Filters
Manufacturer
Electrical Safety Devices
part#
description
manufacturer
PILZ-774081
Pilz PILZ-774081 is a safety relay designed for single or dual-channel operation with capabilities for safety gate monitoring, instantaneous E-STOP monitoring, limit switch monitoring, and monitored manual reset. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The device has a net height of 87 mm, and it supports a rated current for safety output contacts of 8A at 24Vdc (DC-1), 8A at 240Vac (AC-1), 7A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirements are 195.5-264Vac (230Vac / 240Vac nominal) for AC and 20.4-26.4Vdc (24Vdc nominal) for DC. Part of the PNOZ 11 sub-range, it measures 90mm in width, has an IP40 degree of protection, and is constructed from PPO housing with an ABS front housing. The net width is 90 mm, power consumption is 9 VA, and the net depth is 121 mm. Its operating modes include options for automatic, manual, and monitored start, with the possibility to increase the number of available contacts through external modules. It features 7 x instantaneous safety outputs and 1 x instantaneous auxiliary output, plus 2 x auxiliary outputs (semiconductor outputs) and 2 x digital inputs for comprehensive safety and control.
Pilz
Quick Quote
PILZ-774066
Pilz PILZ-774066 is a safety relay designed for single or dual-channel operation with capabilities for safety gate, instantaneous E-STOP, limit switch, pressure sensitive edge, and mat monitoring. It features DIN rail mounting, operates within an ambient air temperature range of -10 to +55°C, and has a net height of 87 mm. The safety output contacts are rated at 8A for both 24Vdc (DC-1) and 240Vac (AC-1), 6A for 24Vdc (DC-13), and 5A for 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirements are 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), belonging to the PNOZ 16S sub-range. Dimensions include a width of 45mm, a degree of protection IP40, and a depth of 121 mm. The housing is made of PPO with an ABS front, and the power consumption is 3.5 VA. Operating modes include detection of earth faults, shorts across contacts, and automatic or manual start. It supports an increase in the number of available contacts through external modules. Digital outputs consist of 2 x instantaneous safety outputs and 2 x instantaneous auxiliary outputs, with protection functions that include detection of shorts across contacts. Digital inputs feature 2 x digital inputs, 1 x feedback input, and 1 x start input.
Pilz
Quick Quote
PILZ-774061
Pilz PILZ-774061 is a safety relay designed for single or dual-channel operation with capabilities for safety gate, instantaneous E-STOP, limit switch, pressure sensitive edge, and mat monitoring. It offers DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The device has a net height of 87 mm, a width of 45 mm, and a depth of 121 mm, with a degree of protection rated at IP40. It features fixed screw terminal connections and supports a supply voltage of 195.5-253Vac (230Vac nominal) or 20.4-26.4Vdc (24Vdc nominal). The safety output contacts are rated at 8A for both 24Vdc (DC-1) and 240Vac (AC-1), 6A for 24Vdc (DC-13), and 5A for 230Vac (AC-15). The housing is made of PPO with an ABS front, and the power consumption is 3.5 VA. It includes 2 x instantaneous safety outputs, 2 x digital inputs, 1 x feedback input, and 1 x start input, with protection functions against shorts across contacts and various operating modes including automatic and manual start, as well as operation with pressure sensitive mats.
Pilz
Quick Quote
PILZ-774057
Pilz PILZ-774057 is a safety relay designed for single-channel safety relay applications including safety gate monitoring, instantaneous E-STOP monitoring, and limit switch monitoring. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The device has a net height of 87 mm and supports both auto and manual start modes. It is rated for safety output contacts at 6A for 24Vdc (DC-1), 240Vac (AC-1), 24Vdc (DC-13), and 5A for 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirements are 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal) for AC and DC inputs, respectively. The PILZ-774057, part of the PNOZ X7 sub-range, measures 22.5mm in width, has an IP40 degree of protection, and is constructed from PPO housing with an ABS front housing. Its net width is 22.5 mm, and it consumes 1.5 W of power with a net depth of 121 mm. The operating mode includes single-channel operation without redundancy in the input circuit, with detection of earth faults in the start and input circuit. It offers an increase in the number of available contacts by connecting contact expansion modules or external contactors/relays. The device provides 2 x instantaneous safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load) and includes 1 x digital input (24Vdc; 50mA) and 1 x start input (Y1-Y2).
Pilz
Quick Quote
PILZ-774041
Pilz PILZ-774041 is a single-channel safety relay designed for DIN rail mounting, featuring a safe pulsing timer. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The safety output contacts are rated at 6A for both 24Vdc (DC-1) and 240Vac (AC-1), 3A for 24Vdc (DC-13), and 4A for 230Vac (AC-15). This part uses fixed screw terminal connections and belongs to the PZW sub-range. With dimensions of W45mm x D121mm and a net width of 45 mm, it offers an IP40 degree of protection. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nom.), and it is constructed with a PPO housing and an ABS front housing. The power consumption is rated at 3 W. It operates in a single-channel mode and includes digital outputs: 1 x pulsing safety outputs (1NO / SPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load; time-delay selectable between 0.05s and 3s) and 1 x pulsing safety output (2NC / 2xSPST-NC; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load; time-delay selectable between 0.05s and 3s). Additionally, it features 1 x safety input (24Vdc; 50mA) and 1 x feedback loop input (Y1-Y2), with a time delay range of 0-3s (pulsating).
Pilz
Quick Quote
PILZ-774038
Pilz PILZ-774038 is a single-channel safety relay designed for DIN rail mounting, featuring an ON-delay energization pulse timer. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The safety output contacts are rated for 6A at 24Vdc (DC-1) and 240Vac (AC-1), 3A at 24Vdc (DC-13), and 4A at 230Vac (AC-15). This model uses fixed screw terminal connections and belongs to the PZA sub-range. With dimensions of W45mm x D121mm and a net width of 45 mm, it offers an IP40 degree of protection. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), and it consumes 3W of power. The housing is made of PPO with an ABS front. Its operating mode is single-channel, featuring 1 x delayed safety output (1NO / SPST-NO each made of 2 N.O. contacts in series; with a 0-3s time-delay selectable in increments from 0.3s to 3s) and 2 x delayed auxiliary outputs (2NC / 2xSPST-NC each made of 1 N.C.; with the same time-delay options). It also includes 1 x safety input (24Vdc; 50mA) and 1 x feedback loop input (Y1-Y2).
Pilz
Quick Quote
PILZ-774035
Pilz PILZ-774035 is a safety relay designed for single-channel operation with an ON-delay energization pulse timer. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The device has a net height of 87 mm and supports a rated current for safety output contacts of 6A at 24Vdc (DC-1) and 240Vac (AC-1), 3A at 24Vdc (DC-13), and 4A at 230Vac (AC-15). It features fixed screw terminal connections and requires a supply voltage of 195.5-253Vac (230Vac nominal) within the PZA sub-range. The dimensions include a width of 45mm and a depth of 121mm, with a degree of protection rated at IP40. The housing is made of PPO with an ABS front, and the device consumes 4.5 VA of power. Operating in single-channel mode, it offers 1 x delayed safety output (1NO / SPST-NO each made of 2 N.O. contacts in series; with a 0-30s time-delay selectable between 3s and 30s) and 2 x delayed auxiliary outputs (2NC / 2xSPST-NC each made of 1 N.C.; with a 0-30s time-delay selectable between 3s and 30s). Additionally, it includes 1 x safety input (24Vdc; 50mA) and 1 x feedback loop input (Y1-Y2).
Pilz
Quick Quote
PILZ-774029
Pilz PILZ-774029 is a single-channel safety relay designed for DIN rail mounting, featuring an ON-delay energization pulse timer. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The safety output contacts are rated at 6A for both 24Vdc (DC-1) and 240Vac (AC-1), 3A for 24Vdc (DC-13), and 4A for 230Vac (AC-15). This model offers fixed screw terminal connections and belongs to the PZA sub-range. With dimensions of W45mm x D121mm and a net width of 45 mm, it provides an IP40 degree of protection. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), and it consumes 3W of power. The housing is made of PPO with an ABS front. Its operating mode is single-channel, featuring 1 x delayed safety output (1NO / SPST-NO each made of 2 N.O. contacts in series; with a 0-30s time-delay selectable in increments from 3s to 30s) and 2 x delayed auxiliary outputs (2NC / 2xSPST-NC each made of 1 N.C.; with the same time-delay options). Additionally, it includes 1 x safety input (24Vdc; 50mA) and 1 x feedback loop input (Y1-Y2).
Pilz
Quick Quote
PILZ-720300
Pilz PILZ-720300 is a connector designed for terminal connections with plug-in screw-type connections. It features a 12.5mm housing in black and has a net width of 12.5 mm. This connector is capable of accommodating 2-wires, facilitating straightforward and secure connections within automation systems.
Pilz
Quick Quote
PILZ-Z9000040
Pilz PILZ-Z9000040
Pilz
Quick Quote
PILZ-C1000058
Pilz PILZ-C1000058
Pilz
Quick Quote
PILZ-C1000061
Pilz PILZ-C1000061
Pilz
Quick Quote
PILZ-C1000038
Pilz PILZ-C1000038
Pilz
Quick Quote
PILZ-C1000030
Pilz PILZ-C1000030
Pilz
Quick Quote
PILZ-C1000025
Pilz PILZ-C1000025
Pilz
Quick Quote
PILZ-C1000023
Pilz PILZ-C1000023
Pilz
Quick Quote
PILZ-C1000022
Pilz PILZ-C1000022
Pilz
Quick Quote
PILZ-C1000018
Pilz PILZ-C1000018
Pilz
Quick Quote
PILZ-6B000005
Pilz PILZ-6B000005 is a mounting bracket designed for tilt angle and roll angle adjustment. It features a net height of 36 mm, a net width of 142 mm, and a net depth of 88 mm. This part is specifically crafted to facilitate the mounting process by allowing adjustments for optimal positioning.
Pilz
Quick Quote
PILZ-620015
Pilz PILZ-620015 is a spare part designed as a replacement incandescent bulb. It operates with a supply voltage of 24Vdc and has a power consumption of 7 W.
Pilz
Quick Quote
Items per page:
Electrical Safety Devices
General Guide & Overview
Electrical safety devices are crucial in both industrial and residential settings to protect against potential electrical hazards. Incorrect handling of electricity can lead to fires, electrocution, and serious injuries. Fortunately, there are a variety of safety devices available to prevent such dangerous situations.
So, what are electrical safety devices? These devices are specifically designed to mitigate the risks associated with electricity. They work by detecting abnormalities, interrupting the flow of electricity, or providing grounding mechanisms to ensure user safety.
In industrial settings, electrical safety devices play a vital role in preventing accidents and maintaining a secure working environment. They are used to safeguarding equipment, prevent electrical fires, and protect workers from electric shock hazards.
In residential settings, electrical safety devices are essential for creating a safe home environment. They help prevent electrical fires, minimize the risk of electrical accidents, and protect individuals from potential electrocution.
Common electrical safety devices include circuit breakers, ground fault circuit interrupters (GFCIs), surge protectors, arc fault circuit interrupters (AFCIs), and isolating transformers. Each device serves a specific purpose in protecting against different types of electrical hazards.
By understanding electrical safety devices and implementing them appropriately, industries and homes can ensure the highest level of electrical safety for their workers and inhabitants, minimizing the risk of accidents and injuries.
The Importance of Electrical Safety
Working safely with electricity is crucial to prevent accidents, injuries, and potentially disastrous consequences. It is vital for individuals to understand the various risks associated with electrical systems in order to mitigate these dangers effectively.
Electrical Safety Risks: Electricity poses several risks if not handled properly. Some common safety risks include electrical fires, electrocution, and damage to electrical devices and appliances. It is essential to take appropriate measures to minimize these risks and ensure a safe working environment.
Electrical Fires: Improper electrical installations, equipment malfunction, and overloaded circuits can lead to electrical fires. These fires can spread quickly and cause significant damage to property and even endanger lives. Understanding the causes and implementing preventative measures are essential to reduce the risk of electrical fires.
Electrical Wire Colors: Familiarity with electrical wire colors is crucial for safety. Electrical wires are color-coded to indicate their purpose and voltage. Understanding these color codes helps in proper installation, troubleshooting, and maintenance of electrical systems, reducing the risk of accidents and injuries.
Basics of Electrical Safety: Implementing basic electrical safety practices is essential for everyone, especially those working with electricity regularly. These include wearing proper personal protective equipment (PPE), ensuring proper grounding of electrical systems, using circuit breakers and fuses, and avoiding contact with live wires. Adhering to these fundamental safety measures greatly reduces the risks associated with electrical work.
The Role of Electrical PPE in Safety
Personal protective equipment (PPE) is essential for safeguarding workers against potential electrical hazards. When working with electricity, there is always a risk of arc flash and shock hazards. These PPE requirements are put in place to minimize the severity of injuries and protect individuals from life-threatening incidents.
One of the most critical aspects of electrical PPE is protecting against arc flash incidents. An arc flash can occur when there is an electrical fault or short circuit, resulting in a release of intense heat and light. Without proper protection, workers can suffer severe burns and other injuries. To mitigate these risks, electrical PPE includes flame-resistant clothing, face shields, and arc-rated gloves.
In addition to arc flash protection, electrical PPE also addresses the risk of shock hazards. Electrical shocks can cause serious injuries, including cardiac arrest and burns. To prevent such incidents, workers must wear insulated gloves, safety boots, and other appropriate gear when working with live electrical systems.
Moreover, it is crucial to ensure that workers have the necessary training and knowledge to use electrical PPE effectively. They should understand the different PPE requirements for specific tasks and be aware of the limitations and guidelines for their use. Regular inspections and maintenance of PPE are also vital to ensure their reliability and effectiveness.
FAQ
What are electrical safety devices?
Electrical safety devices are equipment or devices designed to prevent electrical hazards and protect people, property, and equipment from potential dangers associated with electricity. These devices are used in industries and homes to ensure the safe use and management of electrical systems.
Why are electrical safety devices important in industry?
Electrical safety devices are crucial in industry because they help prevent electrical accidents, fires, and injuries. They ensure the safe operation of electrical systems and protect workers, equipment, and property from the potential hazards of electricity.
What are some common electrical safety devices used in industry?
Some common electrical safety devices used in industry include circuit breakers, ground fault circuit interrupters (GFCIs), surge protectors, arc fault circuit interrupters (AFCIs), and residual current devices (RCDs). These devices help detect and prevent electrical faults, overloads, and ground faults, improving overall safety.
How do electrical safety devices work?
Electrical safety devices work by monitoring and controlling the flow of electrical current. For example, circuit breakers automatically trip and interrupt the circuit when they detect an overcurrent or overload. GFCIs detect ground faults and quickly shut off power to prevent electric shock. Surge protectors divert excess voltage to protect connected devices. AFCIs detect dangerous arcing faults and interrupt the circuit. RCDs monitor the balance of current flow and trip when they sense a ground fault.
What is the purpose of personal protective equipment (PPE) in electrical safety?
Personal protective equipment (PPE) plays a crucial role in ensuring electrical safety. It is designed to protect workers from electrical hazards, such as electric shock and arc flash. PPE includes specialized clothing, gloves, goggles, helmets, and footwear that provide insulation and resist electrical current to minimize the risk of injury.
What should be considered when using electrical PPE?
When using electrical PPE, it is important to ensure that it is the appropriate type and rating for the specific electrical hazard. PPE should be regularly inspected for damage, and workers should receive proper training on its correct usage. Additionally, it should fit properly and be comfortable to wear to ensure maximum effectiveness in protecting against electrical hazards.