Filters
Manufacturer
Current (AC-1)
Current (AC-3)
Number of Poles
UL Certification
More in this category
Contactors
part#
description
manufacturer
LC1D50BW
Schneider Electric LC1D50BW is a magnetic contactor from the Deca sub-range, designed with a wide-range coil (0.75-1.2 x Uc) for flexibility in control voltage, which ranges from 18-28.8Vdc (24Vdc nom.; 0.75...1.2 x Uc). It features screw connections for secure installation and is equipped with three poles (3P; 3NO) for comprehensive circuit control. The contactor is rated for currents up to 80A (AC-1) and 50A (440Vac; AC-3), and it can be mounted on a DIN rail, offering an IP20 degree of protection. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It supports rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D50BW is rated at 15 million operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50AYC7
Schneider Electric LC1D50AYC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 528-726Vac at 50Hz and 561-726Vac at 60Hz, with a nominal voltage of 660Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D50AYC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.45 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50AY7
Schneider Electric LC1D50AY7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and screw connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 552-759Vac (690Vac nominal; 50Hz; 0.8...1.1 x Uc) and 586.5-759Vac (690Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It supports rated active power (kW) of 15kW at 220-230Vac, 22kW at 380-400Vac, 25kW at 415Vac, 30kW at 440Vac and 500Vac, and 33kW at 660-690Vac, all under AC-3 category. The rated power (HP) under UL/CSA standards includes 3HP at 115Vac single-phase, 7.5HP at 230-240Vac single-phase, 15HP at 200-208Vac and 230-240Vac 3-phase, and 40HP at 460-480Vac and 575-600Vac 3-phase. It has a mechanical durability of 6,000,000 operations and an electrical durability of 1,450,000 operations with load. The rated current is 80A for AC-1 and 50A for 440Vac AC-3, with a phase-to-phase rated voltage (AC) of 690 V.
Schneider Electric
Quick Quote
LC1D50AUD
Schneider Electric LC1D50AUD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 187.5-312.5Vdc (250Vdc nom.; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW (220-230Vac; AC-3) to 33kW (660-690Vac; AC-3), and its rated power (HP) ranges from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 40HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability at no load is 6,000,000 operations, and the electrical durability with load is 1,450,000 operations. The rated voltage (AC) - phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50ASC7
Schneider Electric LC1D50ASC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 50A for AC-3 at 440Vac. It is designed for DIN rail mounting with a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 460-632Vac with a nominal frequency of 50Hz and 60Hz, respectively. The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D50ASC7 is rated at 6 million operations, and its electrical durability with load is 1.45 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50AS7
Schneider Electric LC1D50AS7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 400-550Vac at 50Hz and 425-550Vac at 60Hz, with a nominal voltage of 500Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3, and the rated power in horsepower (HP) ranges from 3HP at 115Vac to 40HP at 575-600Vac, covering various configurations under UL/CSA standards for both single-phase and 3-phase systems. The mechanical durability of the LC1D50AS7 is rated at 6 million operations, and its electrical durability with load is 1.45 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50AND
Schneider Electric LC1D50AND is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 45-75Vdc, with a nominal value of 60Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3, and it has both 1NO+1NC instantaneous auxiliary contacts. The rated power in horsepower (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, suitable for both single-phase and 3-phase systems. It boasts a mechanical durability of 6 million operations and an electrical durability of 1.45 million operations with load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric
Quick Quote
LC1D50AED
Schneider Electric LC1D50AED is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 36-60Vdc, with a nominal 48Vdc, and it operates at a rated voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power reaches up to 33kW for 660-690Vac in AC-3, and the rated power (HP) spans from 3HP at 115Vac to 40HP at 575-600Vac, covering various configurations for both single-phase and three-phase systems. The mechanical durability is rated at 6,000,000 operations, and the electrical durability, with load, is 1,450,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50AC7
Schneider Electric LC1D50AC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and screw connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 25.6-35.2Vac (32Vac nominal; 50Hz; 0.8...1.1 x Uc) and 27.2-35.2Vac (32Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 80A (AC-1) and 50A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power outputs of 15kW (220-230Vac; AC-3) up to 33kW (660-690Vac; AC-3) and rated power (HP) for motors ranging from 3HP (115Vac; single-phase) to 40HP (575-600Vac; 3-phase). The mechanical durability is rated at 6,000,000 operations, and electrical durability (with load) at 1,450,000 operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
LC1D50A6V7
Schneider Electric LC1D50A6V7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 320-440Vac (400Vac nominal; 50Hz; 0.8...1.1 x Uc) and 340-440Vac (400Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3 applications. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase applications to 40HP at 575-600Vac in three-phase applications, according to UL/CSA standards. It boasts a mechanical durability of 6,000,000 operations and an electrical durability of 1,450,000 operations with load. The rated voltage (AC) for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D50A6Y7
Schneider Electric LC1D50A6Y7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 50A for AC-3 at 440Vac. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 552-759Vac at 50Hz and 586.5-759Vac at 60Hz, with a nominal voltage of 690Vac. The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power in kW varies with voltage, offering 15kW at 220-230Vac, up to 33kW at 660-690Vac in AC-3. The rated power in HP for UL/CSA standards ranges from 3HP at 115Vac to 40HP at 575-600Vac. The mechanical durability of the contactor is 6,000,000 operations, and its electrical durability with load is 1,450,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A6UD
Schneider Electric LC1D50A6UD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A6UD offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor is capable of handling rated active power ranging from 15kW at 220-230Vac AC-3 to 33kW at 660-690Vac AC-3. It also features 1 normally closed (NC) auxiliary contact with 1NO+1NC instantaneous auxiliary contacts type. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase applications, according to UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,450,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A6U7
Schneider Electric LC1D50A6U7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) range of 192-264Vac (240Vac nominal; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 80A (AC-1) and 50A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power outputs of 15kW (220-230Vac; AC-3) up to 33kW (660-690Vac; AC-3) and rated power (HP) ranging from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 40HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability is rated at 6,000,000 operations, and electrical durability (with load) at 1,450,000 operations. The rated voltage (AC) for phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A6T7
Schneider Electric LC1D50A6T7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting with a net width of 55 mm and offers an IP20 degree of protection. The control voltage ranges from 384-528Vac at 50Hz and 408-528Vac at 60Hz, with a nominal control voltage of 480Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It delivers rated active power up to 33kW for AC-3 applications across various voltages and rated power in horsepower (HP) for UL/CSA standards, including 3HP at 115Vac single-phase and up to 40HP at 575-600Vac 3-phase. The mechanical durability is rated at 6 million operations, and electrical durability with load at 1.45 million operations. The rated voltage for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D50A6S7
Schneider Electric LC1D50A6S7 is a magnetic contactor from the Deca sub-range featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A6S7 offers a degree of protection of IP20 and operates with a control voltage range of 400-550Vac at 50Hz and 425-550Vac at 60Hz. Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power outputs of 15kW to 33kW across various AC-3 voltage ranges and rated power in horsepower from 3HP to 40HP under UL/CSA standards for single-phase and three-phase applications. It boasts a mechanical durability of 6 million operations and an electrical durability of 1.45 million operations at load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric
Quick Quote
LC1D50A6Q7
Schneider Electric LC1D50A6Q7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 50A for 440Vac in AC-3 conditions. It is designed for DIN rail mounting and has a net width of 55 mm. The degree of protection provided is IP20. The control voltage (AC) ranges from 304-418Vac at 50Hz and 323-418Vac at 60Hz, with a nominal voltage of 380Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It supports rated active power up to 33kW for 660-690Vac in AC-3 conditions. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability is rated at 6,000,000 operations, and electrical durability at 1,450,000 operations with load. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric
Quick Quote
LC1D50A6ND
Schneider Electric LC1D50A6ND is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 and 50A for 440Vac in AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A6ND offers a degree of protection of IP20 and operates with a control voltage (DC) range of 45-75Vdc, nominally at 60Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. It is capable of controlling rated active power up to 33kW for 660-690Vac in AC-3 conditions. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase applications, according to UL/CSA standards. The mechanical durability of the LC1D50A6ND is rated at 6 million operations at no load, and its electrical durability is rated at 1.45 million operations with load. The rated voltage for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D50A6N7
Schneider Electric LC1D50A6N7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, with a contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV. Rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3 applications. Rated power in horsepower (HP) ranges from 3HP at 115Vac to 40HP at 575-600Vac, covering both single-phase and 3-phase applications under UL/CSA standards. The mechanical durability of the contactor is rated at 6,000,000 operations, and its electrical durability with load is 1,450,000 operations. The rated voltage (AC) for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D50A6MD
Schneider Electric LC1D50A6MD is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design for ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting with a net width of 55 mm and offers an IP20 degree of protection. The control voltage (DC) ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3 applications. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase applications, according to UL/CSA standards. The mechanical durability of the LC1D50A6MD is rated at 6 million operations, and its electrical durability with load is 1.45 million operations. The rated voltage (AC) for phase-to-phase applications is 690 V.
Schneider Electric
Quick Quote
LC1D50A6L7
Schneider Electric LC1D50A6L7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 160-220Vac at 50Hz and 170-220Vac at 60Hz, with a nominal voltage of 200Vac. It operates at a rated operating voltage (Ue) of 690 V and includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D50A6L7 is rated at 6 million operations, and its electrical durability with load is 1.45 million operations. The rated voltage (AC) for phase-to-phase connections is 690 V.
Schneider Electric
Quick Quote
Items per page: