Phoenix Contact 3010110 High-current terminal block, nom. voltage: 1000 V, nominal current: 309 A, connection method: Screw connection, number of connections: 2, cross section: 35 mm² - 150 mm², AWG: 2 - 300 kcmil, width: 31 mm, height: 107.3 mm, color: gray, mounting type: NS 3
Phoenix Contact

Part#:3010110

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 12

Nov 8, 2024

High-current terminal block, nom. voltage: 1000 V, nominal current: 309 A, connection method: Screw connection, number of connections: 2, cross section: 35 mm² - 150 mm², AWG: 2 - 300 kcmil, width: 31 mm, height: 107.3 mm, color: gray, mounting type: NS 3

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3010110 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Shock duration
    18 ms
  • Open side panel
    No
  • Nominal cross section
    150 mm²
  • Maximum power dissipation for nominal condition
    9.55 W
  • Nominal current IN
    309 A
  • Tensile test result
    Test passed
  • Number of connections
    2
  • Max. AWG conductor cross section, flexible
    300 kcmil
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    50 mm²
  • Cross section with insertion bridge, stranded max.
    120 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 125°C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141100
  • ECLASS 7.0
    27141120
  • Flammability rating according to UL 94
    V0
  • Number of levels
    1
  • Insulating material
    PA
  • Degree of pollution
    3
  • Nominal voltage UN
    1000 V
  • Height NS 32
    116 mm
  • Stripping length
    40 mm
  • Conductor cross section solid min.
    35 mm²
  • UNSPSC 6.01
    30211811
  • ETIM 4.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    50 mm²
  • Overvoltage category
    III
  • Insulating material group
    I
  • Back of the hand protection
    guaranteed
  • Screw thread
    M10
  • Conductor cross section solid max.
    150 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    50 mm²
  • 2 conductors with same cross section, solid max.
    50 mm²
  • Result of surge voltage test
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Height NS 35/15
    118.5 mm
  • Tightening torque, min
    25 Nm
  • Conductor cross section flexible min.
    50 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    150 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    25 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141100
  • ETIM 6.0
    EC000897
  • UNSPSC 18.0
    39121410
  • Potentials
    1
  • Rated surge voltage
    8 kV
  • UNSPSC 19.0
    39121410
  • Color
    gray
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • Connection in acc. with standard
    CSA
  • Conductor cross section AWG max.
    300 kcmil
  • Min. AWG conductor cross section, flexible
    1/0
  • 2 conductors with same cross section, solid min.
    25 mm²
  • 2 conductors with same cross section, stranded max.
    50 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • Maximum load current
    309 A (with 150 mm² conductor cross section)
  • ECLASS 11.0
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 20.0
    39121410
  • Height
    107.3 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    150 mm²
  • Cross section with insertion bridge, solid max.
    150 mm²
  • 2 conductors with same cross section, stranded min.
    35 mm²
  • Internal cylindrical gage
    B14
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • UNSPSC 11
    39121410
  • Connection method
    Screw connection
  • Tightening torque max
    30 Nm
  • Conductor cross section AWG min.
    2
  • UNSPSC 21.0
    39121410
  • Conductor cross section flexible max.
    150 mm²
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • Static insulating material application in cold
    -60 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Length
    100 mm
  • Surge voltage test setpoint
    9.8 kV
  • Result of flexion and pull-out test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Result of thermal test
    Test passed
  • Test duration per axis
    5 h
  • ASD level
    6.12 (m/s2)2/Hz
  • Number of shocks per direction
    3
  • Acceleration
    30g
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Bending test turns
    135
  • Conductor cross section short circuit testing
    150 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • UNSPSC 13.2
    39121410
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Result of voltage-drop test
    Test passed
  • Short-time current
    18 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    31 mm
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 32/NS 35
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock form
    Semi-sinusoidal
  • Short circuit stability result
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • ECLASS 10.0.1
    27141120
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$102.71

Stock:

12

Select Qty:

$102.71

$102.71 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo