Filters
Manufacturer
More in this category
Compressed Air Preparation Units
part#
description
manufacturer
GPFR200N08ALJMT
AirTAC GPFR200N08ALJMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, Nylon bowl, 1/4"NPT, 0.3 micron., Auto Drain N.O., With Gauge, Without bracket
AirTAC
Quick Quote
GPFR200N08ALJNMT
AirTAC GPFR200N08ALJNMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, Nylon bowl, 1/4"NPT, 0.3 micron., Auto Drain N.O., Without Gauge, Without bracket
AirTAC
Quick Quote
GPFR200N08LNDT
AirTAC GPFR200N08LNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, Nylon bowl, 1/4"NPT, 0.01 micron, Semi-auto Drain, Without Gauge, With bracket
AirTAC
Quick Quote
GPFR200N08LMT
AirTAC GPFR200N08LMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, Nylon bowl, 1/4"NPT, 0.3 micron., Semi-auto Drain, With Gauge, With bracket
AirTAC
Quick Quote
GPFR30008ALJNDT
AirTAC GPFR30008ALJNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, PC bowl, 1/4"NPT, 0.01 micron, Auto Drain N.O., Without Gauge, Without bracket
AirTAC
Quick Quote
GPFR30008ALMT
AirTAC GPFR30008ALMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, PC bowl, 1/4"NPT, 0.3 micron., Auto Drain N.O., With Gauge, With bracket
AirTAC
Quick Quote
GPFR30008ASJDT
AirTAC GPFR30008ASJDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 0.01 micron, Auto Drain N.O., With Gauge, Without bracket
AirTAC
Quick Quote
GPFR30008ASJMT
AirTAC GPFR30008ASJMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 0.3 micron., Auto Drain N.O., With Gauge, Without bracket
AirTAC
Quick Quote
GPFR30008ASMT
AirTAC GPFR30008ASMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 0.3 micron., Auto Drain N.O., With Gauge, With bracket
AirTAC
Quick Quote
GPFR30008ASNDT
AirTAC GPFR30008ASNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 0.01 micron, Auto Drain N.O., Without Gauge, With bracket
AirTAC
Quick Quote
GPFR30008ASNMT
AirTAC GPFR30008ASNMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 0.3 micron., Auto Drain N.O., Without Gauge, With bracket
AirTAC
Quick Quote
GPFR30008SJNMT
AirTAC GPFR30008SJNMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/4"NPT, 0.3 micron., Semi-auto Drain, Without Gauge, Without bracket
AirTAC
Quick Quote
GPFR30010ASNDT
AirTAC GPFR30010ASNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 3/8"NPT, 0.01 micron, Auto Drain N.O., Without Gauge, With bracket
AirTAC
Quick Quote
GPFR40010ASJNDT
AirTAC GPFR40010ASJNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 3/8"NPT, 0.01 micron, Auto Drain N.O., Without Gauge, Without bracket
AirTAC
Quick Quote
GPFR40010LJMT
AirTAC GPFR40010LJMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, PC bowl, 3/8"NPT, 0.3 micron., Semi-auto Drain, With Gauge, Without bracket
AirTAC
Quick Quote
GPFR40010LJNDT
AirTAC GPFR40010LJNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, PC bowl, 3/8"NPT, 0.01 micron, Semi-auto Drain, Without Gauge, Without bracket
AirTAC
Quick Quote
GPFR40010LNDT
AirTAC GPFR40010LNDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, PC bowl, 3/8"NPT, 0.01 micron, Semi-auto Drain, Without Gauge, With bracket
AirTAC
Quick Quote
GPFR40010SNMT
AirTAC GPFR40010SNMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 3/8"NPT, 0.3 micron., Semi-auto Drain, Without Gauge, With bracket
AirTAC
Quick Quote
GPFR40015ALJNMT
AirTAC GPFR40015ALJNMT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 7psi~58psi, PC bowl, 1/2"NPT, 0.3 micron., Auto Drain N.O., Without Gauge, Without bracket
AirTAC
Quick Quote
GPFR40015ASDT
AirTAC GPFR40015ASDT - GPFR Series Coalescing Filter&Regulator, Adjustable pressure 20psi~130psi, PC bowl, 1/2"NPT, 0.01 micron, Auto Drain N.O., With Gauge, With bracket
AirTAC
Quick Quote
Items per page:
Compressed Air Preparation Units
General Guide & Overview
Compressed air is a widely used form of energy in various industries, powering pneumatic systems and equipment. However, the air leaving the compressor is often not suitable for direct use due to impurities and incorrect pressure levels. That's where air preparation units, also known as FRL units (Filter, Regulator, Lubricator), play a crucial role.
Air preparation units are designed to condition the compressed air, ensuring optimal performance and efficiency. The FRL unit consists of three separate units that carry out different phases of conditioning: filtration, regulation, and lubrication.
Filtration is the first step, where contaminants such as dust, water, and oil are removed from the compressed air. This ensures that downstream equipment remains protected and operates at its best. Regulation is the second phase, controlling the pressure of the compressed air in the system to match the requirements of the application. Lastly, lubrication introduces controlled amounts of oil into the flow of compressed air, reducing friction and increasing the lifespan of air-driven equipment.
Proper selection of the filter size, pressure rating, port size, and lubricator type is essential to meet the specific requirements of each application. By investing in high-quality compressed air preparation units, you can ensure the longevity of your pneumatic equipment and optimize its performance.
So, whether you are in manufacturing, automotive, or any other industry that relies on compressed air, understanding the importance of air preparation units is vital for efficient and reliable operation.
Importance of Air Preparation in Pneumatic Systems
Air preparation plays a vital role in pneumatic systems, ensuring the cleanliness, pressure, and lubrication of compressed air. In order to maintain optimal performance and reliability, it is crucial to address the presence of contaminants such as particles, water, and oil that can impair the operation of pneumatic components. Proper filtration is necessary to remove dirt, dust, and other particles from the compressed air and minimize the risk of damage to downstream equipment.
Moisture and oil, which can negatively impact the performance of pneumatic systems, are effectively eliminated through the use of coalescing filters. The level of air purity required will vary depending on the specific application, and different industry segments may have additional requirements to ensure the proper functioning of their equipment. Therefore, it is essential to select and implement the appropriate air preparation measures.
In addition to addressing contaminants, the flow rate of compressed air must be adequate to achieve the desired cylinder piston travel speeds. Furthermore, the operating pressure of the system needs to be carefully matched to the requirements of the application for optimal performance. By paying attention to these factors and implementing proper air preparation techniques, businesses can improve the process reliability, machine availability, and service life of their pneumatic components.
Tips for Designing and Specifying Air Preparation Systems
When designing or specifying air preparation subsystems, engineers need to consider several key factors to ensure optimal performance and minimize maintenance costs. One crucial aspect is properly matching the port sizes and operating pressure ranges of pneumatic components. This ensures efficient operation and prevents issues such as pressure drops or excessive pressure that can lead to equipment damage or downtime.
Another important consideration is the inclusion of disconnect components, such as manual shut-off relief valves and isolation/lockout valves. These components provide a means to isolate downstream equipment from the compressed air source, allowing for safe maintenance procedures and preventing inadvertent re-energization. This not only enhances safety but also reduces the risk of equipment breakdown and associated maintenance costs.
Air filtration is a critical aspect of air preparation systems, as it eliminates contaminants that could affect the performance and lifespan of pneumatic equipment. Various passive filters, such as centrifugal and coalescing filters, effectively remove particles, water, and oil from the compressed air, ensuring clean and reliable operation. Additionally, implementing appropriate drain systems, such as manual, semi-automatic, or automatic drains, helps to remove accumulated moisture from the filter bowl, further enhancing the efficiency and longevity of the system.
Finally, maintaining proper downstream air pressure is of utmost importance. This can be achieved through the installation of air pressure regulators. These regulators ensure that the compressed air delivered to the equipment operates at the correct pressure, preventing potential damage or inefficiencies caused by excessive or insufficient pressure. By following these tips and incorporating the right components, engineers can design and specify air preparation systems that optimize the performance and longevity of pneumatic equipment, ultimately reducing maintenance costs and downtime.
FAQ
What is an air preparation unit?
An air preparation unit, also known as an FRL unit (Filter, Regulator, Lubricator), is used to condition compressed air by removing contaminants, regulating pressure, and introducing controlled amounts of oil for lubrication.
Why is air preparation important in pneumatic systems?
Air preparation is essential in pneumatic systems to ensure the correct air cleanliness, pressure, and lubrication. Contaminants can impair the operation of components and reduce system reliability.
What does filtration do in an air preparation unit?
Filtration in an air preparation unit removes contaminants such as dust, water, and oil from the compressed air, ensuring cleaner air for downstream equipment.
How does regulation work in an air preparation unit?
Regulation in an air preparation unit controls the pressure of the compressed air in the system, allowing for precise pressure adjustments based on the requirements of the application.
Why is lubrication necessary in an air preparation unit?
Lubrication in an air preparation unit introduces controlled amounts of oil into the compressed air flow, reducing friction and increasing the lifespan of air-driven equipment.
What factors should I consider when designing or specifying air preparation subsystems?
When designing or specifying air preparation subsystems, consider proper port sizes and operating pressure ranges, disconnect components for isolation and lockout, air filtration for removing contaminants, drain systems for moisture removal, and air pressure regulators for maintaining proper downstream pressure.