LC1D115G7 Schneider Electric Automation components
Part#:LC1D115G7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 26
May 18, 2024
About the product: Schneider Electric - LC1D115G7
About the manufacturer: Schneider Electric is one of the manufacturers that offers Automation components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D115G7 Schneider Electric price in the box on the right side or send a quick quote.
LC1D115G7 Product Details
- Product Certifications LROS (Lloyds register of shipping) DNV CCC GOST GL CSA UL BV RINA UKCA
- Motor Power Kw 30 kW 220...230 V AC 50/60 Hz AC-3) 55 kW 380...400 V AC 50/60 Hz AC-3) 59 kW 415...440 V AC 50/60 Hz AC-3) 75 kW 500 V AC 50/60 Hz AC-3) 80 kW 660...690 V AC 50/60 Hz AC-3) 65 kW 1000 V AC 50/60 Hz AC-3) 18.5 kW 400 V AC 50/
- [Icw] Rated Short-Time Withstand Current 250 A 104 °F (40 °C) - 10 min power circuit 550 A 104 °F (40 °C) - 1 min power circuit 950 A 104 °F (40 °C) - 10 s power circuit 1100 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling ci
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Motor Power HP (UL / CSA) 30 hp 200/208 V at AC 50/60 Hz for 3 phase 40 hp 230/240 V at AC 50/60 Hz for 3 phase 75 hp 460/480 V at AC 50/60 Hz for 3 phase 100 hp 575/600 V at AC 50/60 Hz for 3 phase
- Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)fl
- Control Circuit Voltage Limits 0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz 1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
- Associated Fuse Rating 250 A gG <= 690 V type 1 power circuit 200 A gG <= 690 V type 2 power circuit 10 A gG signalling circuit
- Irms Rated Making Capacity 1260 A 440 V power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
- Utilisation Category AC-1 AC-4 AC-3
- Hold-In Power Consumption In VA 2…18 VA 60 Hz 0.3 68 °F (20 °C)) 2…18 VA 50 Hz 0.3 68 °F (20 °C))
- Inrush Power In VA 280…350 VA 60 Hz 0.8 68 °F (20 °C)) 280…350 VA 50 Hz 0.8 68 °F (20 °C))
- [Ie] Rated Operational Current 200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 115 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Power Dissipation Per Pole 24 W AC-1 7.9 W AC-3
- [Ue] Rated Operational Voltage Power circuit <= 1000 V AC 25...400 Hz Power circuit <= 300 V DC
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Mounting Support Rail Plate
- Electrical Durability 0.8 Mcycles 200 A AC-1 <= 440 V 0.95 Mcycles 115 A AC-3 <= 440 V
- Operating Time 6...20 ms opening 20...50 ms closing
- Contactor Application Resistive load Motor control
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Heat Dissipation 3…8 W 50/60 Hz
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Maximum Operating Rate 2400 cyc/h 60 °C
- Mechanical Durability 8 Mcycles
- Front Cover With
- Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
- Average Impedance 0.6 mOhm - Ith 200 A 50 Hz power circuit
- [Ith] Conventional Free Air Thermal Current 200 A 140 °F (60 °C) power circuit
- Control Circuit Type AC at 50/60 Hz
- Overvoltage Category III
- [Uc] Control Circuit Voltage 120 V AC 50/60 Hz
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
- Auxiliary Contact Composition 1 NO + 1 NC
- Product Or Component Type Contactor
- Product Name TeSys D
- Power Pole Contact Composition 3 NO
- Poles Description 3P
- Device Short Name LC1D
- Range TeSys
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Related documents LC1D115G7 Specs
This item can ship within 24h!
1-year warranty
$418.80
LC1D115G7
Stock:
26
Select Qty:
$418.80
$418.80 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨