Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3214082 Phoenix Contact Terminal Blocks

Phoenix Contact 3214082 Potential collective terminal, In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered., nom. voltage: 1000 V, nominal current: 105 A, connection method: Screw conn
Phoenix Contact

Part#:3214082

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 15

Nov 30, 2024

Potential collective terminal, In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered., nom. voltage: 1000 V, nominal current: 105 A, connection method: Screw conn

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3214082 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Bending test turns
    135
  • Color
    black/yellow
  • Degree of pollution
    2
  • Maximum power dissipation for nominal condition
    4.06 W (the value is multiplied when connecting multiple levels)
  • Maximum load current
    41 A
  • Open side panel
    No
  • Surge voltage test setpoint
    9.8 kV
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Number of connections
    11
  • Insulating material
    PA
  • Insulating material group
    I
  • Nominal voltage UN
    1000 V
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Result of surge voltage test
    Test passed
  • Bending test conductor cross section/weight
    1.5 mm² / 0.4 kg
  • Setpoint
    10 N
  • Requirements, voltage drop
    ≤ 1.6 mV
  • Result of aging test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Acceleration
    30g
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height NS 35/7,5
    48.8 mm
  • ECLASS 10.0.1
    27141120
  • Note
    In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered.
  • Overvoltage category
    III
  • Connection method
    Push-in connection
  • Nominal current IN
    41 A
  • Back of the hand protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Tractive force setpoint
    20 N
  • Result of voltage-drop test
    Test passed
  • Conductor cross section short circuit testing
    50 mm²
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Connection in acc. with standard
    IEC 60947-7-1
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Finger protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Conductor cross section tensile test
    0.5 mm²
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    4.8 kA
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • ASD level
    6.12 (m/s2)2/Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Tightening torque max
    3.7 Nm
  • Two conductors with the same cross section, AWG stranded, max.
    8
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • Shock test result
    Test passed
  • Shock duration
    18 ms
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Tightening torque, min
    3.2 Nm
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • Conductor cross section flexible max.
    2.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section, AWG solid min.
    16
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • ECLASS 5.1
    27141111
  • 2 conductors with same cross section, solid max.
    16 mm²
  • 2 conductors with same cross section, stranded max.
    10 mm²
  • 2 conductors with same cross section, solid min.
    1.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 9.0
    27141120
  • UNSPSC 11
    39121411
  • UNSPSC 21.0
    39121410
  • ETIM 4.0
    EC000897
  • UNSPSC 19.0
    39121410
  • UNSPSC 6.01
    30211812
  • ECLASS 4.0
    27141127
  • UNSPSC 12.01
    39121411
  • UNSPSC 20.0
    39121410
  • Tensile test result
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Tight fit on carrier
    NS 35
  • Test duration per axis
    5 h
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Two conductors with the same cross section, AWG stranded, min.
    16
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • UNSPSC 13.2
    39121411
  • Number of shocks per direction
    3
  • Screw thread
    M6
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 4.1
    27141127
  • ECLASS 6.0
    27141100
  • Height NS 35/15
    56.3 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Oscillation, broadband noise test result
    Test passed
  • Shock form
    Half-sine
  • Width
    16.3 mm
  • Length
    110.4 mm
  • Stripping length
    8 mm ... 10 mm
  • Min. AWG conductor cross section, flexible
    26
  • 2 conductors with same cross section, stranded min.
    1.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    10 mm²
  • Internal cylindrical gage
    B9
  • ECLASS 5.0
    27141127
  • ETIM 3.0
    EC000897
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ETIM 7.0
    EC000897
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section AWG min.
    26
  • Max. AWG conductor cross section, flexible
    14
  • Two conductors with the same cross section, AWG solid max.
    6
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    1.5 mm²
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Short circuit stability result
    Test passed
  • Result of thermal test
    Test passed
  • Conductor cross section solid min.
    0.34 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$36.11

Stock:

15

Select Qty:

$36.11

$36.11 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo