3214082 Phoenix Contact Terminal Blocks
Part#:3214082
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 15
Nov 30, 2024
Potential collective terminal, In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered., nom. voltage: 1000 V, nominal current: 105 A, connection method: Screw conn
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3214082 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Bending test turns 135
- Color black/yellow
- Degree of pollution 2
- Maximum power dissipation for nominal condition 4.06 W (the value is multiplied when connecting multiple levels)
- Maximum load current 41 A
- Open side panel No
- Surge voltage test setpoint 9.8 kV
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Number of connections 11
- Insulating material PA
- Insulating material group I
- Nominal voltage UN 1000 V
- Power frequency withstand voltage setpoint 2.2 kV
- Result of surge voltage test Test passed
- Bending test conductor cross section/weight 1.5 mm² / 0.4 kg
- Setpoint 10 N
- Requirements, voltage drop ≤ 1.6 mV
- Result of aging test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Acceleration 30g
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height NS 35/7,5 48.8 mm
- ECLASS 10.0.1 27141120
- Note In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered.
- Overvoltage category III
- Connection method Push-in connection
- Nominal current IN 41 A
- Back of the hand protection guaranteed
- Result of power-frequency withstand voltage test Test passed
- Bending test rotation speed 10 rpm
- Tractive force setpoint 20 N
- Result of voltage-drop test Test passed
- Conductor cross section short circuit testing 50 mm²
- Ageing test for screwless modular terminal block temperature cycles 192
- Test spectrum Service life test category 2, bogie-mounted
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Number of levels 1
- Flammability rating according to UL 94 V0
- Connection in acc. with standard IEC 60947-7-1
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Finger protection guaranteed
- Result of flexion and pull-out test Test passed
- Conductor cross section tensile test 0.5 mm²
- Result of tight fit on support Test passed
- Result of temperature-rise test Test passed
- Short-time current 4.8 kA
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- ASD level 6.12 (m/s2)2/Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Tightening torque max 3.7 Nm
- Two conductors with the same cross section, AWG stranded, max. 8
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- Shock test result Test passed
- Shock duration 18 ms
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Tightening torque, min 3.2 Nm
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- Two conductors with the same cross section, AWG solid min. 16
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- ECLASS 5.1 27141111
- 2 conductors with same cross section, solid max. 16 mm²
- 2 conductors with same cross section, stranded max. 10 mm²
- 2 conductors with same cross section, solid min. 1.5 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 9.0 27141120
- UNSPSC 11 39121411
- UNSPSC 21.0 39121410
- ETIM 4.0 EC000897
- UNSPSC 19.0 39121410
- UNSPSC 6.01 30211812
- ECLASS 4.0 27141127
- UNSPSC 12.01 39121411
- UNSPSC 20.0 39121410
- Tensile test result Test passed
- Surface flammability NFPA 130 (ASTM E 162) passed
- Tight fit on carrier NS 35
- Test duration per axis 5 h
- Conductor cross section AWG max. 12
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Two conductors with the same cross section, AWG stranded, min. 16
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- UNSPSC 13.2 39121411
- Number of shocks per direction 3
- Screw thread M6
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 4.1 27141127
- ECLASS 6.0 27141100
- Height NS 35/15 56.3 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Oscillation, broadband noise test result Test passed
- Shock form Half-sine
- Width 16.3 mm
- Length 110.4 mm
- Stripping length 8 mm ... 10 mm
- Min. AWG conductor cross section, flexible 26
- 2 conductors with same cross section, stranded min. 1.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 10 mm²
- Internal cylindrical gage B9
- ECLASS 5.0 27141127
- ETIM 3.0 EC000897
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ETIM 7.0 EC000897
- Conductor cross section solid max. 4 mm²
- Conductor cross section AWG min. 26
- Max. AWG conductor cross section, flexible 14
- Two conductors with the same cross section, AWG solid max. 6
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 1.5 mm²
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Short circuit stability result Test passed
- Result of thermal test Test passed
- Conductor cross section solid min. 0.34 mm²
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$36.11
Stock:
15
Select Qty:
$36.11
$36.11 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨