3007217 Phoenix Contact Terminal Blocks

Phoenix Contact 3007217 Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.2 mm²- 4 mm², AWG: 24 - 12, nominal current: 32 A, nom. voltage: 400 V, width: 8.2 mm, fuse type: G / 6,3 x 32, mounting type: NS 35/7,5,
Phoenix Contact

Part#:3007217

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 25

Nov 22, 2024

Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection, cross section: 0.2 mm²- 4 mm², AWG: 24 - 12, nominal current: 32 A, nom. voltage: 400 V, width: 8.2 mm, fuse type: G / 6,3 x 32, mounting type: NS 35/7,5,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3007217 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of connections
    4
  • Rated surge voltage
    6 kV
  • Maximum load current
    32 A (Lower level)
  • Connection in acc. with standard
    CSA
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Result of thermal test
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    79 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Connection method
    Screw connection
  • Number of levels
    2
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Fuse
    G / 6,3 x 32
  • Finger protection
    guaranteed
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    86.5 mm
  • Height NS 32
    84 mm
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Cross section with insertion bridge, stranded max.
    2.5 mm²
  • Stripping length
    8 mm
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Nominal cross section
    4 mm²
  • Maximum power dissipation for nominal condition
    1.02 W (the value is multiplied when connecting multiple levels)
  • Nominal current IN
    32 A
  • Maximum load current (upper level)
    10 A
  • Fuse type
    Glass / ceramics / ...
  • Actuatiing forces on plug in or lever in fuse insert carriers
    Test passed
  • Insulating material group
    I
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Color
    black
  • Degree of pollution
    3
  • Maximum power dissipation
    max. 2.5 W (with single arrangement of the fuse terminal block in the event of overload)
  • Open side panel
    No
  • Result of surge voltage test
    Test passed
  • Compatibitity between modular fuse terminal block and fuse insert
    Test passed
  • Width
    8.2 mm
  • Note
    In the closed condition.
  • Insulating material
    PA
  • Nominal current IN (upper level)
    10 A
  • Testing the rated value of the power dissipation (exclusively short circuit protection)
    Test passed
  • Conductor cross section AWG min.
    24
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Internal cylindrical gage
    A4
  • Screw thread
    M3
  • ECLASS 4.0
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 6.0
    EC000899
  • UNSPSC 13.2
    39121410
  • UNSPSC 20.0
    39121410
  • Nominal voltage UN
    400 V
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Tightening torque max
    0.8 Nm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141116
  • ECLASS 5.1
    27141100
  • ETIM 2.0
    EC000897
  • ETIM 7.0
    EC000899
  • UNSPSC 12.01
    39121410
  • Bending test turns
    135
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Conductor cross section solid max.
    4 mm²
  • Cross section with insertion bridge, solid max.
    4 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 9.0
    27141116
  • UNSPSC 11
    39121410
  • UNSPSC 19.0
    39121410
  • Back of the hand protection
    guaranteed
  • Contact resistance
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • ECLASS 10.0.1
    27141116
  • ECLASS 5.0
    27141100
  • ETIM 3.0
    EC000899
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410
  • Testing the rated value of the power dissipation (overload and short circuit Protection)
    Test passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    86.5 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Tightening torque, min
    0.5 Nm
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27141116
  • ETIM 4.0
    EC000899
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

25

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo