Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

3072801 Phoenix Contact Terminal Blocks

Phoenix Contact 3072801 Feed-through terminal block, connection method: Screw connection, cross section: 0.5 mm² - 10 mm² , AWG: 20 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray
Phoenix Contact

Part#:3072801

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Feed-through terminal block, connection method: Screw connection, cross section: 0.5 mm² - 10 mm² , AWG: 20 - 10, width: 8.2 mm, mounting type: NS 35/7,5, NS 35/15, NS 32, color: gray

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3072801 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Note
    Terminal point
  • Stripping length
    10 mm
  • UNSPSC 13.2
    39121410
  • Internal cylindrical gage
    A5
  • Potentials
    1
  • Nominal voltage UN
    800 V
  • Result of surge voltage test
    Test passed
  • Length
    66.5 mm
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    1.31 W
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Surge voltage test setpoint
    7.2 kV
  • Insulating material
    PA
  • Overvoltage category
    III
  • Color
    gray
  • Number of connections
    2
  • UNSPSC 20.0
    39121410
  • 2 conductors with same cross section, stranded min.
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.5 mm²
  • ECLASS 10.0.1
    27141120
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27141100
  • ETIM 6.0
    EC000897
  • UNSPSC 19.0
    39121410
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 7.0
    27141120
  • ECLASS 6.0
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410
  • UNSPSC 21.0
    39121410
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ETIM 3.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Rated surge voltage
    6 kV
  • Maximum load current
    57 A (with 10 mm² conductor cross section)
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Tensile test result
    Test passed
  • Result of temperature-rise test
    Test passed
  • Degree of pollution
    3
  • Static insulating material application in cold
    -60 °C
  • Number of levels
    1
  • Finger protection
    guaranteed
  • Bending test turns
    135
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section AWG min.
    20
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • Result of voltage-drop test
    Test passed
  • Short-time current
    0.72 kA
  • ASD level
    6.12 (m/s2)2/Hz
  • Width
    8.2 mm
  • Connection
    1 level
  • Nominal cross section
    6 mm²
  • Nominal current IN
    41 A
  • Power frequency withstand voltage setpoint
    2 kV
  • Tractive force setpoint
    90 N
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Acceleration
    30g
  • Min. AWG conductor cross section, flexible
    20
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • ECLASS 5.0
    27141100
  • Shock duration
    18 ms
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    48 mm
  • Tightening torque, min
    1.5 Nm
  • Conductor cross section solid max.
    10 mm²
  • Insulating material group
    I
  • Short circuit stability result
    Test passed
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Height NS 35/15
    55.5 mm
  • Screw thread
    M4
  • Conductor cross section solid min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Back of the hand protection
    guaranteed
  • Bending test rotation speed
    10 rpm
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Requirements, voltage drop
    U1 ≤ 3,2 mVU2 ≤ 1,5 x U1dT ≤ 45 K
  • Conductor cross section short circuit testing
    6 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Test duration per axis
    5 h
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Max. AWG conductor cross section, flexible
    10
  • REACh SVHC
    Lead 7439-92-1
  • Connection method
    Screw connection
  • Tightening torque max
    1.6 Nm
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Height NS 32
    53 mm
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section AWG max.
    8
  • Tight fit on carrier
    NS 32/NS 35
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • 2 conductors with same cross section, solid min.
    0.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Result of flexion and pull-out test
    Test passed
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Open side panel
    Yes
  • Conductor cross section tensile test
    10 mm²
  • ECLASS 9.0
    27141120
  • ECLASS 4.0
    27141100
  • ECLASS 4.1
    27141100
  • ETIM 7.0
    EC000897
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    2.5 mm²
  • UNSPSC 6.01
    30211811
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    4 mm²
  • ETIM 4.0
    EC000902
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • 2 conductors with same cross section, stranded max.
    4 mm²

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo