Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

LC1D18M7 Schneider Electric Industrial Automation Components

Schneider Electric LC1D18M7 Schneider Electric LC1D18M7, part of the Deca sub-range, is a magnetic contactor designed for screw connections and features three poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within control voltage ranges of 176-242Vac (220Vac nominal; 50Hz) and 187-242Vac (220Vac nominal; 60Hz), with a rated operating voltage (Ue) of up to 690 V. The LC1D18M7 includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). It is capable of handling rated impulse voltage (Uimp) of 6 kV and rated active power ranging from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, under UL/CSA standards. This contactor is designed for mechanical durability of 15 million operations at no load and electrical durability of 1.6 million operations with load, with a phase-to-phase rated voltage of 690 V.
Schneider Electric

Part#:LC1D18M7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1D18M7, part of the Deca sub-range, is a magnetic contactor designed for screw connections and features three poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within control voltage ranges of 176-242Vac (220Vac nominal; 50Hz) and 187-242Vac (220Vac nominal; 60Hz), with a rated operating voltage (Ue) of up to 690 V. The LC1D18M7 includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). It is capable of handling rated impulse voltage (Uimp) of 6 kV and rated active power ranging from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, under UL/CSA standards. This contactor is designed for mechanical durability of 15 million operations at no load and electrical durability of 1.6 million operations with load, with a phase-to-phase rated voltage of 690 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D18M7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    GOST UL RINA CCC DNV BV GL CSA LROS (Lloyds register of shipping)
  • [Icw] Rated Short-Time Withstand Current
    145 A 104 °F (40 °C) - 10 s power circuit 240 A 104 °F (40 °C) - 1 s power circuit 40 A 104 °F (40 °C) - 10 min power circuit 84 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Ui] Rated Insulation Voltage
    Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Motor Power HP (UL / CSA)
    1 hp 115 V at AC 50/60 Hz for 1 phase 3 hp 230/240 V at AC 50/60 Hz for 1 phase 5 hp 200/208 V at AC 50/60 Hz for 3 phase 5 hp 230/240 V at AC 50/60 Hz for 3 phase 10 hp 460/480 V at AC 50/60 Hz for 3 phase 15 hp 575/600 V at AC 5
  • Motor Power Kw
    4 kW 220...230 V AC 50/60 Hz AC-3) 7.5 kW 380...400 V AC 50/60 Hz AC-3) 9 kW 415...440 V AC 50/60 Hz AC-3) 10 kW 500 V AC 50/60 Hz AC-3) 10 kW 660...690 V AC 50/60 Hz AC-3) 4 kW 400 V AC 50/60 Hz AC-4)
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Tightening Torque
    Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lb
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Utilisation Category
    AC-1 AC-4 AC-3
  • Operating Time
    12...22 ms closing 4...19 ms opening
  • Mounting Support
    Plate Rail
  • Electrical Durability
    1.65 Mcycles 18 A AC-3 <= 440 V 1 Mcycles 32 A AC-1 <= 440 V
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Hold-In Power Consumption In VA
    7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Inrush Power In VA
    70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Contactor Application
    Resistive load Motor control
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 32 A 140 °F (60 °C) power circuit
  • [Ie] Rated Operational Current
    18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Power Dissipation Per Pole
    2.5 W AC-1 0.8 W AC-3
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Heat Dissipation
    2…3 W 50/60 Hz
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Coil Technology
    Without built-in suppressor module
  • Mechanical Durability
    15 Mcycles
  • Minimum Switching Voltage
    17 V signalling circuit
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Front Cover
    With
  • Average Impedance
    2.5 mOhm - Ith 32 A 50 Hz power circuit
  • Rated Breaking Capacity
    300 A 440 V power circuit IEC 60947
  • Overvoltage Category
    III
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Control Circuit Type
    AC 50/60 Hz
  • [Uc] Control Circuit Voltage
    220 V AC 50/60 Hz
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys D
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1D
  • Range
    TeSys

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo