3003363 Phoenix Contact Terminal Blocks
Part#:3003363
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Micro terminal, nom. voltage: 400 V, nominal current: 17.5 A, connection method: Screw connection, number of connections: 2, cross section: 0.14 mm² - 1.5 mm², AWG: 26 - 16, width: 4.2 mm, color: blue, mounting type: NS 15
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3003363 Phoenix Contact price in the box on the right side or send a quick quote.
3003363 Product Details
- Width 4.2 mm
- Connection 1 level
- Min. AWG conductor cross section, flexible 26
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Tightening torque, min 0.22 Nm
- Conductor cross section flexible max. 1.5 mm²
- Screw thread M2
- Conductor cross section solid max. 1.5 mm²
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Connection method Screw connection
- Stripping length 6 mm
- Tightening torque max 0.25 Nm
- Conductor cross section flexible, with ferrule with plastic sleeve max. 0.75 mm²
- ETIM 2.0 EC000897
- Length 22 mm
- ETIM 6.0 EC000897
- UNSPSC 21.0 39121410
- Conductor cross section AWG min. 26
- ECLASS 5.0 27141100
- ECLASS 7.0 27141120
- UNSPSC 12.01 39121410
- UNSPSC 20.0 39121410
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid min. 0.14 mm²
- ECLASS 5.1 27141100
- ETIM 3.0 EC000897
- Conductor cross section solid min. 0.14 mm²
- Max. AWG conductor cross section, flexible 16
- Ambient temperature (assembly) -5 °C ... 70 °C
- ETIM 7.0 EC000897
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 4.0 27141100
- ECLASS 9.0 27141120
- UNSPSC 6.01 30211811
- UNSPSC 19.0 39121410
- UNSPSC 18.0 39121410
- Number of levels 1
- Insulating material group I
- Degree of pollution 3
- Result of flexion and pull-out test Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Tensile test result Test passed
- Short circuit stability result Test passed
- Result of thermal test Test passed
- Surface flammability NFPA 130 (ASTM E 162) passed
- Conductor cross section flexible, with ferrule without plastic sleeve max. 0.75 mm²
- Potentials 1
- Insulating material PA
- Maximum power dissipation for nominal condition 0.56 W
- Nominal voltage UN 400 V
- Back of the hand protection guaranteed
- 2 conductors with same cross section, stranded min. 0.14 mm²
- 2 conductors with same cross section, solid max. 0.5 mm²
- Internal cylindrical gage A1
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27141100
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 0.34 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- Number of connections 2
- Color blue
- Overvoltage category III
- Finger protection guaranteed
- Open side panel Yes
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test turns 135
- Setpoint 1 N
- Short-time current 0.18 kA
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- ECLASS 11.0 27141120
- ECLASS 4.1 27141100
- ETIM 4.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 13.2 39121410
- Nominal cross section 1.5 mm²
- Flammability rating according to UL 94 V0
- Rated surge voltage 4 kV
- Nominal current IN 17.5 A
- Result of surge voltage test Test passed
- Result of power-frequency withstand voltage test Test passed
- Bending test rotation speed 10 rpm
- Tight fit on carrier NS 15
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- 2 conductors with same cross section, stranded max. 0.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 10.0.1 27141120
- Shock protection test specification IEC 60529:2001-02
- Power frequency withstand voltage setpoint 1.89 kV
- Result of tight fit on support Test passed
- Result of temperature-rise test Test passed
- Conductor cross section short circuit testing 1.5 mm²
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Height NS 15 23.5 mm
- End cover width 1 mm
- Connection in acc. with standard CSA
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section AWG max. 16
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Result of voltage-drop test Test passed
- UNSPSC 11 39121410
- Maximum load current 17.5 A (with 1.5 mm² conductor cross section)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
3003363
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨