3270321 Phoenix Contact Terminal Blocks
Part#:3270321
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Marshalling patchboard, nom. voltage: 500 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 48, number of connections: 288, width: 66 mm, length: 111 mm, color: gray, c
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3270321 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Test duration per axis 5 h
- Number of shocks per direction 3
- Ageing test for screwless modular terminal block temperature cycles 192
- Conductor cross section solid min. 0.34 mm²
- Conductor cross section flexible max. 1.5 mm²
- Result of aging test Test passed
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Length 111 mm
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Connection cross sections directly pluggable 0.34 mm² 2.5 mm² 20 14
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- Maximum power dissipation for nominal condition 0.56 W (the value is based on one connection block and is multiplied according to the pin assignment)
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Test spectrum Service life test category 1, class B, body mounted
- Acceleration 5g
- Shock duration 30 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Conductor cross section solid max. 2.5 mm²
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- ECLASS 10.0.1 27141120
- ECLASS 5.0 27141100
- ECLASS 9.0 27141120
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Connection method Push-in connection
- Connection in acc. with standard IEC 60947-7-1
- Permissible humidity (storage/transport) 30 % ... 70 %
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141120
- ECLASS 5.1 27141100
- Conductor cross section AWG max. 14
- Internal cylindrical gage A1
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.1 27141100
- ECLASS 7.0 27141120
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 6.0 27141100
- ETIM 7.0 EC000897
- Power frequency withstand voltage setpoint 1.89 kV
- Number of positions 48
- Color of connection elements blue
- Rated surge voltage 6 kV
- Insulating material group I
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Number of levels 1
- Insulating material PA
- Conductor cross section AWG min. 26
- Overvoltage category III
- Nominal voltage UN 500 V
- Back of the hand protection guaranteed
- Bending test rotation speed 10 rpm
- Short-time current 0.3 kA
- Result of temperature-rise test Test passed
- Oscillation, broadband noise test result Test passed
- ASD level 0.964 (m/s2)2/Hz
- Shock test result Test passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Stripping length 8 mm ... 10 mm
- Min. AWG conductor cross section, flexible 26
- Max. AWG conductor cross section, flexible 14
- Nominal cross section 1.5 mm²
- Open side panel No
- Result of surge voltage test Test passed
- Result of flexion and pull-out test Test passed
- Result of tight fit on support Test passed
- Setpoint 1 N
- Short circuit stability result Test passed
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Static insulating material application in cold -60 °C
- Height 30 mm
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- UNSPSC 20.0 39121410
- Note The max. load current must not be exceeded by the total current of all connected conductors.
- ETIM 6.0 EC000897
- UNSPSC 18.0 39121410
- UNSPSC 19.0 39121410
- Width 66 mm
- Bending test turns 135
- Result of voltage-drop test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Shock form Half-sine
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Tensile test result Test passed
- Tight fit on carrier NS 35
- Conductor cross section short circuit testing 2.5 mm²
- Color gray
- Maximum load current 24 A (in case of a 2.5 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
- Nominal current IN 17.5 A
- Finger protection guaranteed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Number of connections 288
- Flammability rating according to UL 94 V0
- Degree of pollution 3
- Result of power-frequency withstand voltage test Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Result of thermal test Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Test directions X-, Y- and Z-axis (pos. and neg.)
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨