Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

PILZ-312890K Pilz Automation Software Solutions

Pilz PILZ-312890K Pilz PILZ-312890K is a Safety I/O unit designed for failsafe operations and includes a safety I/O block module CPU with a real-time clock for time and date functions, offering a resolution of 1s and a deviation of +/- 10s/day, with a buffer time of 10 days. It is equipped with a working memory (RAM) of 128MB and supports FS module bus and FS SNp interface with two SafetyNET p interfaces. These interfaces automatically assign IP addresses in the 169.254.X.Y range and can be set via Automatic SafetyNET p interface, supporting up to 4000 variables with elementary FS data types. The unit features potential isolation between load supply and device supply, as well as between SafetyNET p and device supply, both with functional insulation and a rated surge voltage of 1000V. It is designed for surface mounting, can operate in ambient air temperatures ranging from -30 to +70 °C, and condensation during operation is permitted. The PILZ-312890K measures 260 mm in height, 61.5 mm in width, and 52 mm in depth, with a degree of protection of IP67. It offers a supply voltage range of 19.2-30Vdc (24Vdc nominal) and a rated voltage of 8.2Vdc minimum threshold voltage for signal changes from "1" to "0" and 10Vdc maximum threshold voltage for signal changes from "0" to "1". The maximum cable length between test pulse output and input is 200m. Connection capacity includes 64 x standard connections and 64 x failsafe connections for SafetyNet p, with a power consumption of 4.9 W for the output external power supply (device supply) and 0.2 W for the load supply. It features 16 x digital outputs and 16 x digital inputs, supports a transmission rate of 100MBit/s for SafetyNET, and has a processing time of 0.5-1 ms for input processing and a cycle time of 2-60000 ms for SafetyNET. The connection type includes 8 x 5-pin M12 connectors for I/O ports, 2 x 5-pin M12 connectors for the interface, and 2 x 5-pin M12 (male + female) connectors for power supply, all with screw interlock.
Pilz

Part#:PILZ-312890K

Manufacturer:Pilz

Product Lifecycle:Active

Get a quick Quote!

Pilz PILZ-312890K is a Safety I/O unit designed for failsafe operations and includes a safety I/O block module CPU with a real-time clock for time and date functions, offering a resolution of 1s and a deviation of +/- 10s/day, with a buffer time of 10 days. It is equipped with a working memory (RAM) of 128MB and supports FS module bus and FS SNp interface with two SafetyNET p interfaces. These interfaces automatically assign IP addresses in the 169.254.X.Y range and can be set via Automatic SafetyNET p interface, supporting up to 4000 variables with elementary FS data types. The unit features potential isolation between load supply and device supply, as well as between SafetyNET p and device supply, both with functional insulation and a rated surge voltage of 1000V. It is designed for surface mounting, can operate in ambient air temperatures ranging from -30 to +70 °C, and condensation during operation is permitted. The PILZ-312890K measures 260 mm in height, 61.5 mm in width, and 52 mm in depth, with a degree of protection of IP67. It offers a supply voltage range of 19.2-30Vdc (24Vdc nominal) and a rated voltage of 8.2Vdc minimum threshold voltage for signal changes from "1" to "0" and 10Vdc maximum threshold voltage for signal changes from "0" to "1". The maximum cable length between test pulse output and input is 200m. Connection capacity includes 64 x standard connections and 64 x failsafe connections for SafetyNet p, with a power consumption of 4.9 W for the output external power supply (device supply) and 0.2 W for the load supply. It features 16 x digital outputs and 16 x digital inputs, supports a transmission rate of 100MBit/s for SafetyNET, and has a processing time of 0.5-1 ms for input processing and a cycle time of 2-60000 ms for SafetyNET. The connection type includes 8 x 5-pin M12 connectors for I/O ports, 2 x 5-pin M12 connectors for the interface, and 2 x 5-pin M12 (male + female) connectors for power supply, all with screw interlock.

About the manufacturer: Pilz is one of the manufacturers that offers Automation Software Solutions that you can order at Quotebeam.com. We are at the forefront of driving the evolution of industrial automation. Our company ethos is built on dedication and principles, placing a high priority on safety. Over the years, we have been devoted to creating cutting-edge products and solutions tailored to our customers' requirements.

Check out the PILZ-312890K Pilz price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


PILZ-312890K Description

Pilz PILZ-312890K is a Safety I/O unit designed for failsafe operations and includes a safety I/O block module CPU with a real-time clock for time and date functions, offering a resolution of 1s and a deviation of +/- 10s/day, with a buffer time of 10 days. It is equipped with a working memory (RAM) of 128MB and supports FS module bus and FS SNp interface with two SafetyNET p interfaces. These interfaces automatically assign IP addresses in the 169.254.X.Y range and can be set via Automatic SafetyNET p interface, supporting up to 4000 variables with elementary FS data types. The unit features potential isolation between load supply and device supply, as well as between SafetyNET p and device supply, both with functional insulation and a rated surge voltage of 1000V. It is designed for surface mounting, can operate in ambient air temperatures ranging from -30 to +70 °C, and condensation during operation is permitted. The PILZ-312890K measures 260 mm in height, 61.5 mm in width, and 52 mm in depth, with a degree of protection of IP67. It offers a supply voltage range of 19.2-30Vdc (24Vdc nominal) and a rated voltage of 8.2Vdc minimum threshold voltage for signal changes from "1" to "0" and 10Vdc maximum threshold voltage for signal changes from "0" to "1". The maximum cable length between test pulse output and input is 200m. Connection capacity includes 64 x standard connections and 64 x failsafe connections for SafetyNet p, with a power consumption of 4.9 W for the output external power supply (device supply) and 0.2 W for the load supply. It features 16 x digital outputs and 16 x digital inputs, supports a transmission rate of 100MBit/s for SafetyNET, and has a processing time of 0.5-1 ms for input processing and a cycle time of 2-60000 ms for SafetyNET. The connection type includes 8 x 5-pin M12 connectors for I/O ports, 2 x 5-pin M12 connectors for the interface, and 2 x 5-pin M12 (male + female) connectors for power supply, all with screw interlock.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Pilz

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Pilz Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Pilz Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Pilz, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo