Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3072803 Phoenix Contact Terminal Blocks

Phoenix Contact 3072803 Disconnect terminal block, connection method: Screw connection, cross section: 0.5 mm² - 10 mm² , AWG: 20 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray
Phoenix Contact

Part#:3072803

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Disconnect terminal block, connection method: Screw connection, cross section: 0.5 mm² - 10 mm² , AWG: 20 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3072803 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of connections
    2
  • Insulating material
    PA
  • Connection in acc. with standard
    IEC 60947-7-1
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Result of voltage-drop test
    Test passed
  • Short-time current
    1.2 kA
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Number of levels
    1
  • Nominal cross section
    6 mm²
  • Nominal current IN
    41 A
  • Nominal voltage UN
    500 V
  • Back of the hand protection
    guaranteed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Color
    gray
  • Degree of pollution
    3
  • Insulating material group
    I
  • Maximum power dissipation for nominal condition
    1.31 W
  • Surge voltage test setpoint
    7.3 kV
  • Result of flexion and pull-out test
    Test passed
  • Tractive force setpoint
    90 N
  • Result of temperature-rise test
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    55.5 mm
  • Conductor cross section solid min.
    0.5 mm²
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    4 mm²
  • Tightening torque max
    1.6 Nm
  • ECLASS 10.0.1
    27141126
  • Rated surge voltage
    6 kV
  • Overvoltage category
    III
  • Open side panel
    Yes
  • Power frequency withstand voltage setpoint
    2 kV
  • Bending test rotation speed
    10 rpm
  • Conductor cross section tensile test
    10 mm²
  • Tight fit on carrier
    NS 32/NS 35
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • End cover width
    2.2 mm
  • Note
    Terminal point
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, stranded min.
    0.5 mm²
  • Connection method
    Screw connection
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141100
  • ETIM 6.0
    EC000902
  • UNSPSC 19.0
    39121410
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    57 A (with 10 mm² conductor cross section)
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Tensile test result
    Test passed
  • Requirements, voltage drop
    ≤ 6,4 mV
  • Conductor cross section short circuit testing
    10 mm²
  • Result of thermal test
    Test passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    8.2 mm
  • Height NS 32
    53 mm
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, solid min.
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    2.5 mm²
  • Stripping length
    10 mm
  • Screw thread
    M4
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27141100
  • ECLASS 5.1
    27141100
  • ECLASS 9.0
    27141126
  • ETIM 7.0
    EC000902
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410
  • Bending test turns
    135
  • Result of tight fit on support
    Test passed
  • Setpoint
    5 N
  • Short circuit stability result
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    48 mm
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Internal cylindrical gage
    A5
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 11.0
    27141126
  • ECLASS 6.0
    27141100
  • ETIM 2.0
    EC000902
  • UNSPSC 20.0
    39121410
  • Length
    66.5 mm
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section AWG min.
    20
  • 2 conductors with same cross section, stranded max.
    4 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.5 mm²
  • Tightening torque, min
    1.5 Nm
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27141100
  • ETIM 3.0
    EC000902
  • ETIM 4.0
    EC000902
  • ECLASS 7.0
    27141126
  • UNSPSC 18.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo