Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3212166 Phoenix Contact Terminal Blocks

Phoenix Contact 3212166 Fuse modular terminal block, fuse type: Flat, connection method: Push-in connection, cross section: 0.5 mm²- 10 mm², AWG: 20 - 8, nominal current: 25 A, nom. voltage: 400 V, width: 8.2 mm, fuse type: Type C / max. 2.2 W, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:3212166

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 30

Nov 28, 2024

Fuse modular terminal block, fuse type: Flat, connection method: Push-in connection, cross section: 0.5 mm²- 10 mm², AWG: 20 - 8, nominal current: 25 A, nom. voltage: 400 V, width: 8.2 mm, fuse type: Type C / max. 2.2 W, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3212166 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Nominal current IN
    25 A (with 4 mm² conductor cross section)
  • Fuse
    Type C / max. 2.2 W
  • Surge voltage test setpoint
    0.91 kV
  • Number of levels
    1
  • Insulating material
    PA
  • Degree of pollution
    3
  • Result of surge voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Color
    black
  • Rated surge voltage
    6 kV
  • Overvoltage category
    III
  • Fuse type
    Flat
  • Finger protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Actuatiing forces on plug in or lever in fuse insert carriers
    Test passed
  • Testing the rated value of the power dissipation (overload and short circuit Protection)
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Result of thermal test
    Test passed
  • ASD level
    0.964 (m/s2)2/Hz
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height
    44 mm
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Number of connections
    2
  • Flammability rating according to UL 94
    V0
  • Rated operating voltage
    48 V
  • Insulating material group
    I
  • Connection in acc. with standard
    IEC 60947-7-3
  • Open side panel
    No
  • Result of tight fit on support
    Test passed
  • Bending test turns
    135
  • Width
    8.2 mm
  • Power frequency withstand voltage setpoint
    1 kV
  • Contact resistance
    Test passed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Test duration per axis
    5 h
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Maximum load current
    30 A (In separate arrangement with 4 mm² conductor cross section)
  • Bending test rotation speed
    10 rpm
  • Result of flexion and pull-out test
    Test passed
  • Testing the rated value of the power dissipation (exclusively short circuit protection)
    Test passed
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Nominal voltage UN
    400 V
  • Back of the hand protection
    guaranteed
  • Compatibitity between modular fuse terminal block and fuse insert
    Test passed
  • Temperature cycles
    192
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Acceleration
    5g
  • Shock test result
    Test passed
  • Shock duration
    30 ms
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Height NS 35/7,5
    45.5 mm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Conductor cross section solid min.
    0.5 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm² When using TWIN ferrules, we recommend a minimum ferrule length of 13 mm.
  • ECLASS 4.1
    27141100
  • ECLASS 5.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 3.0
    EC000899
  • UNSPSC 11
    39121410
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410
  • Result of aging test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Length
    74.1 mm
  • Height NS 35/15
    53 mm
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section AWG min.
    20
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • ECLASS 10.0.1
    27141116
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141116
  • ETIM 4.0
    EC000899
  • ETIM 2.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 13.2
    39121410
  • UNSPSC 19.0
    39121410
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section AWG max.
    8
  • Stripping length
    10 mm ... 12 mm
  • Connection method
    Push-in connection
  • Internal cylindrical gage
    A5
  • ECLASS 4.0
    27141100
  • ECLASS 11.0
    27141116
  • ECLASS 7.0
    27141116
  • ETIM 7.0
    EC000899
  • ETIM 6.0
    EC000899
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Maximum power dissipation for nominal condition
    1.31 W
  • Nominal cross section
    6 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$14.89

Stock:

30

Select Qty:

$14.89

$14.89 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo