3274005 Phoenix Contact Terminal Blocks
Part#:3274005
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Distribution block, bridged internally, nom. voltage: 450 V, nominal current: 32 A, connection method: Push-in connection, Push-in connection, number of connections: 7, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 27.9 mm, height: 22.7 mm, color:
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3274005 Phoenix Contact price in the box on the right side or send a quick quote.
3274005 Product Details
- Color pink
- Number of levels 1
- Overvoltage category III
- Nominal current IN 57 A
- Open side panel No
- Test spectrum Service life test category 2, bogie-mounted
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock form Half-sine
- Shock duration 18 ms
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Length 28.6 mm
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section AWG min. 20
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 10 mm²
- Connection Feed-in stage
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 7.0 27141120
- Nominal cross section 4 mm²
- Flammability rating according to UL 94 V0
- Rated surge voltage 6 kV
- Insulating material group I
- Nominal voltage UN 450 V
- Oscillation, broadband noise test result Test passed
- ASD level 6.12 (m/s2)2/Hz
- Shock test result Test passed
- Number of shocks per direction 3
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Width 27.9 mm
- Stripping length 12 mm ... 14 mm
- Conductor cross section flexible max. 10 mm²
- Min. AWG conductor cross section, flexible 20
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Value 1 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 6.0 27141100
- Nominal cross section feed-in 10 mm²
- Degree of pollution 3
- Maximum total current 63 A
- Result of thermal test Test passed
- Finger protection guaranteed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height 22.7 mm
- Connection in acc. with standard IEC 60998-2-2
- Conductor cross section flexible min. 0.5 mm²
- Conductor cross section AWG max. 6
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 4 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ETIM 6.0 EC000897
- Operating temperature -35 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 11.0 27141120
- Connection method Push-in connection
- Internal cylindrical gage A4
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 9.0 27141120
- Number of connections 7
- Insulating material PA
- Maximum load current 57 A
- Back of the hand protection guaranteed
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Acceleration 30g
- Test duration per axis 5 h
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section solid max. 16 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm²
- Max. AWG conductor cross section, flexible 8
- Connection cross sections directly pluggable 0.5 mm² 16 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 10.0.1 27141120
- ETIM 7.0 EC000897
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
3274005
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨