LC1D186BD Schneider Electric Industrial Automation Components

Schneider Electric LC1D186BD Schneider Electric LC1D186BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 18-30Vdc, nominally at 24Vdc. The rated operating voltage (Ue) is up to 690 V, and it features 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. Additionally, it includes 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D186BD is up to 15 million operations at no load, and its electrical durability with load reaches 1.6 million operations. The rated voltage for phase-to-phase connections is 690 V.
Schneider Electric

Part#:LC1D186BD

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 31

Sep 16, 2024

Schneider Electric LC1D186BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 18-30Vdc, nominally at 24Vdc. The rated operating voltage (Ue) is up to 690 V, and it features 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. Additionally, it includes 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D186BD is up to 15 million operations at no load, and its electrical durability with load reaches 1.6 million operations. The rated voltage for phase-to-phase connections is 690 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D186BD Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    LROS (Lloyds register of shipping) RINA DNV GOST BV CSA CCC GL UL
  • [Ui] Rated Insulation Voltage
    Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Motor Power HP (UL / CSA)
    1 hp 115 V at AC 50/60 Hz for 1 phase 3 hp 230/240 V at AC 50/60 Hz for 1 phase 5 hp 200/208 V at AC 50/60 Hz for 3 phase 5 hp 230/240 V at AC 50/60 Hz for 3 phase 10 hp 460/480 V at AC 50/60 Hz for 3 phase 15 hp 575/600 V at AC 5
  • [Icw] Rated Short-Time Withstand Current
    145 A 104 °F (40 °C) - 10 s power circuit 240 A 104 °F (40 °C) - 1 s power circuit 40 A 104 °F (40 °C) - 10 min power circuit 84 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
  • Motor Power Kw
    4 kW 220...230 V AC 50/60 Hz AC-3) 7.5 kW 380...400 V AC 50/60 Hz AC-3) 9 kW 415...440 V AC 50/60 Hz AC-3) 10 kW 500 V AC 50/60 Hz AC-3) 10 kW 660...690 V AC 50/60 Hz AC-3) 4 kW 400 V AC 50/60 Hz AC-4)
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 8 mm M3.5 Power circuit
  • Control Circuit Voltage Limits
    0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit
  • Utilisation Category
    AC-1 AC-4 AC-3
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Operating Time
    53.55...72.45 ms closing 16...24 ms opening
  • Electrical Durability
    1.65 Mcycles 18 A AC-3 <= 440 V 1 Mcycles 32 A AC-1 <= 440 V
  • Contactor Application
    Motor control Resistive load
  • Mounting Support
    Plate Rail
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 32 A 140 °F (60 °C) power circuit
  • [Ie] Rated Operational Current
    18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Power Dissipation Per Pole
    2.5 W AC-1 0.8 W AC-3
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • Minimum Switching Voltage
    17 V signalling circuit
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Inrush Power In W
    5.4 W 68 °F (20 °C))
  • Coil Technology
    With integral suppression device
  • Hold-In Power Consumption In W
    5.4 W 68 °F (20 °C)
  • Time Constant
    28 ms
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Mechanical Durability
    30 Mcycles
  • Front Cover
    With
  • Rated Breaking Capacity
    300 A 440 V power circuit IEC 60947
  • Average Impedance
    2.5 mOhm - Ith 32 A 50 Hz power circuit
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    24 V DC
  • Control Circuit Type
    DC standard
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Power Pole Contact Composition
    3 NO
  • Device Short Name
    LC1D
  • Product Or Component Type
    Contactor
  • Poles Description
    3P
  • Range
    TeSys
  • Product Name
    TeSys D

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



This item can ship within 24h!

1-year warranty

$173.40

Stock:

31

Select Qty:

$173.40

$173.40 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo