Ground modular terminal block, connection method: Push-in / plug connection, number of connections: 3, number of positions: 1, cross section: 0.14 mm² - 1.5 mm², AWG: 26 - 14, width: 3.5 mm, height: 37 mm, color: green-yellow, mounting type: NS 35/7,5, NS
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3214725 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Test spectrum Service life test category 1, class B, body mounted
- ASD level 1.857 (m/s2)2/Hz
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- ETIM 4.0 EC000901
- ETIM 6.0 EC000901
- UNSPSC 18.0 39121410
- UNSPSC 19.0 39121410
- Insulating material PA
- Acceleration 5g
- Shock form Half-sine
- Static insulating material application in cold -60 °C
- ETIM 3.0 EC000901
- UNSPSC 6.01 30211811
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- Insulating material group I
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 30 ms
- ECLASS 10.0.1 27141141
- ECLASS 6.0 27141100
- ETIM 7.0 EC000901
- UNSPSC 12.01 39121410
- Open side panel Yes
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Shock test result Test passed
- Height NS 35/7,5 38.5 mm
- ECLASS 4.1 27141100
- ECLASS 7.0 27141141
- ECLASS 9.0 27141141
- UNSPSC 20.0 39121410
- Number of connections 3
- Degree of pollution 3
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test duration per axis 5 h
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection 1 level
- Conductor cross section flexible min. 0.14 mm²
- Internal cylindrical gage A1 / B1
- Connection cross sections directly pluggable 0.25 mm² 1.5 mm²
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 4.0 27141100
- ETIM 2.0 EC000901
- UNSPSC 7.0901 39121410
- UNSPSC 11 39121410
- Rated surge voltage 6 kV
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height 37 mm
- Conductor cross section solid max. 1.5 mm²
- Min. AWG conductor cross section, flexible 26
- Max. AWG conductor cross section, flexible 14
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- End cover width 2.2 mm
- Height NS 35/15 46 mm
- Note Please observe the current carrying capacity of the DIN rails.
- Conductor cross section AWG max. 14
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- Color green-yellow
- Number of positions 1
- Nominal cross section 1.5 mm²
- Overvoltage category III
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Width 3.5 mm
- Connection method Push-in / plug connection
- Conductor cross section AWG min. 26
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 5.1 27141100
- Number of levels 1
- Flammability rating according to UL 94 V0
- Oscillation, broadband noise test result Test passed
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 50.7 mm
- Stripping length 8 mm ... 10 mm
- Conductor cross section solid min. 0.25 mm²
- Connection in acc. with standard CSA
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141141
- ECLASS 5.0 27141100
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨