Pick-off terminal block, Can only be used in conjunction with UKH 50/70, nom. voltage: 1000 V, nominal current: 57 A, connection method: Screw connection, number of connections: 1, cross section: 0.5 mm² - 10 mm², AWG: 20 - 8, width: 10.2 mm, height: 34.7
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3001763 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ETIM 2.0 EC000901
- UNSPSC 20.0 39121402
- ECLASS 10.0.1 27141151
- Insulating material PA
- Degree of pollution 3
- Static insulating material application in cold -60 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Conductor cross section solid max. 10 mm²
- Conductor cross section flexible max. 10 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 2.5 mm²
- Tightening torque, min 1.5 Nm
- ECLASS 5.0 27141100
- Ambient temperature (assembly) -5 °C ... 70 °C
- Note Can only be used in conjunction with UKH 50/70
- Flammability rating according to UL 94 V0
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Nominal voltage UN 1000 V
- Surface flammability NFPA 130 (ASTM E 162) passed
- Length 20.7 mm
- Conductor cross section flexible min. 0.5 mm²
- Conductor cross section AWG max. 8
- 2 conductors with same cross section, stranded min. 0.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 6 mm²
- Stripping length 10 mm
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- ECLASS 7.0 27141151
- Nominal cross section 10 mm²
- Nominal current IN 57 A
- Open side panel No
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Conductor cross section AWG min. 20
- Conductor cross section flexible, with ferrule without plastic sleeve max. 10 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.5 mm²
- Connection method Screw connection
- Tightening torque max 1.8 Nm
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27141100
- ECLASS 9.0 27141151
- ETIM 7.0 EC002021
- UNSPSC 12.01 39121402
- Overvoltage category III
- Insulating material group I
- Maximum load current 57 A (with 10 mm² conductor cross section)
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- 2 conductors with same cross section, stranded max. 4 mm²
- 2 conductors with same cross section, solid max. 4 mm²
- Internal cylindrical gage B6
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 11.0 27141151
- ECLASS 6.0 27141100
- ETIM 4.0 EC000901
- Color gray
- Rated surge voltage 8 kV
- Maximum power dissipation for nominal condition 1.82 W
- Connection in acc. with standard CSA
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Width 10.2 mm
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- 2 conductors with same cross section, solid min. 0.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Permissible humidity (storage/transport) 30 % ... 70 %
- ETIM 3.0 EC000901
- UNSPSC 19.0 39121402
- UNSPSC 11 39121402
- UNSPSC 18.0 39121402
- ECLASS 4.1 27141100
- UNSPSC 7.0901 39121402
- UNSPSC 6.01 30211802
- ETIM 6.0 EC002021
- UNSPSC 21.0 39121402
- UNSPSC 13.2 39121402
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨