current of 25A and a rated insulation voltage (Ui) of 800 V. The protection settings are adjustable, with long-time protection ranging from 0.5 to 1 x In, short-time protection from 5 to 13 x Ir, and ground fault protection from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The instantaneous protection is fixed at 425A. The LV433315 has a rated impulse voltage (Uimp) of 8 kV and a frame current rating of 100 AF. Its mechanical durability is rated at 20,000 operations at no load, and its electrical durability is rated at 10,000 operations at 690Vac; In/2 and 5,000 operations at 690Vac; In. The rated voltage (AC) phase-to-phase is 690 V, and it protects 3 poles. The trip unit type is a Micrologic 6.2E-M (LSIG) Interchangeable Electronic, which includes measurement functions for current, voltage, power, energy, demand current/power, THDu, THDv, THDi, and more. It falls under the utilisation category A.
Schneider Electric
Quick Quote
LV433314
Schneider Electric LV433314 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, designed for lug connection and equipped with four poles. It features protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), and ground fault protection (G). The rated current is 100A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable, with L ranging from 0.4 to 1 x In, S from 1.5 to 15 x Ir with a time delay of 0.1 to 0.4s, I from 1.5 to 15 x In, and G from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 100 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690V, with all four poles protected. The trip unit type is Micrologic 6.2E (LSIG) Interchangeable Electronic, featuring measurement functions such as current and voltage across phases, voltage unbalance, phase sequence, power quality indicators (P, Q, S, cos phi, Energy in kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion in current and voltage (THDu, THDv, THDi). It falls under utilisation category A.
Schneider Electric
Quick Quote
LV433312
Schneider Electric LV433312 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, featuring a 4-pole configuration with lug connection type. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), I (Instantaneous protection), and G (Ground fault protection). The rated current is 40A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable, with L ranging from 0.4 to 1 x In, S from 1.5 to 15 x Ir with a time delay of 0.1 to 0.4s, I from 1.5 to 15 x In, and G from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 40 AT. The frame current rating is 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690V, with all 4 poles protected. It features a Micrologic 6.2E (LSIG) interchangeable electronic trip unit and offers measurement functions including current, voltage, power, energy, demand current/power with an adjustable time window, and THD among others. The utilisation category is A.
Schneider Electric
Quick Quote
LV433311
Schneider Electric LV433311 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, designed for lug connection and equipped with three poles. It features protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), I (Instantaneous protection), and G (Ground fault protection). The rated current is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable, with L ranging from 0.4 to 1 x In, S from 1.5 to 15 x Ir with a time delay of 0.1 to 0.4s, I from 1.5 to 15 x In, and G from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 40 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and all three poles are protected. The trip unit type is Micrologic 6.2E (LSIG) Interchangeable Electronic, featuring measurement functions such as current and voltage across phases, unbalance percentages, phase sequence, power quality indicators (P, Q, S, cos phi, Energy in kWh, kVAh, kVARh), demand current/power with an adjustable time window, and total harmonic distortion (THDu, THDv, THDi). The utilisation category is A.
Schneider Electric
Quick Quote
LV433310
Schneider Electric LV433310 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range. It features a 4 Pole connection with lug type connectors and offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable, with L (Long-time protection) ranging from 0.4 to 1 x In, S (Short-time protection with adjustable time delay) from 1.5 to 15 x Ir with a time delay from 0.1 to 0.4s, and I (Instantaneous protection) from 1.5 to 15 x In. It has a rated impulse voltage (Uimp) of 8 kV, a trip current rating of 100 AT, and a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. The trip unit type is Micrologic 5.2E (LSI) Interchangeable Electronic, featuring measurement functions such as current and voltage across phases, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy (kWh; kVAh; kVARh), demand current/power with an adjustable time window, and total harmonic distortion (THDu, THDv, THDi). It falls under utilisation category A.
Schneider Electric
Quick Quote
LV433308
Schneider Electric LV433308 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range. It features a 4-pole connection with lug type connectors and offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current for this MCCB is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable, with L (Long-time protection) ranging from 0.4 to 1 x In, S (Short-time protection with adjustable time delay) from 1.5 to 15 x Ir with a time delay from 0.1 to 0.4s, and I (Instantaneous protection) from 1.5 to 15 x In. It has a rated impulse voltage (Uimp) of 8 kV and a trip current rating of 40 AT. The frame current rating is 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and it protects 4 poles. The trip unit type is Micrologic 5.2E (LSI) Interchangeable Electronic, featuring measurement functions such as current and voltage across phases, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy (kWh; kVAh; kVARh), demand current/power with an adjustable time window, and total harmonic distortion (THDu, THDv, THDi). It falls under the utilisation category A.
Schneider Electric
Quick Quote
LV433303
Schneider Electric LV433303 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, designed for lug connection and featuring 4 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 1500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 100 AT and a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV433302
Schneider Electric LV433302 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, designed for lug connection and featuring three poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 1500A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 100 AT and a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and it protects three poles. The trip unit type is Micrologic 2.2 (LI) Interchangeable Electronic, and it falls under utilisation category A.
Schneider Electric
Quick Quote
LV433301
Schneider Electric LV433301 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range. This 4-pole MCCB features a lug connection type and offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). It has a rated current of 40A and a rated insulation voltage (Ui) of 800 V. The protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, with I (Instantaneous protection) fixed at 600A. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 40 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability is rated at 10,000 operations at 690Vac; In/2 and 5,000 operations at 690Vac; In. The rated voltage (AC) phase-to-phase is 690 V, with all 4 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV433300
Schneider Electric LV433300 is a Moulded Case Circuit Breaker (MCCB) within the NSX100HB1 sub-range, designed for lug connection and featuring 3 poles. It offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 40A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L (Long-time protection) from 0.4 to 1 x In and S0 (Short-time protection with fixed time delay) from 1.5 to 10 x Ir, while I (Instantaneous protection) is fixed at 600A. The rated impulse voltage (Uimp) stands at 8 kV, with a trip current rating of 40 AT and a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all 3 poles protected. It features a Micrologic 2.2 (LI) interchangeable electronic trip unit and falls under utilisation category A.
Schneider Electric
Quick Quote
LV433287
Schneider Electric LV433287 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed for lug connection and equipped with three poles. It features protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), phase unbalance or phase loss, locked rotor, under-load (under-current), long start, and ground fault protection (G). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable for L, S0, and G, with specific adjustments and time delays detailed for each protection function. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 100 AT, with a frame current rating of 100 AF. Mechanical durability is noted at 20,000 operations without load, and electrical durability varies with load conditions, specified at 10,000 operations for 690Vac at half-rated current and 5,000 operations for 690Vac at rated current. The rated voltage for phase-to-phase connections is 690 V. The trip unit type is a Micrologic 6.2E-M (LSIG) Interchangeable Electronic, featuring measurement functions for current, voltage, power, energy, demand current/power, voltage unbalance, phase sequence, and total harmonic distortion among others. It is categorized under utilisation category A.
Schneider Electric
Quick Quote
LV433286
Schneider Electric LV433286 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed for lug connection and equipped with three poles. It features comprehensive protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), phase unbalance or phase loss, locked rotor, under-load (under-current), long start, and ground fault protection (G). The rated current is 50A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable, with L ranging from 0.5 to 1 x In, S0 from 5 to 13 x Ir, I fixed at 750A, and G from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. It also features a trip for >30% unbalance with a time delay of 0.7s during starting and 4s during normal operation. The rated impulse voltage (Uimp) is 8 kV, and the frame current rating is 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690V, and all three poles are protected. It utilizes a Micrologic 6.2E-M (LSIG) interchangeable electronic trip unit and offers measurement functions including current and voltage across phases, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy consumption (kWh; kVAh; kVARh), demand current/power with an adjustable time window, and total harmonic distortion (THDu, THDv, THDi). The utilisation category is A.
Schneider Electric
Quick Quote
LV433285
Schneider Electric LV433285 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range. This 3 Pole MCCB features a lug connection type and offers protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), I (Instantaneous protection), and G (Ground fault protection), along with specific protections for phase unbalance or phase loss, locked rotor, under-load (under-current), and long start. It has a rated current of 25A, with a rated insulation voltage (Ui) of 800 V. The protection settings are adjustable, with L protection ranging from 0.5 to 1 x In, S0 protection from 5 to 13 x Ir, I protection fixed at 425A, and G protection from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the frame current rating is 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and it protects 3 poles. The trip unit type is Micrologic 6.2E-M (LSIG) Interchangeable Electronic, featuring measurement functions such as current and voltage across phases, voltage unbalance, phase sequence, power metrics (P, Q, S, cos phi), energy consumption (kWh; kVAh; kVARh), demand current/power with an adjustable time window, and total harmonic distortion (THDu, THDv, THDi). The utilisation category is A.
Schneider Electric
Quick Quote
LV433284
Schneider Electric LV433284 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed for lug connection and equipped with four poles. It features protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), I (Instantaneous protection), and G (Ground fault protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable, with L (Long-time protection) ranging from 0.4 to 1 x In, S (Short-time protection with adjustable time delay) from 1.5 to 15 x Ir and a time delay of 0.1 to 0.4s, I (Instantaneous protection) from 1.5 to 15 x In, and G (Ground fault protection) from 0.2 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 100 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, and all four poles are protected. The trip unit type is Micrologic 6.2E (LSIG) Interchangeable Electronic, featuring measurement functions such as current and voltage in various forms, unbalance percentages, phase sequence, power metrics, cos phi, energy (kWh; kVAh; kVARh), demand current/power with an adjustable time window, and total harmonic distortion in current and voltage. It falls under utilisation category A.
Schneider Electric
Quick Quote
LV433282
Schneider Electric LV433282 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed for lug connection and equipped with four poles. It features protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), I (Instantaneous protection), and G (Ground fault protection). The rated current is 40A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable, with L (Long-time protection) ranging from 0.4 to 1 x In, S (Short-time protection with adjustable time delay) from 1.5 to 15 x Ir with a time delay between 0.1 to 0.4s, I (Instantaneous protection) from 1.5 to 15 x In, and G (Ground fault protection) from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 40 AT. It has a frame current rating of 100 AF, mechanical durability of 20,000 operations at no load, and electrical durability of 10,000 operations at 690Vac with half load and 5,000 operations at 690Vac with full load. The rated voltage (AC) phase-to-phase is 690V, with all four poles protected. The trip unit type is Micrologic 6.2E (LSIG) Interchangeable Electronic, featuring measurement functions for current, voltage, power quality, and energy, including I1, I2, I3, IN, Imax, Iground% unbalance%, U12, U23, U31, V1N, V2N, V3N, Uavg, Vavg, voltage unbalance, phase sequence, P, Q, S, cos phi, energy (kWh; kVAh; kVARh), demand current/power with an adjustable time window, THDu, THDv, THDi. It is categorized under Utilisation category A.
Schneider Electric
Quick Quote
LV433281
Schneider Electric LV433281 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed for lug connection and equipped with three poles. It features protection functions including long-time protection (L), short-time protection with fixed time delay (S0), instantaneous protection (I), and ground fault protection (G). The rated current is 40A, with a rated insulation voltage (Ui) of 800V. Protection settings are adjustable, with L ranging from 0.4 to 1 x In, S from 1.5 to 15 x Ir with a time delay between 0.1 to 0.4s, I from 1.5 to 15 x In, and G from 0.4 to 1 x In with a time delay of 0.1 to 0.4s. The rated impulse voltage (Uimp) is 8 kV, and the trip current rating is 40 AT, with a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690V, and all three poles are protected. The trip unit type is Micrologic 6.2E (LSIG) Interchangeable Electronic, featuring measurement functions such as current and voltage in various forms, unbalance percentages, phase sequence, power metrics, cos phi, energy (kWh; kVAh; kVARh), demand current/power with an adjustable time window, and total harmonic distortion in voltage and current (THDu, THDv, THDi). It falls under utilisation category A.
Schneider Electric
Quick Quote
LV433280
Schneider Electric LV433280 is a Moulded Case Circuit Breaker (MCCB) within the NSX100R sub-range, designed for lug connection and equipped with four poles. It features protection functions including L (Long-time protection), S0 (Short-time protection with fixed time delay), and I (Instantaneous protection). The rated current is 100A, with a rated insulation voltage (Ui) of 800 V. Protection settings are adjustable, with L (Long-time protection) ranging from 0.4 to 1 x In, S (Short-time protection with adjustable time delay) from 1.5 to 15 x Ir with a time delay from 0.1 to 0.4s, and I (Instantaneous protection) from 1.5 to 15 x In. It has a rated impulse voltage (Uimp) of 8 kV, a trip current rating of 100 AT, and a frame current rating of 100 AF. Mechanical durability is rated at 20,000 operations at no load, and electrical durability at 10,000 operations (690Vac; In/2) and 5,000 operations (690Vac; In) with load. The rated voltage (AC) phase-to-phase is 690 V, with all four poles protected. The trip unit type is Micrologic 5.2E (LSI) Interchangeable Electronic, featuring measurement functions for various electrical parameters including current, voltage, power, energy, and harmonic distortion among others. It falls under utilisation category A.
Schneider Electric
Quick Quote
Items per page:
Molded Case Circuit Breakers (MCCB)
General Guide & Overview
Understanding the dynamics of electrical safety necessitates a thorough knowledge of molded case circuit breakers, commonly known as MCCBs. They play a crucial role in the protection against electrical hazards, including fires and shocks. But, what is a molded case circuit breaker? This protective device is meticulously crafted to interrupt current flow in the event of excessive loads, ensuring the sanctity of the electrical systems it safeguards. The significance of MCCBs can't be understated, considering they follow stringent guidelines set by the National Electrical Code® (NEC®) and align with the requirements of UL 489 standards.
Diving into what is an MCCB reveals a versatile range of products. From ground fault to arc-fault circuit interrupters and from devices catered to photovoltaic systems to robust surge-protective devices, the MCCB's adaptability is as extensive as its utility. But how does a molded case circuit breaker work? Whether utilizing classic thermal magnetic trip mechanisms or sporting advanced electronic units, MCCBs are engineered to detect and respond to thermal overloads, short circuits, and ground faults with precision. Their distinct features, prescribed by UL standards, ensure that these indispensable components fulfill their protective role in diverse applications with efficacy and reliability.
Understanding Molded Case Circuit Breakers (MCCB)
Exploring the intricate realm of electrical safety, it's essential to address a common inquiry: what is the difference between MCB and MCCB circuit breakers? Minature Circuit Breakers (MCBs) are suitable for domestic applications, offering protection to individual circuits. In contrast, Molded Case Circuit Breakers (MCCBs) serve a more robust purpose in industrial environments. This distinction is pivotal in electrical engineering, impacting how we safeguard our systems from overloads and faults.
The function of an MCCB within electrical frameworks is profound. Its core responsibility lies in integrating a temperature-sensitive element with an electromagnetic component. Together, these create a robust defense mechanism against excessive current flows. Such integration is precisely executed to promptly interrupt the circuit when potential dangers like thermal overloads, short circuits, and ground faults emerge.
Evaluating MCCB vs MCB, one can recognize the vast capabilities of MCCBs to handle higher power systems and a broader range of current ratings. The MCCB's construction is a matrix of precision-engineered mechanisms designed to detect abnormal currents. A bimetallic strip within the breaker warms up under excessive current flow, bending to instigate a trip action - a fundamental aspect of what is the MCCB function.
Imagine a scenario where high currents surge through a system due to an insulation failure. Here, the MCCB's electromagnet responds instantaneously, actuating a trip and consequently mitigating the risk of damage. The difference between MCB and MCCB becomes apparent in their response to these events, emphasizing the latter's suitability for comprehensive protection in more demanding electrical infrastructures.
The evolution of MCCBs embraces the incorporation of ground fault protection directly into the trip unit, highlighting their advanced capabilities. Embracing such advancements ensures that MCCBs remain at the forefront of circuit protection technology. Fully grasping the mccb in electrical systems means recognizing its essential role in maintaining the integrity and safety of today's complex power networks.
Molded Case Circuit Breakers (MCCB) in Electrical Systems
The protection and management of electrical systems are pivotal, and when dissecting the intricacies of these systems, one frequently encounters the comparison of mcb vs mccb. The distinction between the two is substantial, with MCCBs bearing a design for higher capacity and adaptability, a clear choice for comprehensive system protection. A crucial feature, the mccb function, resides in its ability to safeguard against various fault conditions while supporting multiple applications, from residential complexes to grand scale industrial layouts. In essence, understanding what is molded case circuit breaker invites recognition of a device formed to interrupt excessive currents swiftly, thereby preserving the integrity of the electrical circuit it serves.
At the core of their operation, MCCBs are engineered to be resilient. They exhibit a multitude of trip characteristics suitable for unique environments and load profiles. Whether it be a surge within a domestic dwelling or an industrious leap in an assembly line, the MCCB interrupts these irregular currents promptly to avert probable mishaps. This dynamic performance, teamed with their adaptability, underscores the importance of mccb application in diverse electrical systems, affirming their role as indispensable components in modern power management and safety frameworks.
Advancements in technology have ensured that MCCBs are not left behind. Their proficiency now extends to safeguarding systems integrative of renewable energies, such as photovoltaic setups, and those reliant on novel power storage solutions. Given their inherent modular structure, these circuit breakers provide flexibility and reliability, reflecting their readiness to evolve in step with electrical advancements. The divergent milieu of electrical environments finds a common sentinel in MCCBs, echoing their universal presence and paramount significance in electrical safety.
FAQ
What is a Molded Case Circuit Breaker (MCCB)?
An MCCB is a type of electrical protection device that can automatically cut off electrical power when it detects an overload, short circuit, or ground fault. It's designed to protect an electrical circuit from damage caused by excess current resulting from an overload or a short circuit.
How does a Molded Case Circuit Breaker work?
An MCCB functions by combining thermal and magnetic trip elements. The thermal component, usually a bimetal strip, responds to prolonged overload conditions by bending and triggering the trip mechanism, while the magnetic element activates almost instantly in severe short-circuit conditions to protect the circuitry.
What is the difference between MCB and MCCB?
The key difference lies in their capacity and applications. MCBs, or Miniature Circuit Breakers, are designed for lower power applications and typically offer lower interrupting current ratings. MCCBs, on the other hand, are suitable for higher power applications and can handle higher current ratings, making them ideal for industrial or commercial installations.
What does MCCB stand for?
MCCB stands for Molded Case Circuit Breaker, which refers to the type of casing that encapsulates the internal components, providing a robust barrier against mechanical and environmental factors.
What is the function of an MCCB?
The primary function of an MCCB is to provide protection by interrupting the flow of electricity in the event of an overload or a fault condition, such as a short circuit or a ground fault. It safeguards electrical circuits by preventing damage to equipment and reducing the risk of electrical fires or shocks.
What are the applications of MCCBs in electrical systems?
MCCBs are versatile and are used in a variety of electrical systems ranging from residential to industrial settings. They are essential in environments where high-rated currents are used and are ideal for circuit protection in power distribution networks, such as transformer protection, backup protection, and capacitor bank protection.