AFPX-E30RD
Panasonic AFPX-E30RD is an I/O unit categorized under the expansion units sub-range, designed to function as a DC digital mixed input and output unit or cassette. It operates with a supply voltage of 24Vdc and features screw-clamp terminal connections for secure installation. This unit is suitable for DIN rail mounting, ensuring easy integration into various control systems. It is equipped with 16 digital inputs that support both sink and source types at 24Vdc, and 14 digital outputs, which are of the NO (Normally Open) contact type and can handle up to 2A.
Panasonic
Quick Quote
AFPX-E14YR
Panasonic AFPX-E14YR is an I/O unit categorized under the expansion units sub-range, designed to function as a DC digital output unit / cassette. It features screw-clamp terminal connections for secure wiring and is suitable for DIN rail mounting, facilitating easy installation in various industrial settings. This unit is equipped with 14 digital outputs, each being a normally open (NO) contact type capable of handling up to 2A, allowing for direct control of connected devices.
Panasonic
Quick Quote
AFPX-DA2
Panasonic AFPX-DA2 is an I/O unit categorized under the add-on cassettes sub-range, designed to function as an analog output (D/A converter) unit or cassette. It features screw-clamp terminal connections for secure installation and is suitable for DIN rail mounting. This unit is equipped with 2 analog outputs, supporting both 0-10Vdc and 0-20mA signals with a 1/4096 conversion resolution. It boasts a response time of 2ms across 2 channels, which are insulated, translating to a response speed of 0.002 seconds.
Panasonic
Quick Quote
AFPX-A21
Panasonic AFPX-A21 is an I/O unit categorized under the add-on cassettes sub-range, designed for analog mixed input and output functions with an A/D - D/A converter unit or cassette. It features screw-clamp terminal connections and is suitable for DIN rail mounting. This unit provides 1 x analog output with a 0-10Vdc / 0-20mA range and a 1/4096 conversion resolution. It offers a response time of 2ms for 2 channels with insulated inputs and 1ms for 1 channel with an insulated output. Additionally, it includes 2 x analog inputs supporting 0-5Vdc, 0-10Vdc, and 0-20mA ranges.
Panasonic
Quick Quote
FP0RTD6
Panasonic FP0RTD6 is an I/O unit designed for analog RTD temperature input, featuring 6 analog inputs that support 3-wire RTD sensors including Pt100, Pt1000, and Ni1000. These inputs can measure temperatures ranging from -200°C to +500°C with a resolution of 0.1°C.
Panasonic
Quick Quote
DEK1500-B1R1-V
Banner Engineering DEK1500-B1R1-V is a remote I/O controller designed for surface mounting with an ambient air temperature operation range of -20 to +60°C. It features 2 analog outputs (0-20mA / 0-10Vdc), and its degree of protection is rated at IP20 NEMA 4X. The device includes 2 digital outputs (SPDT / Form-C / NO/NC contact type; 16A / 250Vac) and 4 digital outputs (12Vdc-30Vdc; NMOS; 1A), alongside 2 digital inputs (12-30Vdc isolated inputs) and 8 digital inputs (12Vdc-30Vdc; Sink/Source/Counter) which can also function as 8AI (4-20mA / 0-10Vdc / 10kΩ thermistor). It operates as a Modbus controller within the DEK wireless kits sub-range, featuring an 8 holes (gld. and vent) PBT enclosure with a 5W solar panel and battery backup for Verizon. The supply voltage requirement is 12-30Vdc (12Vdc-24Vdc nom.), and it supports RS-485, RS-232, Modbus RTU, Modbus TCP, and Ethernet/IP communication protocols. The transmission frequency is set at 900MHz within the ISM band.
Banner
Quick Quote
DEK1500-B1R1-A
Banner Engineering DEK1500-B1R1-A is a remote I/O controller designed for surface mounting with an ambient air temperature operation range of -20 to +60°C. It features 2 analog outputs (0-20mA / 0-10Vdc), and its degree of protection is rated at IP20 NEMA 4X. The device includes 2 digital outputs (SPDT / Form-C / NO/NC contact type; 16A / 250Vac) and 4 digital outputs (12Vdc-30Vdc; NMOS; 1A), alongside 2 digital inputs (12-30Vdc isolated inputs) and 8 digital inputs (12Vdc-30Vdc; Sink/Source/Counter) which can also function as 8AI (4-20mA / 0-10Vdc / 10kΩ thermistor). It operates as a Modbus controller within the DEK wireless kits sub-range, featuring an 8-hole (gld. and vent) PBT enclosure with a 5W solar panel and battery backup for AT&T. The supply voltage requirement is 12-30Vdc (12Vdc-24Vdc nom.), and it supports RS-485, RS-232, Modbus RTU, Modbus TCP, and Ethernet/IP communication protocols. The transmission frequency is set at 900 MHz within the 900MHz ISM band.
Banner
Quick Quote
DXM700-B1R3-811389
Banner Engineering DXM700-B1R3-811389 is a remote I/O controller designed for DIN rail mounting with a polycarbonate housing. It operates within an ambient air temperature range of -20 to +60°C and offers a degree of protection rated at IP20. The dimensions of this part are H58.1mm x W70mm x D94.5mm. It features 4 digital outputs (12Vdc-30Vdc; PNP/NPN; 100mA) and operates at a transmission frequency of 2400 MHz. As a Modbus I/O controller within the DXM700-B1 series, it is equipped with a 300MHz processing speed script loaded for the CallForParts solution kit, aimed at data aggregation of sensors and wireless networks using FHSS (Frequency Hopping Spread Spectrum) technology and an M7 processor. Connection types include an RJ45 connector for Ethernet and an RP-SMA connector. The supply voltage ranges from 12-30Vdc (12Vdc-24Vdc nom.), and it supports RS-485 Modbus RTU, Modbus TCP, and Ethernet/IP communication protocols. Memory capacity includes 16MB of on-board memory and an 8GB SD card. It operates on a 2.4GHz ISM band with a 65mW radio (PE5 performance radio; worldwide) and can achieve a maximum transmission distance of 3.2km at nominal emission power.
Banner
Quick Quote
DXM1500-B2R2
Banner Engineering DXM1500-B2R2 is a remote I/O controller designed for DIN rail mounting with a polycarbonate housing. It operates within an ambient air temperature range of -20 to +60°C and offers a degree of protection rated at IP67. This controller features dimensions of H93.9mm x W156mm x D94.6mm. It is equipped with 2 analog outputs (0-20mA / 0-10Vdc), 8 digital outputs (12Vdc-30Vdc; PNP/NPN; 100mA), and digital inputs including 2 isolated inputs (12-30Vdc) and 8 inputs (12Vdc-30Vdc; Sink/Source/Counter) which can also function as 8 analog inputs (4-20mA / 0-10Vdc / 10kΩ thermistor). The DXM1500-B2R2 operates with a 300MHz processing speed suitable for high I/O count applications and includes an RJ45 connector (Ethernet) and RP-SMA connector for connectivity. It requires a supply voltage of 12-30Vdc (12Vdc-24Vdc nom.) and supports communication protocols such as RS-485, RS-232, Modbus RTU, Modbus TCP, Ethernet/IP, and PROFINET. The controller has a memory capacity of 16MB (on-board) and supports an 8GB SD card. It utilizes a 900MHz ISM band 1W radio (HE5 MultiHop data radio; North America) capable of transmitting data up to a maximum distance of 9.6km at nominal emission power.
Banner
Quick Quote
DXM1500-B2R1
Banner Engineering DXM1500-B2R1 is a remote I/O controller designed for DIN rail mounting and features a polycarbonate housing. It operates within an ambient air temperature range of -20 to +60°C and offers two analog outputs (0-20mA / 0-10Vdc), ensuring compatibility with various sensors and actuators. The device is protected to a degree of IP67, with dimensions of H93.9mm x W156mm x D94.6mm. It includes 8 digital outputs (12Vdc-30Vdc; PNP/NPN; 100mA) and 10 digital inputs, of which 2 are 12-30Vdc isolated inputs and 8 can function as either digital inputs (12Vdc-30Vdc; Sink/Source/Counter) or analog inputs (4-20mA / 0-10Vdc / 10kΩ thermistor). This Modbus I/O controller is part of the DXM1500-B2 series and is designed with a 300MHz processing speed to handle high I/O count applications efficiently. Connection options include an RJ45 connector for Ethernet and an RP-SMA connector, supporting a supply voltage range of 12-30Vdc (12Vdc-24Vdc nom.). It supports multiple communication protocols, including RS-485, RS-232, Modbus RTU, Modbus TCP, Ethernet/IP, and PROFINET. The device has a memory capacity of 16MB (on-board) and can be expanded with an 8GB SD card. It operates on a 900MHz ISM band 1W radio (PE5 performance radio; North America) with a maximum transmission distance of 9.6km at nominal emission power.
Banner
Quick Quote
DXM150-B1R3
Banner Engineering DXM150-B1R3 is a remote I/O controller designed for DIN rail mounting and features a polycarbonate housing. It operates within an ambient air temperature range of -20 to +60°C and offers a degree of protection rated at IP20. The controller dimensions are H93.9mm x W156mm x D94.6mm. It is equipped with 2 analog outputs (0-20mA / 0-10Vdc), 2 digital outputs (SPDT / Form-C / NO/NC contact type; 16A / 250Vac), and 4 digital outputs (12Vdc-30Vdc; NMOS; 1A). Additionally, it has 2 digital inputs (12-30Vdc isolated inputs) and 8 digital inputs (12Vdc-30Vdc; Sink/Source/Counter) which can also function as 8AI (4-20mA / 0-10Vdc / 10kΩ thermistor). The DXM150-B1R3, part of the DXM150-B1 series, incorporates a 100MHz processing speed suitable for high I/O count applications, isolated inputs, and a built-in relay. It utilizes Frequency Hopping Spread Spectrum (FHSS) technology with a SAM4 processor and CAN support. Connection types include an RJ45 connector for Ethernet and an RP-SMA connector. The supply voltage requirement is 12-30Vdc (12Vdc-24Vdc nom.). Communication protocols supported are RS-485, RS-232, Modbus RTU, Modbus TCP, and Ethernet/IP. Memory capacity includes 2MB of on-board memory and an 8GB SD card. Operating on a 2.4GHz ISM band with a 65mW radio (PE5 performance radio; worldwide), it achieves a maximum transmission distance of 3.2km at nominal emission power.
Banner
Quick Quote
TI41EX
Turck TI41EX is an I/O unit from the excom series designed for the connection of RTDs (resistance thermo detectors), ensuring ATEX compliance. This 4-channel analog input card features module rack plug-in connections for easy mounting. It operates within an ambient air temperature range of -20 to +60 °C and offers a degree of protection of IP20. With a net width of 18 mm, height of 118 mm, and depth of 106 mm, the TI41EX supports Ethernet/IP, Modbus TCP, PROFINET, and PROFIBUS DP communication protocols. It accommodates 4 x analog inputs for RTD types Pt100, Ni100, and Cu100.
Turck
Quick Quote
DI40EX
excom I/O System, Input Module, Digital, 4-channel, , Input module for intrinsically safe sensors, Complete galvanic isolation
Turck
Quick Quote
DI40-N
excom I/O System, Input Module, Digital, 4-channel, , Input modules for NAMUR and 3-wire sensors (NPN and PNP), Power supply of the sensors out of the module (max. 20 mA at 12 VDC), Complete galvanic isolation
Turck
Quick Quote
DI401EX
excom I/O System, Input Module, Digital, 4-channel, , Input module for intrinsically safe sensors, Complete galvanic isolation
Turck
Quick Quote
BL20-E-8DI-24VDC-P/ET
BL20 Economy Module, 8 Digital Inputs, PNP, With Extended Temperature Range, Fieldbus-independent, Electronics and connection technology in one housing, Connectivity: Push-in terminals, Protection class IP20, 8 digital inputs, 24 VDC, P switching, Extended temperature range: -25 °C…+60 °C, Circuit boards with conformal coating
Turck
Quick Quote
BL20-E-8DO-24VDC-0.5A-P/ET
BL20 Economy Module, 8 Digital Outputs, PNP, 0.5 A, With Extended Temperature Range, Fieldbus-independent, Electronics and connection technology in one housing, Connectivity: Push-in terminals, Protection class IP20, 8 digital outputs, 24 VDC, Max. 0.5 A, P switching, Extended temperature range: -25 °C…+60 °C, Circuit boards with conformal coating
Turck
Quick Quote
BL20-E-8AI-U/I-4PT/NI/ET
BL20 Economy Module, 8 Analog Inputs U/I resp. 4 PT/NI Inputs, With Extended Temperature Range, Fieldbus-independent, Electronics and connection technology in one housing, Tension spring connection, Protection class IP20, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 8 analog inputs U/I, 2-wire, Passive inputs – external power supply, 0…20mA, 4…20mA,‐10…+10VDC or 0…+10VDC, selectable per channel, resp., 4PT/NI inputs (always 2 anal
Turck
Quick Quote
BL20-E-4AO-U/I/ET
BL20 Economy Module, 4 Analog Outputs for Current/Voltage, With Extended Temperature Range, Fieldbus-independent, Electronics and connection technology in one housing, Connectivity: Push-in terminals, Protection class IP20, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 4 analog outputs, 0…20 mA, 4…20 mA,‐10…+10 VDC or 0…+10 VDC, Selectable per channel, Extended temperature range: -25 °C…+60 °C, Circuit boards with conformal coating
Turck
Quick Quote
BL20-E-16DO-24VDC-0.5A-N
BL20 Economy Module, 16 Digital Outputs, NPN, 0.5 A, , Fieldbus-independent, Electronics and connection technology in one housing, Connectivity: Push-in terminals, Protection class IP20, 16 digital outputs, 24 VDC, Max. 0.5 A, N switching
Turck
Quick Quote
Items per page:
I/O Modules
General Guide & Overview
In the world of control systems, I/O modules play a crucial role in facilitating the seamless exchange of data between the control system and external devices. These modules come in various types and offer a wide range of functionalities to meet the specific automation needs of different industries.
Before we dive into the types and options available, let's explore the fundamental functions of I/O modules. These modules serve as the intermediaries between the control system and sensors, actuators, and other peripheral devices. They ensure efficient communication, allowing the control system to receive input signals from sensors and provide output signals to actuators for precise control and automation.
Now, let's take a closer look at the different types of I/O modules. There are digital I/O modules, analog I/O modules, and specialty I/O modules. Digital I/O modules handle binary signals, such as on/off or high/low, while analog I/O modules process continuous signals like voltage or current. Specialty I/O modules are designed for specific purposes, such as temperature sensing or motor control.
When selecting an I/O module, it's important to consider the specific requirements of your control system. Factors such as the number of I/O points, communication protocols, and compatibility with the control system should all be taken into account.
With the rapid advancement of technology, I/O modules now come with a multitude of options. These options include various communication interfaces like Ethernet, USB, or serial ports, as well as additional features such as built-in diagnostics, hot-swapping capabilities, and LED indicators for easy troubleshooting.
In the next sections, we will explore the installation and management of I/O modules, as well as delve into the supported I/O modules and their features. So, keep reading to gain a comprehensive understanding of I/O modules and how they can enhance your control systems.
Installation and Management of I/O Modules
Proper setup, installation, and management of I/O modules is essential to ensure their correct functioning and compatibility with the control system. To achieve optimal performance, follow these key steps:
I/O Module Setup
1. Identify the specific I/O module required for your system based on the desired functionality.
2. Consult the manufacturer's documentation to verify compatibility with your control system and ensure that any required software or firmware updates are performed.
3. Determine the appropriate physical location for the I/O module, considering factors such as cable lengths, environmental conditions, and accessibility for maintenance and troubleshooting.
4. Connect the I/O module to the control system using the provided cables, ensuring proper alignment and secure connections.
I/O Module Installation
1. Power off the control system and any devices connected to it.
2. Insert the I/O module into the designated slot, following the manufacturer's instructions. Take note of any specific alignment or positioning requirements.
3. Secure the I/O module in place using the provided mounting brackets, ensuring a stable and vibration-free installation.
4. Power on the control system and verify that the I/O module is detected and recognized by the system.
I/O Module Management
1. Access the control system's configuration software or interface to manage and monitor the I/O module.
2. Configure the I/O module settings, such as input/output assignments, signal range, and communication protocols, according to the system requirements.
3. Regularly check the status and health of the I/O module, monitoring for any errors, malfunctions, or communication issues.
4. Perform firmware updates and maintenance tasks as recommended by the manufacturer to ensure optimal performance and reliability.
By following these installation and management guidelines, you can ensure the proper setup, installation, and ongoing functionality of your I/O modules within your control system.
Supported I/O Modules and their Features
When it comes to control systems and automation, having the right I/O modules is crucial. These modules offer a range of features and functionalities to meet specific system requirements. Let's take a closer look at some of the supported optional I/O modules and what they bring to the table.
One important aspect to consider is the I/O module's features. Different modules offer a variety of capabilities, such as analog input/output, digital input/output, temperature input, and specialty input/output. These features ensure that the I/O module can effectively communicate with and control external devices as needed, enabling seamless integration within the control system.
In addition to features, I/O modules also come with various ports for connectivity. These ports allow for easy communication and data exchange between the module and external devices. Some common ports include Ethernet ports for network connectivity, serial ports for device communication, and USB ports for easy configuration and firmware updates.
When working with I/O modules, visual feedback is essential. That's why many modules come equipped with LEDs. These LEDs provide status indicators, such as power, communication, and module health. They offer a quick and convenient way to monitor the module's operation and ensure everything is functioning as expected.
FAQ
What are I/O modules?
I/O modules are essential components in control systems that facilitate the exchange of data between the control system and external devices.
What are the major functions of an I/O module?
The major functions of an I/O module include data exchange between the control system and external devices, data buffering, data format conversion, and error detection and reporting.
What types of I/O modules are available?
There are various types of I/O modules available, including digital I/O modules, analog I/O modules, and interrupt-driven I/O modules.
How should I set up and install I/O modules?
Proper setup and installation of I/O modules are crucial for ensuring correct functioning and compatibility with the control system. It is recommended to follow the manufacturer's instructions and guidelines for installation.
How do I manage I/O modules?
I/O module management involves tasks such as configuring settings, monitoring module performance, and troubleshooting any issues that may arise.
What are some of the supported I/O modules and their features?
Supported I/O modules offer various features and functionalities to cater to specific system requirements. Some examples include modules with different types of ports such as digital and analog inputs and outputs, and modules with LED indicators for status monitoring.