LC1D95F7 Schneider Electric Automation components
Part#:LC1D95F7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 3
May 20, 2024
About the product: Schneider Electric - LC1D95F7
About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D95F7 Schneider Electric price in the box on the right side or send a quick quote.
LC1D95F7 Product Details
- Product Certifications IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL
- [Icw] Rated Short-Time Withstand Current 1100 A 104 °F (40 °C) - 1 s power circuit 800 A 104 °F (40 °C) - 10 s power circuit 400 A 104 °F (40 °C) - 1 min power circuit 135 A 104 °F (40 °C) - 10 min power circuit 140 A - 100 ms signalling circuit 120 A - 500 ms signalling
- Motor Power Kw 25 kW 220...230 V AC 50 Hz AC-3) 45 kW 380...400 V AC 50 Hz AC-3) 45 kW 415...440 V AC 50 Hz AC-3) 55 kW 500 V AC 50 Hz AC-3) 45 kW 660...690 V AC 50 Hz AC-3) 45 kW 1000 V AC 50 Hz AC-3)
- Motor Power HP (UL / CSA) 7.5 hp 115 V at AC 60 Hz for 1 phase 15 hp 230/240 V at AC 60 Hz for 1 phase 25 hp 200/208 V at AC 60 Hz for 3 phase 30 hp 230/240 V at AC 60 Hz for 3 phase 60 hp 460/480 V at AC 60 Hz for 3 phase 60 hp 575/600 V at AC 60 Hz for 3
- Standards EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
- [Ui] Rated Insulation Voltage Power circuit 1000 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Control Circuit Voltage Limits 0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
- Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.21 lbf.in
- Irms Rated Making Capacity 1100 A 440 V AC power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flex
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit
- Utilisation Category AC-3 AC-1 AC-4
- Hold-In Power Consumption In VA 26 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C))
- Contactor Application Motor control Resistive load
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 125 A 140 °F (60 °C) power circuit
- Mounting Support Rail Plate
- Operating Time 20...35 ms closing 6...20 ms opening
- Electrical Durability 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Safety Reliability Level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Power Dissipation Per Pole 12.5 W AC-1 7.2 W AC-3
- [Ie] Rated Operational Current 95 A 140 °F (60 °C)) <= 440 V AC-3 power circuit 125 A 140 °F (60 °C)) <= 690 V AC-1 power circuit
- Inrush Power In VA 245 VA 60 Hz 0.75 68 °F (20 °C)) 245 VA 50 Hz 0.75 68 °F (20 °C))
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Mechanical Durability 4 Mcycles
- Heat Dissipation 6…10 W 50/60 Hz
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Coil Technology Without built-in suppressor module
- Front Cover With
- Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
- Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
- Overvoltage Category III
- Auxiliary Contact Composition 1 NO + 1 NC
- Poles Description 3P
- Control Circuit Type AC 50/60 Hz
- [Uc] Control Circuit Voltage 110 V AC 50/60 Hz
- Product Or Component Type Contactor
- [Ue] Rated Operational Voltage Power circuit 1000 V AC 25...400 Hz
- Device Short Name LC1D
- Product Name TeSys D
- Range TeSys
- Power Pole Contact Composition 3 NO
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Related documents LC1D95F7 Specs
This item can ship within 3 days!
1-year warranty
$636.46
LC1D95F7
Stock:
3
Select Qty:
$636.46
$636.46 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨