3214325 Phoenix Contact Terminal Blocks

Phoenix Contact 3214325 Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.14 mm²- 6 mm², AWG: 26 - 10, nominal current: 30 A, nom. voltage: 24 V, width: 6.2 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5, N
Phoenix Contact

Part#:3214325

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 11223

Nov 21, 2024

Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.14 mm²- 6 mm², AWG: 26 - 10, nominal current: 30 A, nom. voltage: 24 V, width: 6.2 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5, N

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3214325 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Fuse
    G / 5 x 20
  • Nominal current IN
    30 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of surge voltage test
    Test passed
  • Insulating material group
    I
  • Number of connections
    4
  • Rated surge voltage
    6 kV
  • Degree of pollution
    3
  • Connection in acc. with standard
    CUL
  • Maximum load current (upper level)
    6.3 A (the current is determined by the fuse used)
  • Open side panel
    No
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test rotation speed
    10 rpm
  • Testing the rated value of the power dissipation (exclusively short circuit protection)
    Test passed
  • Result of temperature-rise test
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height NS 35/7,5
    88.9 mm
  • Conductor cross section solid min.
    0.14 mm²
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.14 mm²
  • ECLASS 5.0
    27141100
  • Note
    Swing the locking lever to its final position before replacing the fuse.
  • Insulating material
    PA
  • Maximum power dissipation for nominal condition
    0.9 W (the value is multiplied when connecting multiple levels)
  • Finger protection
    guaranteed
  • Compatibitity between modular fuse terminal block and fuse insert
    Test passed
  • Actuatiing forces on plug in or lever in fuse insert carriers
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    0.964 (m/s2)2/Hz
  • Shock form
    Half-sine
  • Shock duration
    30 ms
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Height
    94.5 mm
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Internal cylindrical gage
    A4
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27141100
  • ETIM 6.0
    EC000899
  • ETIM 7.0
    EC000899
  • UNSPSC 20.0
    39121410
  • Number of levels
    2
  • Color
    black
  • Rated operating voltage
    250 V
  • Maximum power dissipation
    max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
  • Nominal current IN (upper level)
    6.3 A
  • Fuse type
    Glass / ceramics / ...
  • Contact resistance
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Acceleration
    5g
  • Shock test result
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    92.7 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section AWG max.
    10
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Stripping length
    9 mm
  • Connection method
    Screw connection
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    27141100
  • Nominal cross section
    4 mm²
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Maximum load current
    36 A (the current is determined by the fuse used)
  • Nominal voltage UN
    500 V (the voltage is determined by the fuse used)
  • Back of the hand protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Bending test turns
    135
  • Testing the rated value of the power dissipation (overload and short circuit Protection)
    Test passed
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Test duration per axis
    5 h
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Width
    6.2 mm
  • Height NS 35/15
    96.4 mm
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, stranded min.
    0.14 mm²
  • Screw thread
    M3
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000901
  • UNSPSC 19.0
    39121410
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • 2 conductors with same cross section, solid min.
    0.14 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Tightening torque max
    0.8 Nm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141116
  • UNSPSC 18.0
    39121410
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Tightening torque, min
    0.6 Nm
  • ECLASS 10.0.1
    27141116
  • ECLASS 11.0
    27141116
  • ECLASS 7.0
    27141116
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$11.69

Stock:

11,223

Select Qty:

$11.69

$11.69 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo