Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

LC1D150BD Schneider Electric Automation Components

Schneider Electric LC1D150BD Schneider Electric - LC1D150BD
Schneider Electric

Part#:LC1D150BD

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 5

May 2, 2024

About the product: Schneider Electric - LC1D150BD

About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D150BD Schneider Electric price in the box on the right side or send a quick quote.

LC1D150BD Product Details

  • Motor Power Kw
    40 kW 220...230 V AC 50/60 Hz AC-3) 75 kW 380...400 V AC 50/60 Hz AC-3) 80 kW 415...440 V AC 50/60 Hz AC-3) 90 kW 500 V AC 50/60 Hz AC-3) 100 kW 660...690 V AC 50/60 Hz AC-3) 75 kW 1000 V AC 50/60 Hz AC-3) 22 kW 400 V AC 50/6
  • Product Certifications
    UL BV GL GOST CSA CCC LROS (Lloyds register of shipping) RINA DNV UKCA
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Icw] Rated Short-Time Withstand Current
    250 A 104 °F (40 °C) - 10 min power circuit 580 A 104 °F (40 °C) - 1 min power circuit 1200 A 104 °F (40 °C) - 10 s power circuit 1400 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling c
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
  • Motor Power HP (UL / CSA)
    40 hp 200/208 V at AC 50/60 Hz for 3 phase 50 hp 230/240 V at AC 50/60 Hz for 3 phase 100 hp 460/480 V at AC 50/60 Hz for 3 phase 125 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Control Circuit Voltage Limits
    0.75...1.2 Uc -40…131 °F (-40…55 °C) operational DC 0.15...0.4 Uc -40…158 °F (-40…70 °C) drop-out DC 1...1.2 Uc 131…158 °F (55…70 °C) operational DC
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 315 A gG <= 690 V type 1 power circuit 250 A gG <= 690 V type 2 power circuit
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
  • Utilisation Category
    AC-3 AC-4 AC-1
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)fl
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1660 A 440 V power circuit IEC 60947
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • [Ue] Rated Operational Voltage
    Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
  • Power Dissipation Per Pole
    24 W AC-1 13.5 W AC-3
  • [Ie] Rated Operational Current
    200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 150 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
  • Electrical Durability
    0.85 Mcycles 150 A AC-3 <= 440 V 1 Mcycles 200 A AC-1 <= 440 V
  • Operating Time
    20...35 ms closing 40...75 ms opening
  • Contactor Application
    Resistive load Motor control
  • Mounting Support
    Rail Plate
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Hold-In Power Consumption In W
    2.4…5.1 W 68 °F (20 °C)
  • Time Constant
    25 ms
  • Inrush Power In W
    270…365 W 68 °F (20 °C))
  • Maximum Operating Rate
    1200 cyc/h 140 °F (60 °C)
  • Coil Technology
    With integral suppression device
  • Mechanical Durability
    8 Mcycles
  • Front Cover
    With
  • Average Impedance
    0.6 mOhm - Ith 200 A 50 Hz power circuit
  • Rated Breaking Capacity
    1400 A 440 V power circuit IEC 60947
  • [Ith] Conventional Free Air Thermal Current
    200 A 140 °F (60 °C) power circuit
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • [Uc] Control Circuit Voltage
    24 V DC
  • Control Circuit Type
    DC standard
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Product Name
    TeSys D
  • Product Or Component Type
    Contactor
  • Device Short Name
    LC1D
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


This item can ship within 3 days!

1-year warranty

$343.89

LC1D150BD

Stock:

5

Select Qty:

$343.89

$343.89 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo