Filters
Manufacturer
IO Type
Input Type
Output Type
Network Protocol
I/O Modules
part#
description
manufacturer
FDP20-16XSG
compact I/O station for PROFIBUS-DP, 16 Universal Digital Channels, , PROFIBUS-DP slave, 9-pin SUB-D socket for PROFIBUS field connection, Rotary coding switch for setting the PROFIBUS address, 3 I/O power supply groups each galvanically separated, 16 universal digital channels, DI/DO, 24 VDC, PNP, Output current: 0.5 A, Protection class IP20
Turck
Quick Quote
FEN20-16DXP
Compact IP20 Multiprotocol Ethernet I/O Station, 16 Configurable Digital PNP Channels, , EtherNet/IP™ Slave, Modbus TCP Slave, PROFINET Slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, 2 x RJ45 Sockets for Fieldbus Connection, DIN rail mount housing, 3 I/O power supply groups each galvanically separated, 16 configurable PNP channels, DI or DO, 24 VDC, Up to 1 A outputs, Protection class IP20
Turck
Quick Quote
FEN20-4DIP-4DXP
Compact IP20 Multiprotocol Ethernet I/O Station, 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels, , EtherNet/IP™ Slave, Modbus TCP Slave, PROFINET Slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, 2 x RJ45 Sockets for Fieldbus Connection, 4 digital PNP inputs, 4 configurable PNP channels, DI or DO, 24 VDC, 1 A outputs, Protection class IP20
Turck
Quick Quote
FEN20-4DIP-4DXP-DIN
Compact IP20 Multiprotocol Ethernet I/O Station, 4 Digital PNP Inputs and 4 Configurable Digital PNP Channels, , EtherNet/IP™ Slave, Modbus TCP Slave, PROFINET Slave, Integrated Ethernet Switch, 10 Mbps / 100 Mbps supported, 2 x RJ45 Sockets for Fieldbus Connection, Can be mounted on DIN rail, 4 digital PNP inputs, 4 configurable PNP channels, DI or DO, 24 VDC, 1 A outputs, Protection class IP20
Turck
Quick Quote
FGEN-IM16-4001
Compact multiprotocol I/O module for Ethernet, 16 digital pnp inputs, , Multiprotocol I/O module for the Ethernet protocols Modbus TCP, EtherNet/IP and PROFINET, PROFINET supports Fast Startup (FSU), Ethernet/IP supports QuickConnect (QC), Integrated Ethernet switch, FDT / DTM supported, Input diagnostics per port, Two inputs per port, , 7/8", 4-pin, for power supply, Power supply, galvanically separated, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module elec
Turck
Quick Quote
FGEN-IM16-5001
Compact multiprotocol I/O module for Ethernet, 16 digital pnp inputs, , Multiprotocol I/O module for the Ethernet protocols Modbus TCP, EtherNet/IP and PROFINET, PROFINET supports Fast Startup (FSU), Ethernet/IP supports QuickConnect (QC), Integrated Ethernet switch, FDT / DTM supported, Input diagnostics per port, Two inputs per port, , 7/8", 5-pin, for power supply, Power supply, galvanically separated, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module elec
Turck
Quick Quote
FGEN-IOM88-5001
Compact multiprotocol I/O module for Ethernet, 8 digital PNP inputs, 8 digital outputs 2 A, , Multiprotocol I/O module for the Ethernet protocols Modbus TCP, EtherNet/IP and PROFINET, PROFINET supports Fast Startup (FSU), Ethernet/IP supports QuickConnect (QC), Integrated Ethernet switch, FDT / DTM supported, Input diagnostics per port, Output diagnostics per channel, Two inputs or outputs per port, , 7/8", 5-pin, for power supply, Power supply, galvanically separated, Fibre-glass reinforced PA6
Turck
Quick Quote
FGEN-XSG16-4001
Compact multiprotocol I/O module for Ethernet, 16 configurable digital channels, pnp inputs / outputs 2 A, Input diagnostics per port, Output diagnostics per channel, Two freely selectable digital signals per port, , 7/8", 4-pin, for power supply, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
Turck
Quick Quote
FGEN-XSG16-5001
Compact multiprotocol I/O module for Ethernet, 16 configurable digital channels, pnp inputs / outputs 2 A, Input diagnostics per port, Output diagnostics per channel, Two freely selectable digital signals per port, , 7/8", 5-pin, for power supply, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
Turck
Quick Quote
FLDP-IM16-0001
Fieldbus I/O module PROFIBUS-DP, 16 digital pnp inputs, , Two inputs per connector, Module-related diagnostics, Fibre-glass reinforced PA6 housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connectors, Degree of protection IP67
Turck
Quick Quote
FLDP-IOM124-0001
Fieldbus I/O module PROFIBUS-DP, 12 digital pnp inputs, 4 digital outputs 2 A, , Two inputs or outputs per connector, For robot applications, Robust electromechanics, High magnetic field immunity, Intelligent terminating resistor, Module-related diagnostics, Fiber-glass reinforced housing, Vibration and shock-resistant, Encapsulated module electronics, Metal connector, Degree of protection IP67
Turck
Quick Quote
REP-DN
Accessories for Fieldbus Systems, Repeater for DeviceNet, , Robust DeviceNet™ repeater, Protection class IP67
Turck
Quick Quote
REP-DN-DROP
Turck REP-DN-DROP is a repeater designed for DeviceNet applications, functioning as a drop extender and message repeater. It features surface mounting mode and operates within an ambient air temperature range of -40 to +70°C. The unit has a net height of 220 mm, a net width of 60 mm, and a net depth of 40 mm. It is equipped with 2 x 5-pin 7/8" network connectors for both segment A (male + female) and segment B (male + female), ensuring versatile connectivity options. The repeater is protected by an IP67-rated fiberglass reinforced nylon housing with nickel-plated brass connectors, making it suitable for harsh environments. It requires a supply voltage of 11-30Vdc, with 12Vdc and 24Vdc as nominal values.
Turck
Quick Quote
TBDP-L2-16DOP
Fieldbus I/O module PROFIBUS-DP, 16 Digital PNP Outputs 2 A, , 2 x M12, 5-pin, B-coded, PROFIBUS-DP-Fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, ATEX Zone 2/22, Max. 2 A per output, Output diagnostics per channel
Turck
Quick Quote
BL67-8DI-PD
BL67 electronic module, 8 Digital Inputs, PNP, Channel Diagnostics, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 8 digital inputs, 24 VDC, PNP switching, Channel diagnostics, Wire-break monitoring, Adjustable filter times, Invertible inputs
Turck
Quick Quote
BL20-2DO-R-NC
BL20 electronic module, Relay Module, 2 Ă— Normally Closed, , Fieldbus and connection technology independent, Protection class IP20, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 2 NC channels
Turck
Quick Quote
BL67-8DI-P
BL67 electronic module, 8 Digital Inputs, PNP, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 8 digital inputs, 24 VDC, PNP switching, From version VN 01-03 and higher, the module supports accelerated start-up for applications with Fast Start-Up (FSU) and QuickConnect (QC).
Turck
Quick Quote
BL67-8DI-N
BL67 electronic module, 8 Digital Inputs, NPN, , Independent of the type of fieldbus and connection technology used, Protection class IP67, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 8 digital inputs, 24 VDC, NPN switching
Turck
Quick Quote
BL20-2DO-R-CO
BL20 electronic module, Relay Module, 2 Complementary Contacts, , Fieldbus and connection technology independent, Protection class IP20, LEDs indicate status and diagnostic, Electronics galvanically separated from the field level via optocouplers, 2 channels as changeover contacts
Turck
Quick Quote
DX80N9X6S-P6
DX80 Performance 900 MHz Node 1 W IP67; 1-Wire Serial Interface; 10-30 V dc; Female M12; Male M12 for Power
Banner
Quick Quote
Items per page:
I/O Modules
General Guide & Overview
In the world of control systems, I/O modules play a crucial role in facilitating the seamless exchange of data between the control system and external devices. These modules come in various types and offer a wide range of functionalities to meet the specific automation needs of different industries.
Before we dive into the types and options available, let's explore the fundamental functions of I/O modules. These modules serve as the intermediaries between the control system and sensors, actuators, and other peripheral devices. They ensure efficient communication, allowing the control system to receive input signals from sensors and provide output signals to actuators for precise control and automation.
Now, let's take a closer look at the different types of I/O modules. There are digital I/O modules, analog I/O modules, and specialty I/O modules. Digital I/O modules handle binary signals, such as on/off or high/low, while analog I/O modules process continuous signals like voltage or current. Specialty I/O modules are designed for specific purposes, such as temperature sensing or motor control.
When selecting an I/O module, it's important to consider the specific requirements of your control system. Factors such as the number of I/O points, communication protocols, and compatibility with the control system should all be taken into account.
With the rapid advancement of technology, I/O modules now come with a multitude of options. These options include various communication interfaces like Ethernet, USB, or serial ports, as well as additional features such as built-in diagnostics, hot-swapping capabilities, and LED indicators for easy troubleshooting.
In the next sections, we will explore the installation and management of I/O modules, as well as delve into the supported I/O modules and their features. So, keep reading to gain a comprehensive understanding of I/O modules and how they can enhance your control systems.
Installation and Management of I/O Modules
Proper setup, installation, and management of I/O modules is essential to ensure their correct functioning and compatibility with the control system. To achieve optimal performance, follow these key steps:
I/O Module Setup
1. Identify the specific I/O module required for your system based on the desired functionality.
2. Consult the manufacturer's documentation to verify compatibility with your control system and ensure that any required software or firmware updates are performed.
3. Determine the appropriate physical location for the I/O module, considering factors such as cable lengths, environmental conditions, and accessibility for maintenance and troubleshooting.
4. Connect the I/O module to the control system using the provided cables, ensuring proper alignment and secure connections.
I/O Module Installation
1. Power off the control system and any devices connected to it.
2. Insert the I/O module into the designated slot, following the manufacturer's instructions. Take note of any specific alignment or positioning requirements.
3. Secure the I/O module in place using the provided mounting brackets, ensuring a stable and vibration-free installation.
4. Power on the control system and verify that the I/O module is detected and recognized by the system.
I/O Module Management
1. Access the control system's configuration software or interface to manage and monitor the I/O module.
2. Configure the I/O module settings, such as input/output assignments, signal range, and communication protocols, according to the system requirements.
3. Regularly check the status and health of the I/O module, monitoring for any errors, malfunctions, or communication issues.
4. Perform firmware updates and maintenance tasks as recommended by the manufacturer to ensure optimal performance and reliability.
By following these installation and management guidelines, you can ensure the proper setup, installation, and ongoing functionality of your I/O modules within your control system.
Supported I/O Modules and their Features
When it comes to control systems and automation, having the right I/O modules is crucial. These modules offer a range of features and functionalities to meet specific system requirements. Let's take a closer look at some of the supported optional I/O modules and what they bring to the table.
One important aspect to consider is the I/O module's features. Different modules offer a variety of capabilities, such as analog input/output, digital input/output, temperature input, and specialty input/output. These features ensure that the I/O module can effectively communicate with and control external devices as needed, enabling seamless integration within the control system.
In addition to features, I/O modules also come with various ports for connectivity. These ports allow for easy communication and data exchange between the module and external devices. Some common ports include Ethernet ports for network connectivity, serial ports for device communication, and USB ports for easy configuration and firmware updates.
When working with I/O modules, visual feedback is essential. That's why many modules come equipped with LEDs. These LEDs provide status indicators, such as power, communication, and module health. They offer a quick and convenient way to monitor the module's operation and ensure everything is functioning as expected.
FAQ
What are I/O modules?
I/O modules are essential components in control systems that facilitate the exchange of data between the control system and external devices.
What are the major functions of an I/O module?
The major functions of an I/O module include data exchange between the control system and external devices, data buffering, data format conversion, and error detection and reporting.
What types of I/O modules are available?
There are various types of I/O modules available, including digital I/O modules, analog I/O modules, and interrupt-driven I/O modules.
How should I set up and install I/O modules?
Proper setup and installation of I/O modules are crucial for ensuring correct functioning and compatibility with the control system. It is recommended to follow the manufacturer's instructions and guidelines for installation.
How do I manage I/O modules?
I/O module management involves tasks such as configuring settings, monitoring module performance, and troubleshooting any issues that may arise.
What are some of the supported I/O modules and their features?
Supported I/O modules offer various features and functionalities to cater to specific system requirements. Some examples include modules with different types of ports such as digital and analog inputs and outputs, and modules with LED indicators for status monitoring.