LC1D65AU7 Schneider Electric Automation Components
Part#:LC1D65AU7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 1
Apr 27, 2024
About the product: Schneider Electric - LC1D65AU7
About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D65AU7 Schneider Electric price in the box on the right side or send a quick quote.
LC1D65AU7 Product Details
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- [Icw] Rated Short-Time Withstand Current 520 A 104 °F (40 °C) - 10 s power circuit 900 A 104 °F (40 °C) - 1 s power circuit 110 A 104 °F (40 °C) - 10 min power circuit 260 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling cir
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- Motor Power HP (UL / CSA) 40 hp 460/480 V at AC 50/60 Hz for 3 phase 5 hp 115 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 1 phase 20 hp 200/208 V at AC 50/60 Hz for 3 phase 20 hp 230/240 V at AC 50/60 Hz for 3 phase 50 hp 575/600 V at A
- Motor Power Kw 11 kW 400 V AC 50/60 Hz AC-4) 18.5 kW 220...230 V AC 50/60 Hz AC-3) 30 kW 380...400 V AC 50/60 Hz AC-3) 37 kW 500 V AC 50/60 Hz AC-3) 37 kW 660...690 V AC 50/60 Hz AC-3)
- Product Certifications GOST UL CSA CCC
- Control Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
- Utilisation Category AC-4 AC-3 AC-1
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 125 A gG <= 690 V type 1 power circuit 125 A gG <= 690 V type 2 power circuit
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1000 A 440 V power circuit IEC 60947
- Power Dissipation Per Pole 9.6 W AC-1 6.3 W AC-3
- Inrush Power In VA 140 VA 60 Hz 0.75 68 °F (20 °C)) 160 VA 50 Hz 0.75 68 °F (20 °C))
- Mounting Support Rail Plate
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Hold-In Power Consumption In VA 13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
- Contactor Application Motor control Resistive load
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 80 A 140 °F (60 °C) power circuit
- [Ie] Rated Operational Current 80 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 65 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- Electrical Durability 1.4 Mcycles 80 A AC-1 <= 440 V 1.45 Mcycles 65 A AC-3 <= 440 V
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Operating Time 4...19 ms opening 12...26 ms closing
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Heat Dissipation 4…5 W 50/60 Hz
- Signalling Circuit Frequency 25...400 Hz
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Coil Technology Without built-in suppressor module
- Mechanical Durability 6 Mcycles
- Front Cover With
- Average Impedance 1.5 mOhm - Ith 80 A 50 Hz power circuit
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Rated Breaking Capacity 1000 A 440 V power circuit IEC 60947
- Overvoltage Category III
- Auxiliary Contact Composition 1 NO + 1 NC
- Control Circuit Type AC 50/60 Hz
- [Uc] Control Circuit Voltage 240 V AC 50/60 Hz
- Power Pole Contact Composition 3 NO
- Device Short Name LC1D
- Product Or Component Type Contactor
- Product Name TeSys D
- Range TeSys
- Poles Description 3P
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Related documents LC1D65AU7 Specs
This item can ship within 3 days!
1-year warranty
$711.59
LC1D65AU7
Stock:
1
Select Qty:
$711.59
$711.59 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨