LC1D18BD Schneider Electric Automation Components
Part#:LC1D18BD
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 20
Apr 28, 2024
About the product: Schneider Electric - LC1D18BD
About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D18BD Schneider Electric price in the box on the right side or send a quick quote.
LC1D18BD Product Details
- Product Certifications LROS (Lloyds register of shipping) DNV GL RINA BV CCC UL CSA GOST
- Motor Power HP (UL / CSA) 1 hp 115 V at AC 50/60 Hz for 1 phase 3 hp 230/240 V at AC 50/60 Hz for 1 phase 5 hp 200/208 V at AC 50/60 Hz for 3 phase 5 hp 230/240 V at AC 50/60 Hz for 3 phase 10 hp 460/480 V at AC 50/60 Hz for 3 phase 15 hp 575/600 V at AC 5
- [Icw] Rated Short-Time Withstand Current 145 A 104 °F (40 °C) - 10 s power circuit 240 A 104 °F (40 °C) - 1 s power circuit 40 A 104 °F (40 °C) - 10 min power circuit 84 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Motor Power Kw 4 kW 220...230 V AC 50/60 Hz AC-3) 7.5 kW 380...400 V AC 50/60 Hz AC-3) 9 kW 415...440 V AC 50/60 Hz AC-3) 10 kW 500 V AC 50/60 Hz AC-3) 10 kW 660...690 V AC 50/60 Hz AC-3) 4 kW 400 V AC 50/60 Hz AC-4)
- Tightening Torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lb
- Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit
- Control Circuit Voltage Limits 0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Utilisation Category AC-4 AC-1 AC-3
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Ie] Rated Operational Current 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Contactor Application Motor control Resistive load
- Electrical Durability 1.65 Mcycles 18 A AC-3 <= 440 V 1 Mcycles 32 A AC-1 <= 440 V
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 32 A 140 °F (60 °C) power circuit
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Operating Time 53.55...72.45 ms closing 16...24 ms opening
- Mounting Support Plate Rail
- Power Dissipation Per Pole 2.5 W AC-1 0.8 W AC-3
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Hold-In Power Consumption In W 5.4 W 68 °F (20 °C)
- Inrush Power In W 5.4 W 68 °F (20 °C))
- Time Constant 28 ms
- Coil Technology With integral suppression device
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 30 Mcycles
- Front Cover With
- Average Impedance 2.5 mOhm - Ith 32 A 50 Hz power circuit
- Rated Breaking Capacity 300 A 440 V power circuit IEC 60947
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Auxiliary Contact Composition 1 NO + 1 NC
- [Uc] Control Circuit Voltage 24 V DC
- Control Circuit Type DC standard
- Poles Description 3P
- Power Pole Contact Composition 3 NO
- Device Short Name LC1D
- Product Or Component Type Contactor
- Product Name TeSys D
- Range TeSys
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Related documents LC1D18BD Specs
This item can ship within 5 days!
1-year warranty
$81.93
LC1D18BD
Stock:
20
Select Qty:
$81.93
$81.93 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨