Schneider Electric LC1D188D7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 32A (AC-1) and is suitable for DIN rail mounting. The net width of the contactor is 45 mm, and it offers a degree of protection of IP20. The control voltage (AC) ranges from 33.6-46.2Vac at 50Hz (42Vac nominal) and 35.7-46.2Vac at 60Hz (42Vac nominal), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and it boasts a mechanical durability of 15,000,000 operations at no load. The rated voltage (AC) for phase-to-phase is 690 V.
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D188D7 Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Product Certifications DNV RINA GOST CSA GL CCC BV UL LROS (Lloyds register of shipping)
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- [Icw] Rated Short-Time Withstand Current 145 A 104 °F (40 °C) - 10 s power circuit 240 A 104 °F (40 °C) - 1 s power circuit 40 A 104 °F (40 °C) - 10 min power circuit 84 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
- Control Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) connector flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit
- Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Operating Time 12...22 ms closing 4...19 ms opening
- Inrush Power In VA 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
- Hold-In Power Consumption In VA 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mounting Support Plate Rail
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 32 A 140 °F (60 °C) power circuit
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Heat Dissipation 2…3 W 50/60 Hz
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Coil Technology Without built-in suppressor module
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 15 Mcycles
- Minimum Switching Current 5 mA signalling circuit
- Insulation Resistance > 10 MOhm signalling circuit
- Power Dissipation Per Pole 2.5 W AC-1
- Front Cover With
- Electrical Durability 1 Mcycles 32 A AC-1 <= 440 V
- Average Impedance 2.5 mOhm - Ith 32 A 50 Hz power circuit
- Rated Breaking Capacity 300 A 440 V power circuit IEC 60947
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- [Uc] Control Circuit Voltage 42 V AC 50/60 Hz
- Auxiliary Contact Composition 1 NO + 1 NC
- Control Circuit Type AC 50/60 Hz
- [Ie] Rated Operational Current 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Device Short Name LC1D
- Contactor Application Resistive load
- Poles Description 4P
- Power Pole Contact Composition 2 NO + 2 NC
- Utilisation Category AC-1
- Product Or Component Type Contactor
- Product Name TeSys D
- Range TeSys
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents LC1D188D7 Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Schneider Electric
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Schneider Electric Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨