3072190 Phoenix Contact Terminal Blocks
Part#:3072190
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.2 mm²- 4 mm², AWG: 24 - 12, nominal current: 6.3 A, nom. voltage: 800 V, width: 8.2 mm, fuse type: G / 5 x 20 / 5 x 25 / 5 x 30, mounting
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3072190 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Oscillation, broadband noise test result Test passed
- Acceleration 5g
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Width 8.2 mm
- Conductor cross section solid max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm²
- Cross section with insertion bridge, stranded max. 4 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Stripping length 8 mm
- Screw thread M3
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 4.0 27141100
- ECLASS 5.1 27141100
- ETIM 2.0 EC000897
- ETIM 6.0 EC000899
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- Testing the rated value of the power dissipation (exclusively short circuit protection) Test passed
- ASD level 1.857 (m/s2)2/Hz
- Shock test result Test passed
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section flexible max. 4 mm²
- Result of temperature-rise test Test passed
- Test spectrum Service life test category 1, class B, body mounted
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 30 ms
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/7,5 56.5 mm
- Height NS 32 61.5 mm
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Conductor cross section AWG max. 12
- 2 conductors with same cross section, stranded min. 0.2 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Connection method Screw connection
- Tightening torque, min 0.6 Nm
- ECLASS 10.0.1 27141116
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27141100
- ETIM 3.0 EC000899
- UNSPSC 6.01 30211811
- UNSPSC 18.0 39121410
- Bending test turns 135
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Test duration per axis 5 h
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 64 mm
- Conductor cross section flexible min. 0.2 mm²
- Cross section with insertion bridge, solid max. 4 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 9.0 27141116
- UNSPSC 7.0901 39121410
- UNSPSC 19.0 39121410
- Testing the rated value of the power dissipation (overload and short circuit Protection) Test passed
- Result of thermal test Test passed
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Shock form Half-sine
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Length 72.5 mm
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- 2 conductors with same cross section, solid min. 0.2 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.1 27141100
- ECLASS 7.0 27141116
- ETIM 7.0 EC000899
- UNSPSC 12.01 39121410
- 2 conductors with same cross section, solid max. 1.5 mm²
- Internal cylindrical gage A4
- Tightening torque max 0.8 Nm
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141116
- ECLASS 6.0 27141100
- ETIM 4.0 EC000899
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
- Maximum load current 6.3 A
- Flammability rating according to UL 94 V2
- Overvoltage category III
- Nominal voltage UN 800 V (As a fuse terminal block)
- Finger protection guaranteed
- Power frequency withstand voltage setpoint 2 kV
- Number of levels 1
- Nominal cross section 4 mm²
- Rated operating voltage 250 V
- Note Swing the locking lever to its final position before replacing the fuse.
- Insulating material PA
- Nominal current IN 6.3 A
- Open side panel No
- Surge voltage test setpoint 9.8 kV
- Result of flexion and pull-out test Test passed
- Number of connections 2
- Maximum power dissipation for nominal condition 1.02 W
- Rated surge voltage 8 kV
- Insulating material group I
- Fuse type Glass / ceramics / ...
- Result of surge voltage test Test passed
- Compatibitity between modular fuse terminal block and fuse insert Test passed
- Actuatiing forces on plug in or lever in fuse insert carriers Test passed
- Color yellow
- Degree of pollution 3
- Connection in acc. with standard CSA
- Fuse G / 5 x 20 / 5 x 25 / 5 x 30
- Back of the hand protection guaranteed
- Result of tight fit on support Test passed
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of power-frequency withstand voltage test Test passed
- Contact resistance Test passed
- Bending test rotation speed 10 rpm
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test conductor cross section/weight 0.2 mm² / 0.2 kg
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.