Filters
Manufacturer
Current (AC-1)
Current (AC-3)
Number of Poles
UL Certification
More in this category
Contactors
part#
description
manufacturer
LC1D099M7
Schneider Electric LC1D099M7 is a magnetic contactor from the Deca sub-range, designed for fast and efficient connection with Faston spade connections. This 3-pole (3P; 3NO) contactor supports a rated current of 25A for AC-1 applications and 9A for 440Vac in AC-3 scenarios. It is suitable for DIN rail mounting and has a net width of 45 mm. The device offers a degree of protection rated at IP20 and operates within control voltage ranges of 176-242Vac at 50Hz and 187-242Vac at 60Hz, with a nominal control voltage of 220Vac. The rated operating voltage (Ue) reaches up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The LC1D099M7 can handle a rated impulse voltage (Uimp) of 6 kV and delivers rated active power outputs of 2.2kW to 5.5kW across various AC-3 voltage ranges. It also features 1 Normally Closed (NC) auxiliary contact and instantaneous auxiliary contacts type of 1NO+1NC. The rated power in horsepower (HP) varies from 0.33HP to 7.5HP across different voltages and phases, adhering to UL/CSA standards. This contactor is built to withstand 15 million operations mechanically at no load and 2 million operations electrically with load, ensuring durability. The rated voltage for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D099D7
Schneider Electric LC1D099D7 is a magnetic contactor from the Deca sub-range designed for DIN rail mounting. It features Faston spade connections and has three poles (3P; 3NO) with a rated current of 25A (AC-1) and 9A (440Vac; AC-3). The contactor offers a net width of 45 mm and is protected by an IP20 degree of protection. It operates within control voltage ranges of 33.6-46.2Vac (42Vac nominal; 50Hz; 0.8...1.1 x Uc) and 35.7-46.2Vac (42Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. This part includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it supports rated active power outputs of 2.2kW to 5.5kW across various AC voltages in AC-3 category. The rated power in horsepower (HP) ranges from 0.33HP to 7.5HP across different voltages and phases under UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability is rated at 2 million operations with load. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D099BL
Schneider Electric LC1D099BL is a magnetic contactor from the Deca sub-range designed with a low-consumption coil. It features Faston spade connections and is equipped with 3 poles (3P; 3NO), supporting a rated current of 25A (AC-1) and 9A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) of 19.2-30Vdc (24Vdc nom.; 0.8...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 2.2kW to 5.5kW across various AC-3 voltage levels. It also features 1 Normally Closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power (HP) varies from 0.33HP to 7.5HP across different voltages and phases under UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability with load is 2 million operations. The rated voltage (AC) phase-to-phase is 690 V, and it has a power consumption of 2.4 W.
Schneider Electric
Quick Quote
LC1D099B7
Schneider Electric LC1D099B7 is a magnetic contactor from the Deca sub-range designed for efficient circuit control. It features Faston spade connections and is equipped with 3 poles (3P; 3NO), supporting a rated current of 25A (AC-1) and 9A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within a control voltage range of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) and 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 2.2kW to 5.5kW across various AC voltages. It also features 1 Normally Closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power (HP) varies from 0.33HP to 7.5HP across different voltages and phases, adhering to UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability with load is 2 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D098UD
Schneider Electric LC1D098UD is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A (AC-1) and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm, and it offers a degree of protection rated at IP20. The control voltage for this unit ranges from 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both types being instantaneous. The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 15,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D098T7
Schneider Electric LC1D098T7 is a magnetic contactor from the Deca sub-range, designed with screw connections and featuring 4 poles (2NO+2NC). It has a rated current of 20A (AC-1) and is suitable for DIN rail mounting. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 384-528Vac (480Vac nominal; 50Hz; 0.8...1.1 x Uc) to 408-528Vac (480Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1D098T7 is designed for a mechanical durability of 15,000,000 operations at no load and an electrical durability of 2,000,000 operations with load. The rated impulse voltage (Uimp) is 6 kV, and the rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D098R7
Schneider Electric LC1D098R7 is a magnetic contactor from the Deca sub-range, featuring screw connections and a 4-pole (2NO+2NC) configuration. It has a rated current of 20A (AC-1) and is designed for DIN rail mounting. The net width of the contactor is 45 mm, and it offers a degree of protection of IP20. The control voltage (AC) ranges from 352-484Vac at 50Hz and 374-484Vac at 60Hz, with a nominal voltage of 440Vac. The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type. The rated impulse voltage (Uimp) is 6 kV, and the mechanical durability at no load is rated for 15,000,000 operations. The rated voltage (AC) for phase-to-phase connections is also 690 V.
Schneider Electric
Quick Quote
LC1D098Q7
Schneider Electric LC1D098Q7 is a magnetic contactor within the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A (AC-1) and is suitable for DIN rail mounting. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 304-418Vac at 50Hz and 323-418Vac at 60Hz, with a nominal voltage of 380Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both types being instantaneous. The rated impulse voltage (Uimp) is 6 kV. This contactor is designed for mechanical durability of up to 15,000,000 operations at no load, and the rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D098JD
Schneider Electric LC1D098JD is a magnetic contactor within the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A under AC-1 conditions and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm, and it offers a degree of protection rated at IP20. This contactor operates with a control voltage (DC) range of 9-15Vdc, with a nominal value of 12Vdc, and can handle a rated operating voltage (Ue) up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both rated for instantaneous operation. The contacts type is specified as 1NO+1NC instantaneous aux. It boasts a mechanical durability of 15,000,000 operations at no load and can withstand a rated impulse voltage (Uimp) of 6 kV. The rated voltage for phase-to-phase connections is specified at 690 V.
Schneider Electric
Quick Quote
LC1D098GD
Schneider Electric LC1D098GD is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A under AC-1 conditions and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm, and it offers a degree of protection rated at IP20. This contactor operates with a control voltage range of 94-156Vdc, nominally set at 125Vdc, allowing for a variation between 0.75 to 1.25 times the control voltage (Uc). It is capable of handling a rated operating voltage (Ue) up to 690 V and has a rated impulse voltage (Uimp) of 6 kV. The LC1D098GD includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). It boasts a mechanical durability of 15 million operations at no load and is designed to work with a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote
LC1D098EL
Schneider Electric LC1D098EL is a magnetic contactor from the Deca sub-range, designed with a low-consumption coil. This contactor features screw connections and is equipped with 4 poles (2NO+2NC), supporting a rated current of 20A under AC-1 conditions. It is suitable for DIN rail mounting and has a net width of 45 mm. The LC1D098EL offers a degree of protection rated at IP20 and operates with a control voltage range of 38.4-60Vdc, with a nominal value of 48Vdc (0.8...1.25 x Uc). Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contact, both of the instantaneous type. The contactor is designed to withstand a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 15,000,000 operations at no load. The power consumption of the coil is 2.4 W, and it is capable of handling phase-to-phase rated voltages up to 690 V.
Schneider Electric
Quick Quote
LC1D098D7
Schneider Electric LC1D098D7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A under AC-1 conditions and is suitable for DIN rail mounting. The contactor's net width is 45 mm and it offers a degree of protection rated at IP20. The control voltage for AC ranges between 33.6-46.2Vac at 50Hz (42Vac nominal) with a factor of 0.8...1.1 times Uc, and 35.7-46.2Vac at 60Hz (42Vac nominal) with a factor of 0.85...1.1 times Uc. It is capable of operating at a rated voltage (Ue) of up to 690 V and includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and it boasts a mechanical durability of 15,000,000 operations at no load. The rated voltage for AC phase-to-phase is also 690 V.
Schneider Electric
Quick Quote
LC1D0983ED
Schneider Electric LC1D0983ED is a magnetic contactor from the Deca sub-range, featuring spring connections and a 4-pole (2NO+2NC) configuration. It has a rated current of 20A (AC-1), designed for DIN rail mounting, and measures 45 mm in width. This contactor offers a degree of protection of IP20 and operates with a control voltage of 36-60Vdc (48Vdc nominal; 0.75...1.25 x Uc). The rated operating voltage (Ue) is 690 V, with 1 NO and 1 NC auxiliary contacts, and a contacts type of 1NO+1NC instantaneous aux. It has a rated impulse voltage (Uimp) of 6 kV, mechanical durability of 15,000,000 operations at no load, and electrical durability of 2,000,000 operations with load. The rated voltage (AC) for phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D096R7
Schneider Electric LC1D096R7 is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. It features 3 poles (3P; 3NO) and is rated for currents of 25A (AC-1) and 9A (440Vac; AC-3). This contactor can be mounted on a DIN rail and has a net width of 45 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 352-484Vac (440Vac nominal; 50Hz; 0.8...1.1 x Uc) and 374-484Vac (440Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it has a rated active power of up to 5.5kW across various AC-3 voltage ratings. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power (HP) varies from 0.33HP at 115Vac to 7.5HP at 575-600Vac, under UL/CSA standards for single-phase and 3-phase connections. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability is rated at 2 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D096Q7
Schneider Electric LC1D096Q7 is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. It features 3 poles (3P; 3NO) and is rated for currents of 25A (AC-1) and 9A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 304-418Vac (380Vac nominal; 50Hz; 0.8...1.1 x Uc) and 323-418Vac (380Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 2.2kW at 220-230Vac to 5.5kW at 660-690Vac (AC-3), and it also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 0.33HP at 115Vac to 7.5HP at 575-600Vac, under UL/CSA standards for both single-phase and 3-phase connections. It boasts a mechanical durability of 15 million operations at no load and an electrical durability of 2 million operations with load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric
Quick Quote
LC1D096N7
Schneider Electric LC1D096N7 is a magnetic contactor from the Deca sub-range, featuring ring-lugs connections and designed with 3 poles (3P; 3NO). It has a rated current of 25A (AC-1) and 9A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) to 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 2.2kW at 220-230Vac to 5.5kW at 660-690Vac (all AC-3). The rated power (HP) varies from 0.33HP at 115Vac to 7.5HP at 575-600Vac, under UL/CSA standards for both single-phase and 3-phase connections. This contactor is built to achieve mechanical durability of 15,000,000 operations and electrical durability of 2,000,000 operations with load, supporting a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote
LC1D096GD
Schneider Electric LC1D096GD is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. It features 3 poles (3P; 3NO) and is rated for a current of 25A (AC-1) and 9A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) of 94-156Vdc (125Vdc nom.; 0.75...1.25 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power is 2.2kW (220-230Vac; AC-3), 4kW (380-400Vac; AC-3), 4kW (415Vac; AC-3), 4kW (440Vac; AC-3), 5.5kW (500Vac; AC-3), and 5.5kW (660-690Vac; AC-3). It also features 1 normally closed (NC) auxiliary contact and contacts type of 1NO+1NC instantaneous aux. The rated power (HP) includes 0.33HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 1HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 2HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 2HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 5HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 7.5HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). It has a mechanical durability of 15,000,000 operations and an electrical durability of 2,000,000 operations with load. The rated voltage (AC) - phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D096EL
Schneider Electric LC1D096EL is a magnetic contactor from the Deca sub-range, featuring a low-consumption coil design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 25A for AC-1 and 9A for 440Vac in AC-3 conditions. It is designed for DIN rail mounting and has a net width of 45 mm. The LC1D096EL offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 38.4-60Vdc, nominally at 48Vdc. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 2.2kW at 220-230Vac to 5.5kW at 660-690Vac in AC-3 conditions. Additionally, it features 1 normally closed (NC) auxiliary contact and instantaneous auxiliary contacts type of 1NO+1NC. The rated power in horsepower (HP) varies from 0.33HP at 115Vac in single-phase to 7.5HP at 575-600Vac in 3-phase conditions, according to UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability with load is 2 million operations. The rated voltage (AC) phase-to-phase is 690 V, and it has a power consumption of 2.4 W.
Schneider Electric
Quick Quote
LC1D096E7
Schneider Electric LC1D096E7 is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. It features 3 poles (3P; 3NO) and is rated for currents of 25A (AC-1) and 9A (440Vac; AC-3). This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates within control voltage ranges of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 2.2kW at 220-230Vac to 5.5kW at 660-690Vac (AC-3). It also features 1 normally closed (NC) auxiliary contact and instantaneous auxiliary contacts type of 1NO+1NC. The rated power in horsepower (HP) ranges from 0.33HP at 115Vac to 7.5HP at 575-600Vac, under various conditions as specified. The mechanical durability of the LC1D096E7 is rated at 15 million operations at no load, and its electrical durability with load is 2 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D093R7
Schneider Electric LC1D093R7 is a magnetic contactor from the Deca sub-range, featuring spring connections and designed with 3 poles (3P; 3NO). It has a rated current of 16A (AC-1) and 9A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 352-484Vac (440Vac nom.; 50Hz; 0.8...1.1 x Uc) to 374-484Vac (440Vac nom.; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Rated active power spans from 2.2kW (220-230Vac; AC-3) to 5.5kW (660-690Vac; AC-3), and the rated power (HP) ranges from 0.33HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 7.5HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). Mechanical durability is specified at 15 million operations at no load, and electrical durability at 2 million operations with load. The rated voltage (AC) for phase-to-phase is 690 V.
Schneider Electric
Quick Quote